Bone Recontouring in Fresh Sockets with Buccal Bone Loss: A Cone Beam Computed Tomography Study

被引:15
|
作者
Crespi, Roberto [1 ]
Cappare, Paolo [1 ]
Gherlone, Enrico F. [1 ]
机构
[1] Univ Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, Milan, Italy
关键词
buccal bone recontouring; cone beam computed tomography; fresh socket; HUMAN EXTRACTION SOCKETS; SINGLE-TOOTH EXTRACTION; REGENERATION; RIDGE; IMMEDIATE; SITES; TEETH;
D O I
10.11607/jomi.3506
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to assess buccal bone plate recontouring in maxillary fresh extraction sockets with buccal bone loss using cone beam computed tomography (CBCT). Materials and Methods: Healthy patients who required the extraction of one tooth with buccal bone loss in the maxilla were included in this study. CBCT examinations were made before extractions and after 3 months. The alveolar bone levels were assessed from the most coronal, buccal, and palatal bone in which the crest was identified. Buccolingual width at the apical and coronal level was also measured. Results: Fifty healthy patients underwent 50 extractions. Mean bone levels for both single-rooted and multiple-rooted teeth, from a buccopalatal perspective, showed no statistically significant difference between preextraction status and 3 months later. However, in both groups, mean bone levels of the buccal bone plate showed statistically significant differences between extraction and 3 months later. In single-rooted teeth, a mean bone gain of 5.36 +/- 2.65 mm was seen after 3 months, and for multiple-rooted teeth, a mean bone gain of 5.89 +/- 2.88 mm was seen. Growth in buccolingual width was seen; nevertheless, volume dimensional changes were reported after tooth extraction. Conclusions: In the first months after extraction, it is possible to observe the formation of buccal bone in sockets with previous buccal bone loss.
引用
收藏
页码:863 / 868
页数:6
相关论文
共 50 条
  • [41] Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images
    Wood, Ryan
    Sun, Zongyang
    Chaudhry, Jahanzeb
    Tee, Boon Ching
    Kim, Do-Gyoon
    Leblebicioglu, Binnaz
    England, Greg
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (03) : 353 - 363
  • [42] Accuracy of Presurgical Limited Field of View Cone-beam Computed Tomography in Predicting Intraoperative Buccal Cortical Bone
    Mayo, Chester V., Jr.
    Replogle, Karan J.
    Marshall, J. Gordon
    Best, Al M.
    Sehgal, Harjit Singh
    Melo, Saulo L. Sousa
    Sedgley, Christine M.
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 169 - 177
  • [43] Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
    Slagter, Kirsten W.
    Raghoebar, Gerry M.
    Vissink, Arjan
    Meijer, Henny J. A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2015, 1 (01):
  • [44] Cone Beam Computed Tomography Assessment of the Buccal Bone Thickness in Anterior Maxillary Teeth: Relevance to Immediate Implant Placement
    Gakonyo, Joseph
    Mohamedali, Adnaan Jabir
    Mungure, Edward Kabubei
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 880 - 887
  • [45] Factors affecting the possibility to detect buccal bone condition around dental implants using cone beam computed tomography
    Liedke, Gabriela S.
    Spin-Neto, Rubens
    da Silveira, Heloisa E. D.
    Schropp, Lars
    Stavropoulos, Andreas
    Wenzel, Ann
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1082 - 1088
  • [46] Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
    Kirsten W Slagter
    Gerry M Raghoebar
    Arjan Vissink
    Henny J A Meijer
    International Journal of Implant Dentistry, 1 (1)
  • [47] Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging
    Draenert, F. G.
    Gebhart, F.
    Berthold, M.
    Gosau, M.
    Wagner, W.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (05) : 264 - 269
  • [48] Effect of the buccal gap width following immediate implant placement on the buccal bone wall: A retrospective cone-beam computed tomography analysis
    Levine, Robert A.
    Dias, Debora R.
    Wang, Ping
    Araujo, Mauricio G.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (04) : 403 - 413
  • [49] Morphologic examination of the temporal bone by cone beam computed tomography: Comparison with multislice helical computed tomography
    Dahmani-Causse, M.
    Marx, M.
    Deguine, O.
    Fraysse, B.
    Lepage, B.
    Escude, B.
    EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2011, 128 (05) : 230 - 235
  • [50] Buccal bone thickness at dental implants in the aesthetic zone: A 1-year follow-up cone beam computed tomography study
    Slagter, Kirsten W.
    Raghoebar, Gerry M.
    Bakker, Nicolaas A.
    Vissink, Arjan
    Meijer, Henny J. A.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (01) : 13 - 19