Analysis of Power Factor Over Correction in a Distribution Feeder

被引:0
|
作者
Bastos, Alvaro Furlani [1 ]
Santoso, Surya [1 ]
Biyikli, Levent [2 ]
机构
[1] Univ Texas Austin, Austin, TX 78712 USA
[2] 3M Co, Maplewood, MN USA
关键词
capacitor bank energizing; power factor correction; power quality; power system loss; power system transients;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Capacitor banks are commonly connected to the power system to enhance its reliability by providing voltage support, improving power factor, and increasing the system capacity. They are usually switched in and out of the system according to the amount of connected load. This paper analyzes measurement data of a distribution utility with capacitor banks located downstream from the power quality monitor. It was observed that the amount of reactive power injected into the system was larger than the necessary, resulting in power factor over correction. The paper then provides an analysis method to determine the capacitor bank size to achieve a desired power factor correction. An algorithm is also proposed to override a switching control (usually time, voltage, or temperature), such that the switching is performed only if the power factor is below a preset minimum value. Moreover, it is advised to switch each phase individually, as the reactive power flow differs significantly between the three phases.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] IMPACT OF RESIDENTIAL PHOTOVOLTAIC POWER-SYSTEMS ON THE DISTRIBUTION FEEDER
    FITZER, J
    DILLON, WE
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1986, 1 (04) : 39 - 42
  • [42] Power factor correction devices
    Valshin, AM
    Vildanov, RR
    APEDE 2004: INTERNATIONAL CONFERENCE ON ACTUAL PROBLEMS OF ELECTRON DEVICES ENGINEERING, CONFERENCE PROCEEDINGS, 2004, : 319 - 323
  • [43] Reliability Improvement of Power Distribution System Through Feeder Reconfiguration
    Elsaiah, Salem
    Benidris, Mohammed
    Mitra, Joydeep
    2014 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS (PMAPS), 2014,
  • [44] Harmonic and noise propagation on cascaded sections of a power distribution feeder
    Gajjar, JT
    ICCDCS 98: PROCEEDINGS OF THE 1998 SECOND IEEE INTERNATIONAL CARACAS CONFERENCE ON DEVICES, CIRCUITS AND SYSTEMS, 1998, : 426 - 430
  • [45] Reliability Constrained Distribution Feeder Reconfiguration for Power Loss Minimization
    Jose, Joel
    Kowli, Anupama
    2016 NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2016,
  • [46] POWER-FACTOR CORRECTION
    不详
    ELECTRONIC PRODUCTS MAGAZINE, 1990, 33 (03): : 42 - 42
  • [47] Power factor correction:: A survey
    García, O
    Cobos, JA
    Prieto, R
    Alou, P
    Uceda, J
    PESC 2001: 32ND ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2001, : 8 - 13
  • [48] Stepless power factor correction
    Rohatyn, Frederick, 1600, (90):
  • [49] Reactive Power Control Strategy for Voltage Regulation and Power-Factor Correction in MV Distribution Networks
    Gatta, F. M.
    Geri, A.
    Maccioni, M.
    Mantineo, A.
    Cresta, M.
    Paulucci, M.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [50] Correction of the power factor of secondary power supplies
    Magazinnik, A.G.
    Magazinnik, L.T.
    Magazinnik, G.G.
    Elektrotekhnika, 2001, (05): : 40 - 42