Monitoring of dissolved reactive phosphorus in wastewaters by flow injection analysis .2. On-line monitoring system

被引:6
|
作者
Benson, RL
Truong, YB
McKelvie, ID
Hart, BT
Bryant, GW
Hilkmann, WP
机构
[1] MONASH UNIV,WATER STUDIES CTR,CAULFIELD,VIC 3145,AUSTRALIA
[2] MONASH UNIV,DEPT CHEM,CAULFIELD,VIC 3145,AUSTRALIA
[3] BHP RES,NEWCASTLE LABS,WALLSEND,NSW 2287,AUSTRALIA
关键词
flow injection; phosphorus; wastewaters; on-line monitoring; filtration;
D O I
10.1016/0043-1354(96)00009-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An automated-flow injection (FI) analyser for the determination of dissolved reactive phosphorus (DRP) in wastewaters is described. The analytical method is based on the formation of molybdenum blue. The limits of detection using a solid-state photometric detector (LED-photodiode) were 0.05 mg P 1(-1) and the linear range was 0-20 mg P 1(-1). Details of construction, field-testing (including sample filtration) and validation are given. The analyser proved very reliable during an unattended operational period of seven days. Operational costs were minimised, with low reagent consumption and minimal operator intervention. Data retrieval and analyser status were remotely interrogated by means of a cellular telephone-based communications link. The real-time results from the analyser showed good correlation with those generated by a validated laboratory method. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:1965 / 1971
页数:7
相关论文
共 50 条
  • [1] Monitoring of dissolved reactive phosphorus in wastewaters by flow injection analysis .1. Method development and validation
    Benson, RL
    Truong, YB
    McKelvie, ID
    Hart, BT
    WATER RESEARCH, 1996, 30 (09) : 1959 - 1964
  • [2] Sequential Injection Analysis-Based System for On-Line Monitoring of Nitrite and Nitrate in Wastewaters
    Rui A. S. Lapa
    José L. F. C. Lima
    Ivone V. O. S. Pinto
    Analytical Sciences, 2000, 16 : 1157 - 1160
  • [3] Sequential injection analysis-based system for on-line monitoring of nitrite and nitrate in wastewaters
    Lapa, RAS
    Lima, JLFC
    Pinto, IVOS
    ANALYTICAL SCIENCES, 2000, 16 (11) : 1157 - 1160
  • [4] Fast on-line flow injection analysis system for IgG monitoring in bioprocesses
    Reinecke, M
    Scheper, T
    JOURNAL OF BIOTECHNOLOGY, 1997, 59 (1-2) : 145 - 153
  • [5] A flow injection flow cytometry system for on-line monitoring of bioreactors
    Zhao, Rui
    Natarajan, Arvind
    Srienc, Friedrich
    Biotechnology and Bioengineering, 62 (05): : 609 - 617
  • [6] A flow injection flow cytometry system for on-line monitoring of bioreactors
    Zhao, R
    Natarajan, A
    Srienc, F
    BIOTECHNOLOGY AND BIOENGINEERING, 1999, 62 (05) : 609 - 617
  • [7] On-line monitoring of galactoside conjugates and glycerol by flow injection analysis
    Vega, FA
    Núñez, CG
    Weigel, B
    Hitzmann, B
    Ricci, JCD
    ANALYTICA CHIMICA ACTA, 1998, 373 (01) : 57 - 62
  • [8] The application analysis of the on-line monitoring system of dissolved gas in transformer oil
    Li Yanming
    Liu Gang
    Liang Ying
    Xing Yan
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 747 - +
  • [9] Flow injection system for on-line monitoring of fumaric acid in biological processes
    Rhee, JI
    Sohn, OJ
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 71 - 80
  • [10] On-line dyebath monitoring by sequential injection analysis
    Draper, Sara L.
    Beck, Keith R.
    Smith, Brent
    AATCC Magazine, 2001, 1 (01): : 24 - 28