Determination of D-lactate content in poly(lactic acid) using polarimetry

被引:31
|
作者
Feng, Li-Dong [1 ,2 ]
Sun, Bin [1 ,2 ]
Bian, Xin-Chao [1 ,2 ]
Chen, Zhi-Ming [2 ]
Chen, Xue-Si [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Changchun 130022, Peoples R China
[2] Zhejiang Hisun Biomat Co Ltd, Taizhou 31800, Zhejiang, Peoples R China
关键词
Poly (lactic acid); D-lactate unit; Lactide; Specific rotation; Error; Influencing factor; RING-OPENING POLYMERIZATION; MOLECULAR-WEIGHT; H-1-NMR; POLYLACTIDES; C-13;
D O I
10.1016/j.polymertesting.2010.06.005
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A method has been developed to quantitatively determine the is-lactate content in poly (lactic acid) (PLA) using polarimetry. Various factors influencing test results, including monomer and other additives in samples, and temperature, have been considered in more detail. When the monomer content is 1.0% (w/w), the negative error is not more than 0.41%. For some additives without optical activity that are soluble in the solvent for PLA, when their content is 1.0%, the positive error produced is less than 0.50%. However, other additives that cannot be dissolved in the PLA solvent, such as inorganic components, can cause the indicator of the polarimeter to fluctuate considerably, leading to variation in test results. The absolute error caused by variation in temperature is not more than 0.1% and can be ignored at room temperature of from 15 to 35 C. A precipitation method can be used to separate and remove interfering components from PLA. When all of the interferents have no optical activity, are soluble in a solvent for PLA and their content is known, the D-lactate content can be directly measured by polarimetry. This method is applicable to the determination of D-lactate content in PLA, including copolymers of L- and D-lactic acid, and blends of poly (L-lactic acid) and poly (D-lactic acid). The test results are consistent with those obtained by HPLC, as indicated by the residual standard deviation of the two methods: (delta) over bar = 0.56%. The relative standard deviation (RSD) of the measurements is 3.7%, indicating that this method is suitably precise. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:771 / 776
页数:6
相关论文
共 50 条
  • [41] NADH ELECTROCHEMICAL SENSOR FOR THE ENZYMATIC DETERMINATION OF L-LACTATE AND D-LACTATE AND 3-HYDROXYBUTYRATE USING A FLOW-INJECTION ANALYSIS
    MARRAZZA, G
    CAGNINI, A
    MASCINI, M
    ELECTROANALYSIS, 1994, 6 (03) : 221 - 226
  • [42] Determination of lactic acid and poly(lactic acid)s in a dermatological formulation by capillary electrophoresis
    Sharman, DC
    ANALYST, 1997, 122 (07) : 709 - 713
  • [43] Simultaneous determination of L- and D-lactate by enzyme modified carbon paste electrodes
    Narasaiah, D
    Spohn, U
    Gorton, L
    ANALYTICAL LETTERS, 1996, 29 (02) : 181 - 201
  • [44] Characteristics of D-lactate Dehydrogenase from the High Potential D-lactic Acid Producer Leuconostoc pseudomesenteroides TC49 Isolated from Thailand
    Chemama, Tasneem
    Hayashi, Junji
    Wakayama, Mamoru
    Thongwai, Narumol
    CHIANG MAI JOURNAL OF SCIENCE, 2021, 48 (01): : 42 - 55
  • [46] Lipase-catalyzed enantioselective synthesis of (R,R)-lactide from alkyl lactate to produce PDLA (poly D-lactic acid) and stereocomplex PLA (poly lactic acid)
    Jeon, Byoung Wook
    Lee, Jumin
    Kim, Hyun Sook
    Cho, Dae Haeng
    Lee, Hyuk
    Chang, Rakwoo
    Kim, Yong Hwan
    JOURNAL OF BIOTECHNOLOGY, 2013, 168 (02) : 201 - 207
  • [47] Lipase-catalyzed enantioselective synthesis of R-lactide from alkyl lactate to produce PDLA (poly D-lactic acid) and stereocomplex PLA (poly lactic acid)
    Jeon, Byoung Wook
    Lee, Jumin
    Le, Anh Tuan Quang
    Lee, Seorim
    Cho, Dae Haeng
    Lee, Hyeok
    Chang, Rakwoo
    Kim, Yong Hwan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [48] Hydrolysis of poly(lactic acid) into calcium lactate using ionic liquid [Bmim][OAc] for chemical recycling
    Song, Xiuyan
    Wang, Hui
    Yang, Xuequn
    Liu, Fusheng
    Yu, Shitao
    Liu, Shiwei
    POLYMER DEGRADATION AND STABILITY, 2014, 110 : 65 - 70
  • [49] Hydrolysis of poly(lactic acid) into calcium lactate using ionic liquid [Bmim][OAc] for chemical recycling
    Song, Xiuyan
    Wang, Hui
    Yang, Xuequn
    Liu, Fusheng
    Yu, Shitao
    Liu, Shiwei
    Polymer Degradation and Stability, 2014, 110 (01) : 65 - 70
  • [50] Hydrolysis of poly(lactic acid) into calcium lactate using ionic liquid [Bmim][OAc] for chemical recycling
    Song, Xiuyan
    Wang, Hui
    Yang, Xuequn
    Liu, Fusheng
    Yu, Shitao
    Liu, Shiwei
    Polymer Degradation and Stability, 2014, 110 : 65 - 70