Label-free dynamic light scattering assay for C-reactive protein detection using magnetic nanoparticles

被引:7
|
作者
Antonio, Maria [1 ]
Lima, Tania [2 ,3 ,4 ]
Vitorino, Rui [2 ,5 ,6 ]
Daniel-da-Silva, Ana L. [1 ]
机构
[1] Univ Aveiro, Dept Chem, CICECO Aveiro Inst Mat, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Med Sci, IBiMED Inst Biomed, P-3810193 Aveiro, Portugal
[3] Portuguese Oncol Inst Porto GEBC CI IPOP, Res Ctr, Canc Biol & Epigenet Grp, P-4200072 Porto, Portugal
[4] Porto Comprehens Canc Ctr PCCC, P-4200072 Porto, Portugal
[5] Univ Porto, Fac Med, Cardiovasc R&D Ctr, Dept Surg & Physiol,UnIC RISE, P-4200319 Porto, Portugal
[6] Univ Aveiro, Chem Dept, LAQV REQUIMTE, Aveiro, Portugal
关键词
Dynamic light scattering; Magnetic nanoparticles; C-reactive protein; Saliva; Detection; IMMUNOASSAY; SALIVARY; MARKERS; RISK;
D O I
10.1016/j.aca.2022.340169
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we present a simple method for label-free detection of C-reactive protein (CRP) in diluted saliva samples without the use of specific molecules against CRP. We use the dynamic light scattering (DLS) technique and silica-coated Fe3O4 nanoparticles (similar to 50 nm in diameter) functionalized with amino carboxylate moieties (Fe3O4@SiO2/COOH) as probes. After contact with the sample, the particles could be easily separated with a handy magnet and redispersed for DLS analysis simply by vortex shaking. The variation of the hydrodynamic diameter of the nanoparticles (Z-average size) could be correlated with the concentration of CRP up to concentrations of 10 mg L-1. The detection limit (LOD) in diluted saliva samples that were spiked with CRP was 0.205 mg L-1, which is below salivary levels of CRP detected in unhealthy individuals. The coefficient of variation was found to be less than 1.5% in the entire detection range. The variation of Z-average size of nonfunctionalized silica coated nanoparticles (Fe3O4@SiO2) also correlated well with CRP concentration. Nevertheless, the Fe3O4@SiO2/COOH nanoparticles were less susceptible to interference from other biomolecules present in saliva and adsorbed more CRP, indicating higher selectivity toward CRP than nonfunctionalized nanoparticles. This higher affinity was attributed to the chelating interaction between the aminocarboxylate groups of the organosilane N-[3-(trimethoxysilyl)propyl]ethylenediaminetriacetic acid trisodium salt (EDTA-TMS) grafted onto the surface of the Fe3O4@SiO2/COOH nanoparticles and the Ca2+ ions of CRP. LC-MS/MS analyses allowed identification of the proteins adsorbed on the nanoparticles and confirmation of the presence of CRP, which is involved in several biological processes, including immune response, response to stress and transport.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] An ultrasensitive label-free immunoassay for C-reactive protein detection in human serum based on electron transfer
    Zhang, Xi
    Hu, Rong
    Zhang, Kunlei
    Bai, Ruyan
    Li, Delei
    Yang, Yunhui
    ANALYTICAL METHODS, 2016, 8 (32) : 6202 - 6207
  • [22] A New Device Based on Interferometric Optical Detection Method for Label-Free Screening of C-Reactive Protein
    Maigler, Maria V.
    Holgado, Miguel
    Fe Laguna, Maria
    Sanza, Francisco J.
    Santamaria, Beatriz
    Lavin, Alvaro
    Espinosa, Rocio L.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (09) : 3193 - 3199
  • [23] Acoustic Biosensors Coated With Phosphorylcholine Groups for Label-Free Detection of Human C-Reactive Protein in Serum
    Pomowski, Anett
    Baricham, Claudia
    Rapp, Bastian E.
    Matern, Andreas
    Laenge, Kerstin
    IEEE SENSORS JOURNAL, 2015, 15 (08) : 4388 - 4392
  • [24] Label-free and direct detection of C-reactive protein using reduced graphene oxide-nanoparticle hybrid impedimetric sensor
    Yagati, Ajay Kumar
    Pyun, Jae-Chul
    Min, Junhong
    Cho, Sungbo
    BIOELECTROCHEMISTRY, 2016, 107 : 37 - 44
  • [25] Free-Solution, Label-Free Protein-Protein Interactions Characterized by Dynamic Light Scattering
    Hanlon, Amy D.
    Larkin, Michael I.
    Reddick, Ryan M.
    BIOPHYSICAL JOURNAL, 2010, 98 (02) : 297 - 304
  • [26] Sensitive Affimer and Antibody Based Impedimetric Label-Free Assays for C-Reactive Protein
    Johnson, Anthony
    Song, Qifeng
    Ferrigno, Paul Ko
    Bueno, Paulo R.
    Davis, Jason J.
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6553 - 6560
  • [27] Detection of C-reactive protein using a label-free NIR fluorescent aptasensor with a large Stokes shift based on an AIEE anthracene derivative
    Fu, Zhuowei
    Yang, Yiwen
    Li, Zhifeng
    Zeng, Yanbo
    Wang, Hailong
    Han, Yifeng
    Tang, Qiukai
    Li, Lei
    ANALYTICA CHIMICA ACTA, 2025, 1333
  • [28] Label-free and quantitative analysis of C-reactive protein in human sera by tagged-internal standard assay on antibody arrays
    Jung, Jae-Wan
    Jung, Se-Hui
    Yoo, Je-Ok
    Suh, In-Bum
    Kim, Young-Myeong
    Ha, Kwon-Soo
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1469 - 1473
  • [29] Oriented Antibody Covalent Immobilization for Label-Free Impedimetric Detection of C-Reactive Protein via Direct and Sandwich Immunoassays
    Adesina, Abiola
    Mashazi, Philani
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [30] Real time and label-free detection of C-reactive protein in serum by long period grating in double cladding fiber
    Esposito, Flavio
    Sansone, Lucia
    Srivastava, Anubhav
    Baldini, Francesco
    Campopiano, Stefania
    Chiavaioli, Francesco
    Giordano, Michele
    Giannetti, Ambra
    Iadicicco, Agostino
    OPTICAL SENSORS 2021, 2021, 11772