New strategy of substructure method to model long-span hybrid cable-stayed bridges under vehicle-induced vibration

被引:39
|
作者
Kong, X. [1 ]
Wu, D. J. [2 ]
Cai, C. S. [1 ]
Liu, Y. Q. [2 ]
机构
[1] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
[2] Tongji Univ, Dept Bridge Engn, Shanghai 200092, Peoples R China
关键词
Substructure method; Super-element; Mixed Dimensional Coupling (MDC) method; Component mode synthesis (CMS) method; Long-span hybrid cable-stayed bridge; Steel-concrete joint; Vehicle-bridge coupling analysis; DYNAMIC-RESPONSE;
D O I
10.1016/j.engstruct.2011.10.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hybrid cable-stayed bridges consist of steel and concrete bridge segments, of which steel-concrete joints are of great importance and raise strong research interest. Due to the limitation of the traditional methods, i.e., the member finite element (FE) method and Mixed Dimensional Coupling (MDC) method, the present study proposes a substructure method to model long span bridges. The current application of the substructure method is to extract some specific parts of the whole structure to refine and analyze them. Different from the routine substructure approach, here the entire structure is modeled in detail and divided into many substructures. All the substructures are then condensed into super-elements except the concerned part. The application of the method is then illustrated through numerical studies of the vehicle-bridge coupling vibration of the Jingyue Yangtze River Bridge with a main span of 816 m. The entire bridge is first divided into many substructures with a reasonable length. Among them, the concerned substructure with 23.8 m in length including the steel-concrete joint is modeled in detail but not formed into super-element, while all the other components are modeled in detail and formed into super-elements using the component mode synthesis (CMS) method. All the components including both the super-elements and non-super-elements are then assembled into a complete and fine full bridge model. Finally, the model is used for the vehicle-induced dynamic analysis under deterministic traffic flows. The results show that the joint works well, and the transition between the steel girders and concrete beams is very smooth. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:421 / 435
页数:15
相关论文
共 50 条
  • [21] Damage Identification in Long-Span Cable-Stayed Bridges Under Multiple Support Excitations
    Arezoo Bakhshizadeh
    Kabir Sadeghi
    Sina Ahmadi
    Javad Royaei
    International Journal of Civil Engineering, 2023, 21 : 1275 - 1290
  • [22] Nonlinear Coupled Vibration Behavior of BFRP Cables on Long-Span Cable-Stayed Bridges under Parametric Excitation
    Yang, Yaqiang
    Zhou, Zixian
    Guan, Yanlin
    Shi, Jianzhe
    Zhan, Qiwei
    Fahmy, Mohamed F. M.
    Wu, Bitao
    BUILDINGS, 2023, 13 (12)
  • [23] Temperature effects on modal frequencies of long-span cable-stayed bridges
    Sun, L.
    Zhou, Y.
    Xie, D.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 1091 - 1097
  • [24] Damping properties of FRP cables for long-span cable-stayed bridges
    Yaqiang Yang
    Xin Wang
    Zhishen Wu
    Changhai Peng
    Materials and Structures, 2016, 49 : 2701 - 2713
  • [25] Investigation of seismic performance of super long-span cable-stayed bridges
    Zhang, Xin-Jun
    Zhao, Chen-Yang
    Guo, Jian
    EARTHQUAKES AND STRUCTURES, 2018, 14 (06) : 493 - 503
  • [26] Aerostatic stability of long-span cable-stayed bridges: Parametric study
    Cheng, Jin
    Jiang, Jianjing
    Xiao, Rucheng
    Xiang, Haifan
    Tsinghua Science and Technology, 2003, 8 (02) : 201 - 205
  • [27] Integrated finite strip analysis for long-span cable-stayed bridges
    Naderian, Hamidreza
    Cheung, Moe M. S.
    Shen, Zhenyuan
    Dragomirescu, Elena
    COMPUTERS & STRUCTURES, 2015, 158 : 82 - 97
  • [28] Seismic Analysis of Long-Span Cable-Stayed Bridges by an Integrated Finite Strip Method
    Naderian, Hamidreza
    Cheung, Moe M. S.
    Shen, Zhenyuan
    Dragomirescu, Elena
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (03)
  • [29] Modal damping evaluation of hybrid FRP cable with smart dampers for long-span cable-stayed bridges
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2011, 93 (04) : 1231 - 1238
  • [30] Aerostatic Stability of Long-Span Cable-Stayed Bridges: Parametric Study
    程进
    江见鲸
    肖汝诚
    项海帆
    Tsinghua Science and Technology, 2003, (02) : 201 - 205