Miniaturization of holographic Fourier-transform spectrometers

被引:6
|
作者
Agladze, NI [1 ]
Sievers, AJ [1 ]
机构
[1] Cornell Univ, Atom & Solid State Phys Lab, Ithaca, NY 14853 USA
关键词
D O I
10.1364/AO.43.006568
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Wave propagation equations in the stationary-phase approximation have been used to identify the theoretical bounds of a miniature holographic Fourier-transform spectrometer (HFTS). It is demonstrated that the HFTS throughput can be larger than for a scanning Fourier-transform spectrometer. Given room- or a higher-temperature constraint, a small HFTS has the potential to outperform a small multichannel dispersive spectrograph with the same resolving power because of the size dependence of the signal-to-noise ratio. These predictions are used to analyze the performance of a miniature HFTS made from simple optical components covering a broad spectral range from the LTV to the near IR. The importance of specific primary aberrations in limiting the HFTS performance has been both identified and verified. (C) 2004 Optical Society of America.
引用
收藏
页码:6568 / 6579
页数:12
相关论文
共 50 条
  • [31] SIGNAL-TO-NOISE CHARACTERISTICS OF PHOTODIODE ARRAY FOURIER-TRANSFORM SPECTROMETERS
    VANTASSEL, RA
    WONG, WK
    MIKROCHIMICA ACTA, 1988, 2 (1-6) : 323 - 324
  • [32] AMBIENT-TEMPERATURE ABSOLUTE RADIOMETRY USING FOURIER-TRANSFORM SPECTROMETERS
    LAPORTE, DD
    HOWITT, R
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 364 : 2 - 7
  • [33] POSTDISPERSION SYSTEM FOR ASTRONOMICAL OBSERVATIONS WITH FOURIER-TRANSFORM SPECTROMETERS IN THE THERMAL INFRARED
    WIEDEMANN, G
    JENNINGS, DE
    HANEL, RH
    KUNDE, VG
    MOSELEY, SH
    LAMB, G
    PETROFF, MD
    STAPELBROEK, MG
    APPLIED OPTICS, 1989, 28 (01): : 139 - 145
  • [34] Temperature dependence mitigation in stationary Fourier-transform on-chip spectrometers
    Herrero-Bermello, Alaine
    Velasco, Aitor V.
    Podmore, Hugh
    Cheben, Pavel
    Schmid, Jens H.
    Janz, Siegfried
    Calvo, Maria L.
    Xu, Dan-Xia
    Scott, Alan
    Corredera, Pedro
    OPTICS LETTERS, 2017, 42 (11) : 2239 - 2242
  • [35] Effect of apodization on the retrieval of geophysical parameters from Fourier-transform spectrometers
    Amato, U
    De Canditiis, D
    Serio, C
    APPLIED OPTICS, 1998, 37 (27): : 6537 - 6543
  • [36] WAVENUMBER SCALE SHIFT IN FOURIER-TRANSFORM INFRARED SPECTROMETERS DUE TO VIGNETTING
    HIRSCHFELD, T
    APPLIED SPECTROSCOPY, 1976, 30 (05) : 549 - 550
  • [37] A REVIEW OF SPACEBORNE INFRARED FOURIER-TRANSFORM SPECTROMETERS FOR REMOTE-SENSING
    PERSKY, MJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (10): : 4763 - 4797
  • [38] SAMPLING JITTER IN FOURIER-TRANSFORM SPECTROMETERS - SPECTRAL BROADENING AND NOISE EFFECTS
    MEYNART, R
    APPLIED OPTICS, 1992, 31 (30): : 6383 - 6388
  • [39] Temperature drift compensation in Fourier-transform integrated micro-spectrometers
    Velasco, A. V.
    Galindo-Santos, J.
    Cheben, P.
    Calvo, M. L.
    Schmid, J.
    Delage, A.
    Xu, Dan-Xia
    Janz, S.
    Corredera, P.
    OPTICA PURA Y APLICADA, 2015, 48 (04): : 283 - 289
  • [40] Fourier-transform spectral measurement with waveguide holographic-grating
    Hu, ML
    Liu, JF
    Li, YL
    Tan, YS
    FIBER OPTICS AND OPTOELECTRONICS FOR NETWORK APPLICATIONS, 2001, 4603 : 196 - 200