Monitoring of dissolved reactive phosphorus in wastewaters by flow injection analysis .2. On-line monitoring system

被引:6
|
作者
Benson, RL
Truong, YB
McKelvie, ID
Hart, BT
Bryant, GW
Hilkmann, WP
机构
[1] MONASH UNIV,WATER STUDIES CTR,CAULFIELD,VIC 3145,AUSTRALIA
[2] MONASH UNIV,DEPT CHEM,CAULFIELD,VIC 3145,AUSTRALIA
[3] BHP RES,NEWCASTLE LABS,WALLSEND,NSW 2287,AUSTRALIA
关键词
flow injection; phosphorus; wastewaters; on-line monitoring; filtration;
D O I
10.1016/0043-1354(96)00009-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An automated-flow injection (FI) analyser for the determination of dissolved reactive phosphorus (DRP) in wastewaters is described. The analytical method is based on the formation of molybdenum blue. The limits of detection using a solid-state photometric detector (LED-photodiode) were 0.05 mg P 1(-1) and the linear range was 0-20 mg P 1(-1). Details of construction, field-testing (including sample filtration) and validation are given. The analyser proved very reliable during an unattended operational period of seven days. Operational costs were minimised, with low reagent consumption and minimal operator intervention. Data retrieval and analyser status were remotely interrogated by means of a cellular telephone-based communications link. The real-time results from the analyser showed good correlation with those generated by a validated laboratory method. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:1965 / 1971
页数:7
相关论文
共 50 条
  • [41] Development of a mass-producible glucose biosensor and flow-injection analysis system suitable for on-line monitoring during fermentations
    White, SF
    Tothill, IE
    Newman, JD
    Turner, APF
    ANALYTICA CHIMICA ACTA, 1996, 321 (2-3) : 165 - 172
  • [42] A flow injection analysis system for on-line monitoring of cutinase activity at outlet of an expanded bed adsorption column almost in real time
    Almeida, Claudio F.
    Calado, Cecilia R. C.
    Bernardino, Susana A.
    Cabral, Joaquim M. S.
    Fonseca, Luis P.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2006, 81 (10) : 1678 - 1684
  • [43] On-line simultaneous monitoring of ammonia and glutamine in a hollow-fiber reactor using flow injection analysis
    Stoll, TS
    Ruffieux, PA
    Schneider, M
    vonStockar, U
    Marison, IW
    JOURNAL OF BIOTECHNOLOGY, 1996, 51 (01) : 27 - 35
  • [44] Flow injection analysis-based methodology for automatic on-line monitoring and quality control for biodiesel production
    Pinzi, S.
    Priego Capote, F.
    Ruiz Jimenez, J.
    Dorado, M. P.
    Luque de Castro, M. D.
    BIORESOURCE TECHNOLOGY, 2009, 100 (01) : 421 - 427
  • [45] On-line simultaneous monitoring of ammonia and glutamine in a hollow-fiber reactor using flow injection analysis
    Institute of Chemical Engineering, Swiss Fed. Inst. of Technol. , CH-1015 Lausanne, Switzerland
    不详
    不详
    J. BIOTECHNOL., 1 (27-35):
  • [46] On-line monitoring of glucose in mammalian cell culture using a flow injection analysis (FIA) mediated biosensor
    Male, KB
    Gartu, PO
    Kamen, AA
    Luong, JHT
    BIOTECHNOLOGY AND BIOENGINEERING, 1997, 55 (03) : 497 - 504
  • [47] A flow injection-ETAAS system for the on-line determination of total and dissolved silica in waters
    Burguera, M
    Burguera, JL
    Carrero, P
    Rondón, C
    TALANTA, 2002, 58 (06) : 1157 - 1166
  • [48] Reliability of on-line corrosion monitoring system
    Xiang, Min
    Li, Chang-Jun
    Liao, Ke-Xi
    Yang, Yi
    Xinan Shiyou Daxue Xuebao/Journal of Southwest Petroleum University, 2007, 29 (03): : 157 - 159
  • [49] An On-line Monitoring System for Navigation Equipment
    Wang, Bo
    Yang, Ping
    Liu, Jing
    Yang, Zhengbo
    Liang, Fei
    2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, RESOURCE AND ENVIRONMENTAL ENGINEERING (MSREE 2017), 2017, 1890
  • [50] On-line energy monitoring in a control system
    Blevins, T
    Yang, M
    ISA 2002 TECHNOLOGY UPDATE, VOL LVII, PT 2, 2002, 423 : 57 - 65