Surface Tension Measurement by the Drop Volume Method

被引:1
|
作者
Du Dongxing [1 ]
Geng Diancai [1 ]
Sun Shijiao [1 ]
Li Yingge [2 ]
机构
[1] Qingdao Univ Sci & Technol, Shandong Prov Key Lab Polymer Mat Adv Mfg Technol, Qingdao 266061, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Automat & Elect Engn, Qingdao 266042, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
surface tension; the drop volume method; SDBS; Triton; foams; FOAM; WATER;
D O I
10.4028/www.scientific.net/KEM.501.407
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surface tension is one of the main physical parameters of foams. The surface tension of Sodium Dodecyl Benzene Sulfonate (SDBS) solution and Triton solution are measured by the drop volume method, and the CO2 saturated SDBS solution is also measured in this paper. It is found the solution concentration has an obvious effect on the surface tension. For SDBS solution, the surface tension gradually decreases with the increase of surfactant concentration while keeps constant after a certain concentration. For Triton solution, on the other hand, the surface tension always remains approximately constant in the studied concentration region. The surface tension of CO2 saturated SDBS solution is slightly higher than SDBS solution through experimental investigations.
引用
收藏
页码:407 / +
页数:3
相关论文
共 50 条
  • [21] Effects of injection angle on the measurement of surface tension coefficient by drop weight method
    Moradian, Ala
    Mostaghimi, Javad
    PHYSICS AND CHEMISTRY OF LIQUIDS, 2011, 49 (01) : 32 - 51
  • [22] Surface tension measurement of normal human blood samples by pendant drop method
    Yadav S.S.
    Sikarwar B.S.
    Ranjan P.
    Janardhanan R.
    Goyal A.
    Journal of Medical Engineering and Technology, 2020, 44 (05): : 227 - 236
  • [23] MEASUREMENT OF THE SURFACE TENSION OF TITANIFEROUS MOLTEN IRON BY THE SESSILE DROP METHOD.
    Luo, Weizhong
    Mao, Yuwen
    Huang, Lu
    Zhu, Yuankai
    Kang T'ieh/Iron and Steel (Peking), 1987, 22 (01): : 1 - 4
  • [24] Precise measurement of liquid viscosity and surface tension with an improved oscillating drop method
    Matsumoto, T
    Nakano, T
    Fujii, H
    Kamai, M
    Nogi, K
    PHYSICAL REVIEW E, 2002, 65 (03):
  • [25] SURFACE-TENSION OF WASTE-WATER SAMPLES MEASURED BY THE DROP VOLUME METHOD
    GUNDE, R
    DAWES, M
    HARTLAND, S
    KOCH, M
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) : 1036 - 1040
  • [26] Adsorption-equilibrium surface tension of surfactant solutions; Examination by the drop volume method
    Matsuki, Hitoshi
    Yamanaka, Michio
    Yamashita, Yuji
    Kaneshina, Shoji
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2006, 79 (11) : 1704 - 1710
  • [27] Adsorption-equilibrium surface tension of surfactant solutions; examination by the drop volume method
    Matsuki, Hitoshi
    Yamanaka, Michio
    Yamashita, Yuji
    Kaneshina, Shoji
    Bulletin of the Chemical Society of Japan, 2006, 79 (11): : 1704 - 1710
  • [28] AUTOMATIC SURFACE-TENSION MEASUREMENTS OF AQUEOUS SURFACTANT SOLUTIONS BY THE DROP VOLUME METHOD
    MATSUKI, H
    KANESHINA, S
    YAMASHITA, Y
    MOTOMURA, K
    LANGMUIR, 1994, 10 (11) : 4394 - 4396
  • [29] Measurement of surface tension by sessile drop tensiometer with superoleophobic surface
    Kwak, Wonshik
    Park, Junkwon
    Yoon, Jinsung
    Lee, Sanghyun
    Hwang, Woonbong
    APPLIED PHYSICS LETTERS, 2018, 112 (12)
  • [30] Comments on the drop method of measuring surface tension and interfacial tension
    Traube, J
    KOLLOID-ZEITSCHRIFT, 1930, 53 (03): : 300 - 303