Gamma spectrometric monitoring of environmental radioactivity using a mobile equipment

被引:3
|
作者
Aarnio, PA [1 ]
Ala-Heikkila, JJ [1 ]
Hakulinen, TT [1 ]
Nikkinen, MT [1 ]
机构
[1] Helsinki Univ Technol, Dept Engn Math & Phys, FIN-02015 HUT, Finland
关键词
D O I
10.1007/BF02389675
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using gamma-spectrometry systems on mobile units with accurate position information is a convenient means for surveying large areas for radioactive fallout or finding hot spots due to misplaced sources or releases from nuclear installations. Traditionally, large (tens of litres) high efficiency NaI(TI) detectors have been used for the purpose. HPGe detectors, however, offer certain advantages which can often compensate for their lower efficiency. This kind of remote sensing, regardless of detector type, requires specialized software. In order to provide accurate position information, the integration times must be kept as short as possible. This is especially true for fast air-borne measurements where counting periods below one second are desirable. We have constructed a special version of SAMPO software which controls data acquisition and runs real-time gamma-spectrum analysis including peak determination, nuclide identification, activity calculations, and reporting. The measurement/analysis cycle can be reduced down to 0.5 seconds on a standard Pentium-based PC. The analysis results are combined with accurate co-ordinates from a differential GPS system on a color coded map. The system is also able to give alarms based on different criteria. We have already measured and analyzed more than 500 000 spectra in field applications using jets, helicopters, cars, and also on-foot.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 50 条
  • [31] A comparison of determination methods for uranium radioactivity in environmental soil samples using a gamma spectrometer
    Maeng, Seongjin
    Lee, HaeYoung
    Park, Seong Jin
    Lee, Sang Hoon
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (07) : 2929 - 2938
  • [32] A METHOD OF REDUCING THE DISTURBING EFFECTS IN GAMMA-SPECTROMETRIC MEASUREMENTS OF ROCK RADIOACTIVITY
    KRESL, M
    VANKOVA, V
    STUDIA GEOPHYSICA ET GEODAETICA, 1982, 26 (01) : 66 - 73
  • [33] A comparison of determination methods for uranium radioactivity in environmental soil samples using a gamma spectrometer
    Seongjin Maeng
    HaeYoung Lee
    Seong Jin Park
    Sang Hoon Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 2929 - 2938
  • [34] Set up of a gamma spectrometry mobile unit equipped with LaBr3(Ce) detectors for radioactivity monitoring
    Prieto, E.
    Jabaloyas, E.
    Casanovas, R.
    Rovira, C.
    Salvado, M.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168 (168)
  • [35] Optimisation of spectrometric gamma-gamma probe configuration using very low radioactivity sources for lead and zinc grade determination in borehole logging
    Asfahani, J
    APPLIED RADIATION AND ISOTOPES, 1999, 51 (04) : 449 - 459
  • [36] FUEL TANK ENVIRONMENTAL MONITORING EQUIPMENT
    BIRCH, S
    AEROSPACE ENGINEERING, 1994, 14 (1-2) : 15 - 15
  • [37] Radioactivity monitoring in environmental water and air around QNPP
    XIANG Yuanyi WANG Kan ZHANG Yu CAO Zhonggang YE Jida WANG Hongfeng (Zhejiang Province Environmental Radiation Monitoring Center
    Nuclear Science and Techniques, 2007, (05) : 316 - 320
  • [38] Quality assurance and quality control in environmental radioactivity monitoring
    Nikolic, J. D. Krneta
    Todorovic, D. J.
    Jankovic, M. M.
    Pantelic, G. K.
    Rajacic, M. M.
    QUALITY ASSURANCE AND SAFETY OF CROPS & FOODS, 2014, 6 (04) : 403 - 409
  • [39] A low-cost instrumentation for monitoring of the environmental radioactivity
    Tataroglu, Gokcen
    Ozben, Cenap S.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [40] Gamma-ray spectrometric equipment for detecting nuclear materials.
    Ulin, SE
    Chernysheva, IV
    Dmitrenko, VV
    Gratchev, VM
    Kondakova, ON
    Krivova, KV
    Smirnov, SA
    Sokolov, DV
    Uteshev, ZM
    Vlasik, KF
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 271 - 278