Experimental demonstration of the short bunch extraction by bunch rotation in a high-intensity rapid cycling proton synchrotron

被引:2
|
作者
Zhang, Linhao [1 ,2 ,3 ]
Chen, Yukai [1 ,3 ]
Tang, Jingyu [1 ,2 ,3 ]
Li, Xiao [1 ,3 ]
Liu, Yang [1 ,3 ]
Huang, Liangsheng [1 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Spallat Neutron Source Sci Ctr, Dongguan 523803, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1103/PhysRevAccelBeams.25.010401
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Short bunch proton beams are of great significance for the applications of white neutron beams and muon beams. The accelerator complex of the China Spallation Neutron Source (CSNS) was designed to support the applications mainly based on neutron scattering techniques where the proton pulse length is not very sensitive. Some theoretical and experimental studies have been performed to see if one can extract a short-bunch proton beam by bunch rotation from the rapid cycling synchrotron (RCS) at CSNS. The experimental results at RCS have evidently displayed the bunch lengthening and rotation process, which demonstrates the effectiveness of this method even with a very short available time for the rf gymnastic processes and a high-intensity beam. With a beam power of 50 kW and normal longitudinal emittance at the injection, the proton beam with a bunch length of about 53% with respect to the one in the normal operation mode was obtained and transported to the spallation target. With a reduced longitudinal emittance at injection and the beam power of 30 kW, the shortest extraction bunch length obtained is about 26% of the one in the normal operation mode. Different machine settings have also been tested to show the impact of the desynchronization between the rf and magnetic fields, the influence of the nonadiabatic rise time, and the adiabatic decay time of the rf voltage on the extraction bunch length. The experimental results are well consistent with the theoretical and simulated ones. It is interesting to observe that space charge has a beneficial effect on the bunch lengthening which will result in a shorter bunch at the extraction with the later bunch rotation. The controlled desynchronization method between the rf and magnetic fields in an RCS was also proven successful.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Focusing of short-pulse high-intensity laser-accelerated proton beams
    Teresa Bartal
    Mark E. Foord
    Claudio Bellei
    Michael H. Key
    Kirk A. Flippo
    Sandrine A. Gaillard
    Dustin T. Offermann
    Pravesh K. Patel
    Leonard C. Jarrott
    Drew P. Higginson
    Markus Roth
    Anke Otten
    Dominik Kraus
    Richard B. Stephens
    Harry S. McLean
    Emilio M. Giraldez
    Mingsheng S. Wei
    Donald C. Gautier
    Farhat N. Beg
    Nature Physics, 2012, 8 (2) : 139 - 142
  • [32] DESIGN AND PERFORMANCE OF A SMALL-ANGLE, HIGH-INTENSITY SECONDARY PARTICLE BEAM FROM THE CERN PROTON SYNCHROTRON
    BARBIER, M
    DOWELL, JD
    KALMUS, PIP
    LEONTIC, B
    LUNDBY, A
    MEUNIER, R
    PETRUCCI, G
    SOLINAS, L
    STROOT, JP
    SZEPTYCKA, M
    NUCLEAR INSTRUMENTS & METHODS, 1963, 20 (JAN): : 66 - 70
  • [33] An imaginary-γt lattice with dispersion-free straights for the 50 GeV high-intensity proton synchrotron
    Ng, KY
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 1000 - 1002
  • [34] Altitude Tents Do Not Impair Performance Response To Short-term High-intensity Cycling Training
    Martin, David T.
    Kinsman, Tahnee
    Eastwood, Annette
    Platt, Melanie
    Paton, Carl
    Hahn, Allan G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S294 - S294
  • [35] Effect of High-Intensity, Intermittent, Short-Duration Re-Warming Up on Cycling Sprint Performance
    Yamashita, Yuto
    Umemura, Yoshihisa
    JOURNAL OF HUMAN KINETICS, 2022, 83 (01) : 131 - 141
  • [36] EXTRACTION OF HIGH-INTENSITY ION BEAMS FROM PLASMA SOURCES: THEORETICAL AND EXPERIMENTAL TREATMENTS.
    Lejeune, Claude
    Advances in Electronics and Electron Physics, 1983, : 207 - 293
  • [38] The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer
    Tang, Zhuo-yue
    Zhao, Jian-nong
    Zhong, Wei-jia
    Luo, Yin-deng
    Wu, Wei
    Chen, Wei-juan
    Dai, Yu-bing
    TRANSLATIONAL ONCOLOGY, 2015, 8 (03): : 163 - 168
  • [39] Theoretical estimation and experimental design of high-intensity far-infrared to MM-wave coherent synchrotron radiation generated by short electron bunches at BFEL
    Junbiao, Zhu
    Yonggui, Li
    Jialin, Xie
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000, 447 (03) : 587 - 592
  • [40] Theoretical estimation and experimental design of high-intensity far-infrared to MM-wave coherent synchrotron radiation generated by short electron bunches at BFEL
    Zhu, JB
    Li, YG
    Xie, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 447 (03): : 587 - 592