Polymerization Shrinkage and Depth of Cure of Bulk-Fill Resin Composites and Highly Filled Flowable Resin

被引:134
|
作者
Jang, J-H [1 ]
Park, S-H [2 ]
Hwang, I-N [3 ]
机构
[1] Kyung Hee Univ Hosp Gangdong, Dept Conservat Dent, Seoul, South Korea
[2] Yonsei Univ, Oral Sci Res Ctr, Conservat Dent, Seoul 120749, South Korea
[3] Chonnam Natl Univ, Coll Dent, Dept Conservat Dent, Gwang Ju, South Korea
关键词
MECHANICAL-PROPERTIES; STRESS; MICROHARDNESS;
D O I
10.2341/13-307-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the polymerization behavior and depth of cure (DOC) of recently introduced resin composites for posterior use: highly filled flowable composite and composites for bulk fill. A highly filled flowable (G-aenial Universal Flo [GUF]), two bulk-fill flowables (Surefil SDR Flow [SDR] and Venus Bulk fill [VBF]), and a bulk-fill nonflowable composite (Tetric N-Ceram Bulk fill [TBF]) were compared with two conventional composites (Tetric Flow [TF], Filtek Supreme Ultra [FS]). Linear polymerization shrinkage and polymerization shrinkage stress were each measured with custom-made devices. To evaluate DOC, the composite specimen was prepared using a mold with a hole of 4 mm depth and 4 mm internal diameter. The hole was bulk filled with each of the six composites and light cured for 20 seconds, followed by 24 hours of water storage. The surface hardness was measured on the top and the bottom using a Vickers microhardness (HV) indenter. The linear polymerization shrinkage of the composite specimens after photo-initiation decreased in the following order: TF and GUF. VBF. SDR. FS and TBF (p<0.05). The polymerization shrinkage stress of the six composite groups decreased in the following order: GUF > TF and VBF > SDR > FS and TBF (p<0.05). The mean bottom surface HV of SDR and VBF exceeded 80% of the top surface HV (HV-80%). However, the bottom of GUF and TBF failed to reach HV-80%. A highly filled flowable (GUF) revealed limitations in polymerization shrinkage and DOC. Bulk-fill flowables (SDR and VBF) were properly cured in 4-mm bulk, but they shrank more than the conventional nonflowable composite. A bulk-fill nonflowable (TBF) showed comparable shrinkage to the conventional nonflowable composite, but it was not sufficiently cured in the 4-mm bulk.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 50 条
  • [21] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [23] Depth of cure of bulk fill resin composites: A systematic review
    Wanderley Lima, Renally Bezerra
    Madrid Troconis, Cristhian Camilo
    Pereira Moreno, Marina Barreto
    Murillo-Gomez, Fabian
    De Goes, Mario Fernando
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2018, 30 (06) : 492 - 501
  • [24] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Dalia Kaisarly
    D. Meierhofer
    M. El Gezawi
    P. Rösch
    K.H. Kunzelmann
    Clinical Oral Investigations, 2021, 25 : 4927 - 4940
  • [25] Effects of flowable liners on the shrinkage vectors of bulk-fill composites
    Kaisarly, Dalia
    Meierhofer, D.
    El Gezawi, M.
    Roesch, P.
    Kunzelmann, K. H.
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (08) : 4927 - 4940
  • [26] Comparison of microleakage between bulk-fill flowable and nanofilled resin-based composites
    Alsagob, Eman I.
    Bardwell, David N.
    Ali, Ala O.
    Khayat, Samer G.
    Stark, Paul C.
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2018, 10 (02): : 102 - 109
  • [27] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [28] Effect of high irradiance and short exposure times on the depth of cure of six bulk-fill resin composites
    dos Santos, Daniela Bandeira
    Romano, Beatriz de Cassia
    Pecorari, Vanessa Gallego Arias
    Price, Richard Bengt
    Giannini, Marcelo
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2024, 132 (04)
  • [29] Comparison of polymerization shrinkage of a new bulk-fill flowable composite with other composites: An in vitro study
    Tusi, Somayeh Khoramian
    Hamdollahpoor, Hajar
    Savadroodbari, Maryam Mohammadi
    Fathollahi, Mahmood Sheikh
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2022, 8 (06): : 1605 - 1613
  • [30] Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites
    Marigo, L.
    Spagnuolo, G.
    Malara, F.
    Martorana, G. E.
    Cordaro, M.
    Lupi, A.
    Nocca, G.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2015, 19 (23) : 4469 - 4480