Glomerular filtration rate estimation by use of a correction formula for slope-intercept plasma iohexol clearance in cats

被引:22
|
作者
Finch, Natalie C. [1 ]
Syme, Harriet M. [1 ]
Elliott, Jonathan [1 ]
Peters, Adrien M. [2 ]
Gerritsen, Robert [3 ]
Croubels, Siska [4 ]
Heiene, Reidun [5 ]
机构
[1] Univ London, Royal Vet Coll, London NW1 0TU, England
[2] Royal Sussex Cty Hosp, Brighton BN2 5BE, E Sussex, England
[3] Referral Clin De Kompaan, Ommen, Netherlands
[4] Univ Ghent, Fac Vet Med, B-9000 Ghent, Belgium
[5] Norwegian Sch Vet Sci, N-0033 Oslo, Norway
关键词
EXOGENOUS CREATININE CLEARANCE; HEALTHY CATS; ENDO-IOHEXOL; EXO-IOHEXOL; DOGS; PHARMACOKINETICS; AGENT; ACID;
D O I
10.2460/ajvr.72.12.1652
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To develop a formula for correcting slope-intercept plasma iohexol clearance in cats and to compare clearance of total iohexol (Tlox), endo-iohexol (Enlox), and exo-iohexol (Exlox). Animals-20 client-owned, healthy adult and geriatric cats. Procedures-Plasma clearance of Tlox was determined via multisample and slope-intercept methods. A multisample method was used to determine clearance for Enlox and Exlox. A second-order polynomial correction factor was derived by performing regression analysis of the multisample data with the slope-intercept data and forcing the regression line though the origin. Clearance corrected by use of the derived formula was compared with clearance corrected by use of Brochner-Mortensen human and Heiene canine formulae. Statistical testing was applied, and Bland-Altman plots were created to assess the degree of agreement between Tlox, Enlox, and Exlox clearance. Results-Mean +/- SD iohexol clearance estimated via multisample and corrected slope-intercept methods was 2.16 +/- 0.35 mL/min/kg and 2.14 +/- 0.34 mL/min/kg, respectively. The derived feline correction formula was Cl(corrected) = (1.036 X Cl(uncorrected)) (0.062 X Cl(uncorrected)(2)), in which Cl represents clearance. Results obtained by use of the 2 methods were in excellent agreement. Clearance corrected by use of the Heiene formula had a linear relationship with clearance corrected by use of the feline formula; however, the relationship of the feline formula with the Brochner-Mortensen formula was nonlinear. Agreement between Tlox, Enlox, and Exlox clearance was excellent. Conclusions and Clinical Relevance-The derived feline correction formula applied to slope-intercept plasma iohexol clearance accurately predicted multisample clearance in cats. Use of this technique offers an important advantage by reducing stress to cats associated with repeated blood sample collection and decreasing the costs of analysis. (Am J Vet Res 2011;72:1652-1659)
引用
收藏
页码:1652 / 1659
页数:8
相关论文
共 50 条
  • [1] Correction of the slope-intercept method for the measurement of glomerular filtration rate
    Blake, Glen M.
    Barnfield, Mark C.
    Burniston, Maria T.
    Fleming, John S.
    Cosgriff, Philip S.
    Siddique, Musib
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (12) : 1277 - 1283
  • [2] Use of plasma clearance of iohexol for estimating glomerular filtration rate in cats
    Miyamoto, K
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (04) : 572 - 575
  • [3] Commentary to 'Correction of the slope-intercept method for the measurement of glomerular filtration rate'
    Jodal, Lars
    Brochner-Mortensen, Jens
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (04) : 407 - 408
  • [4] Calculating the precision of slope-intercept glomerular filtration rate measurements
    Memmott, Matthew J.
    Lawson, Richard S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (08) : 959 - 966
  • [5] Correction of slope-intercept glomerular filtration rate measurement without scaling for body size
    McMeekin, Helena
    Burniston, Maria T.
    Barnfield, Mark
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (01) : 68 - 72
  • [6] Robustness of slope-intercept versus slope-only for measurement of glomerular filtration rate
    Peters, AM
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) : 115 - 117
  • [7] Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) : 1086 - 1092
  • [8] Errors in measurement of glomerular filtration rate using the slope-intercept technique and their identification
    Oliveira, Ana
    Conway, Lauren
    Heraghty, Neil
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2024, 45 (01) : 51 - 60
  • [9] Comparison of slope-intercept with single plasma sample methods in estimating glomerular filtration rate using radionuclides
    Osman, Abdelbagi Omer
    Elmadani, Ahmed Elkhidir
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2014, 25 (02) : 321 - 325
  • [10] Robustness of slope-intercept versus slope-only for measurement of glomerular filtration rate - Reply
    De Sadeleer, C
    Piepsz, A
    Ham, HR
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) : 117 - 117