Brain PET and functional MRI: why simultaneously using hybrid PET/MR systems?

被引:19
|
作者
Cechin, Diego [1 ,2 ]
Palombit, Alessandro [2 ,3 ]
Castelaro, Marco [2 ,3 ]
Silvestri, Erica [2 ,3 ]
Bui, Franco [1 ]
Barthel, Henryk [4 ]
Sabri, Osama [4 ]
Corbetta, Maurizio [2 ,5 ]
Bertoldo, Alessandra [2 ,3 ]
机构
[1] Univ Hosp Padua, Dept Med DIMED, Nucl Med Unit, Via Giustiniani 2, I-35128 Padua, Italy
[2] Univ Padua, Padua Neurosci Ctr, Padua, Italy
[3] Univ Padua, Dept Informat Engn, Padua, Italy
[4] Univ Leipzig, Dept Nucl Med, Leipzig, Germany
[5] Univ Padua, Dept Neurosci, Padua, Italy
关键词
Magnetic resonance imaging; Positron-emission tomography; Sensory receptor cells; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; RESTING HUMAN BRAIN; GLUCOSE-METABOLISM; INPUT FUNCTION; MOTION CORRECTION; CONNECTIVITY; PERFUSION; SCANNER; QUANTIFICATION;
D O I
10.23736/S1824-4785.17.03008-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
INTRODUCTION: In the last 20 years growing attention has been devoted to multimodal imaging. The recent literature is rich of clinical and research studies that have been performed using different imaging modalities on both separate and integrated positron emission tomography (PET) and magnetic resonance (MR) scanners. However, today, hybrid PET/MR systems measure signals related to brain structure, metabolism, neurochemistry, perfusion, and neuronal activity simultaneously, i.e. in the same physiological conditions. A frequently raised question at meeting and symposia is: "Do we really need a hybrid PET/MR system? Are there any advantages over acquiring sequential and separate PET and MR scans?" The present paper is an attempt to answer these questions specifically in relation to PET combined with functional magnetic resonance imaging (fMRI) and arterial spin labeling. EVIDENCE ACQUISITION: We searched (last update: June 2017) the databases PubMed, PMC, Google Scholar and Medline. We also included additional studies if they were cited in the selected articles. No language restriction was applied to the search, but the reviewed articles were all in English. Among all the retrieved articles, we selected only those performed using a hybrid PET/MR system. We found a total of 17 papers that were selected and discussed in three main groups according to the main radiopharmaceutical used: F-18-fluorodeoxyglucose (F-18-FDG) (N.=8), O-15-water (O-15-H2O) (N.=3) and neuroreceptors (N.=6). EVIDENCE SYNTHESIS: Concerning studies using F-18-FDG, simultaneous PET/fMRI revealed that global aspects of functional organization (e.g. graph properties of functional connections) are partially associated with energy consumption. There are remarkable spatial and functional similarities across modalities, but also discrepant findings. More work is needed on this point. There are only a handful of papers comparing blood flow measurements with PET O-15-H2O and MR arterial spin label (ASL) measures, and they show significant regional CBF differences between these two modalities. However, at least in one study the correlation at the level of gray, white matter, and whole brain is rather good (r=0.94, 0.8, 0.81 respectively). Finally, receptor studies show that simultaneous PET/fMRI could be a useful tool to characterize functional connectivity along with dynamic neuroreceptor adaptation in several physiological (e.g. working memory) or pathological (e. g. pain) conditions, with or without drug administrations. CONCLUSIONS: The simultaneous acquisition of PET (using a number of radiotracers) and functional MRI (using a number of sequences) offers exciting opportunities that we are just beginning to explore. The results thus far are promising in the evaluation of cerebral metabolism/flow, neuroreceptor adaptation, and network's energetic demand.
引用
收藏
页码:345 / 359
页数:15
相关论文
共 50 条
  • [21] Resting-State Networks as Simultaneously Measured with Functional MRI and PET
    Savio, Alexandre
    Fuenger, Sarah
    Tahmasian, Masoud
    Rachakonda, Srinivas
    Manoliu, Andrei
    Sorg, Christian
    Grimmer, Timo
    Calhoun, Vince
    Drzezga, Alexander
    Riedl, Valentin
    Yakushev, Igor
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (08) : 1314 - 1317
  • [22] PET Insert for PET/MR Brain Imaging
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (07) : 23N - 24N
  • [23] Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System
    Nakamoto, Ryusuke
    Nakamoto, Yuji
    Ishimori, Takayoshi
    Fushimi, Yasutaka
    Kido, Aki
    Togashi, Kaori
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (05) : 846 - 851
  • [24] MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration
    Schreibmann, Eduard
    Nye, Jonathon A.
    Schuster, David M.
    Martin, Diego R.
    Votaw, John
    Fox, Tim
    MEDICAL PHYSICS, 2010, 37 (05) : 2101 - 2109
  • [25] PET, MRI, and MRS for imaging of functional brain disorders
    Herholz, K
    Lanfermann, H
    CEREBRAL PROTECTION IN CEREBROVASCULAR AND AORTIC SURGERY, 1997, : 11 - 22
  • [26] Dedicated brain PET system of PET/MR for brain research
    Li Cheng
    Yaqiang Liu
    Tianyu Ma
    Shi Wang
    Qingyang Wei
    Tianpeng Xu
    EJNMMI Physics, 2 (Suppl 1)
  • [27] Cardiovascular Hybrid Imaging using PET/MRI
    Nensa, Felix
    Schlosser, Thomas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (12): : 1094 - 1101
  • [28] Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Thiessen, Jonathan D.
    Bishop, Daryl
    Stortz, Greg
    Kozlowski, Piotr
    Retiere, Fabrice
    Zhang, Xuezhu
    Sossi, Vesna
    SENSORS, 2014, 14 (08) : 14654 - 14671
  • [29] Self-gated Radial MRI for Respiratory Motion Compensation on Hybrid PET/MR Systems
    Grimm, Robert
    Fuerst, Sebastian
    Dregely, Isabel
    Forman, Christoph
    Hutter, Jana Maria
    Ziegler, Sibylle I.
    Nekolla, Stephan
    Kiefer, Berthold
    Schwaiger, Markus
    Hornegger, Joachim
    Block, Tobias
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 17 - 24
  • [30] Dopaminergic Modulation of Brain Functional Connectivity Using Simultaneous PET/Pharmacological MRI
    Tomasi, Dardo
    Manza, Peter
    Kojori, Ehsan Shokri
    Yonga, Michele-Vera
    Kroll, Danielle
    McPherson, Katherine
    Biesecker, Catherine
    dennis, EVan
    Johnson, Allison
    Zhang, Rui
    Yuan, Kai
    Kim, Sunny
    Butman, John
    Wang, Wen-Tung
    Wang, Gene-Jack
    Volkow, Nora
    NEUROPSYCHOPHARMACOLOGY, 2021, 46 (SUPPL 1) : 449 - 449