Active micro-structured arrays for X-ray optics

被引:8
|
作者
Michette, Alan [1 ]
Button, Tim [2 ]
Dunare, Camelia [3 ]
Feldman, Charlotte [4 ]
Folkard, Melvyn [5 ]
Hart, David [5 ]
McFaul, Chris [1 ]
Morrison, Graeme R. [1 ]
Parkes, William [3 ]
Pfauntsch, Slawka [1 ]
Powell, A. Keith [1 ]
Rodriguez-Sanmartin, Daniel [2 ]
Sahraei, Shahin [1 ]
Stevenson, Tom [3 ]
Vojnovic, Boris [5 ]
Willingaled, Richard [4 ]
Zhangb, Dou [2 ]
机构
[1] Kings Coll London, Dept Phys, Strand, London WC2R 2LS, England
[2] Univ Birmingham, Dept Met & Mat, Birmingham B15 2TT, W Midlands, England
[3] Univ Edinburgh, Scottish Microelect Ctr, Edinburgh EH9 3JF, Midlothian, Scotland
[4] Univ Leicester, Dept Phys & Astron, Leicester LE1 7RH, Leics, England
[5] Mt Vernon Hosp, Gray Canc Inst, Northwood HA6 2JR, Middx, England
关键词
X-ray reflection; grazing incidence; active/adaptive reflectors;
D O I
10.1117/12.735500
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The UK Smart X-Ray Optics programme is developing the techniques required to both enhance the performance of existing X-ray systems, such as X-ray telescopes, while also extending the utility of X-ray optics to a broader class of scientific investigation. The approach requires the control of the inherent aberrations of X-ray systems using an active/adaptive method. One of the technologies proposed to achieve this is micro-structured optical arrays, which use grazing incidence reflection through consecutive aligned arrays of channels. Although such arrays are similar in concept to polycapillary and microchannel plate optics, they are more flexible. Bending the arrays allows variable focal length, while flexing parts of them provides adaptive or active systems. Custom configurations can be designed, using ray tracing and finite element analysis, for applications from sub-keV to several-keV X-rays. The channels may be made using deep silicon etching, which can provide appropriate aspect ratios, and flexed using piezo actuators. An exemplar application will be in the micro-probing of biological cells and tissue samples using Ti K-alpha radiation (4.5 keV) in studies related to radiation induced cancers.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Silicon micro-pore X-ray optics
    Ezoe, Y.
    Koshiishi, M.
    Mita, M.
    Mitsuda, K.
    Hoshino, A.
    Ishisaki, Y.
    Takano, T.
    Maeda, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 817 - 820
  • [22] Active microstructured x-ray optical arrays
    Michette, Alan G.
    Pfauntsch, Slawka J.
    Sahraei, Shahin
    Shand, Matthew
    Morrison, Graeme R.
    Hart, David
    Vojnovic, Boris
    Stevenson, Tom
    Parkes, William
    Dunare, Camelia
    Willingale, Richard
    Feldman, Charlotte H.
    Button, Tim W.
    Zhang, Dou
    Rodriguez-Sanmartin, Daniel
    Wang, Hongchang
    Smith, Andy D.
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE, 2009, 7360
  • [23] 3D micro-structured arrays of ZnΟ nanorods
    Argyro N. Giakoumaki
    George Kenanakis
    Argyro Klini
    Maria Androulidaki
    Zacharias Viskadourakis
    Maria Farsari
    Alexandros Selimis
    Scientific Reports, 7
  • [24] Capacity Gain of MIMO Systems with Micro-structured Antenna Arrays
    Gaffet, Nadine Malhouroux
    Pajusco, Patrice
    Burghelea, Roxana
    Leray, Christian
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 2551 - 2555
  • [25] Excitation dynamics of micro-structured atmospheric pressure plasma arrays
    Boettner, H.
    Waskoenig, J.
    O'Connell, D.
    Kim, T. L.
    Tchertchian, P. A.
    Winter, J.
    Schulz-von der Gathen, V.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (12)
  • [26] Micro-pore X-ray optics developments and application to an X-ray timing mission
    Beijersbergen, M
    Bavdaz, M
    Buis, EJ
    Lumb, D
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 468 - 474
  • [27] Micro Energy Dispersive X-Ray Diffraction Analysis by Polycapillary X-Ray Optics Focusing
    Duan Zeming
    Jiang Qili
    Liu Jun
    Pan Qiuli
    Cheng Lin
    ACTA OPTICA SINICA, 2018, 38 (12)
  • [28] Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis
    Komatani, Shintaro
    Nakamachi, Kazuo
    Nakano, Kazuhiko
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Bando, Atsushi
    Tsuji, Kouichi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 260 - 263
  • [29] Determination of X-ray excitation spectra in micro X-ray fluorescence spectrometry with capillary optics
    Perez, R. D.
    Sosa, C.
    Sbarato, V.
    Leani, J.
    Sanchez, H. J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 117 : 23 - 28
  • [30] 3D micro-structured arrays of ZnO nanorods
    Giakoumaki, Argyro N.
    Kenanakis, George
    Klini, Argyro
    Androulidaki, Maria
    Viskadourakis, Zacharias
    Farsari, Maria
    Selimis, Alexandros
    SCIENTIFIC REPORTS, 2017, 7