Optimizing the use of point of care testing devices for screening patients

被引:4
|
作者
Sarraf, Elie [1 ]
Mathews, Donald M. [1 ]
Tsai, Mitchell H. [1 ,2 ,3 ]
Goodwin, Andrew J. [4 ]
机构
[1] Univ Vermont, Dept Anesthesiol, Larner Coll Med, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Surg Courtesy, Larner Coll Med, Burlington, VT 05405 USA
[3] Univ Vermont, Dept Orthopaed & Rehabil Courtesy, Larner Coll Med, Burlington, VT USA
[4] Univ Vermont, Dept Pathol & Lab Med, Larner Coll Med, Burlington, VT USA
关键词
Point of Care Testing; Screening; Cost containment; ACCURACY;
D O I
10.1007/s10877-019-00332-w
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Point of Care Testing (POCT) devices are regularly used to improve clinical workflows in the hospital setting despite generally having inferior performance when compared to standardized laboratory analyzers. We describe a method to improve the efficacy of using a POCT device as a screening test when the laboratory values occur over a continuum and applied this methodology to the process of International Normalized Ratios (INR) screening on day of surgery. Following IRB approval, laboratory INR values on the day of surgery were extracted from the University of Vermont Medical Center operating room's electronic health record. Two separate theoretical POCT device values were simulated from the performance characterized by two prior publications (Jacobson and Hur). The sensitivities and specificities of the two theoretical devices were calculated over a range of values, in order detect an INR value greater or equal than 1.5 and 1.8. Subsequently, the percentage of the population with an INR value over each threshold was also calculated. Laboratory data from March 2008 to December 2016 were collected, and 9320 discrete INR values were compiled ranging from 0.8 to > 20. Two POCT devices were simulated using that dataset. The sensitivities and specificities over a range of values were determined, and the optimal cutoff values were identified for each device separately. Calculating the sensitivities and specificities over a range of values can optimize the clinical efficacy of a POCT device. By optimizing the use of POCT devices, hospitals may be able to improve clinical processes and reduce costs.
引用
收藏
页码:411 / 419
页数:9
相关论文
共 50 条
  • [41] Use of point-of-care testing for respiratory viruses in hospital
    Hayward, Andrew C.
    LANCET RESPIRATORY MEDICINE, 2021, 9 (04): : 324 - 326
  • [42] Optimizing Point-of-Care Testing for Diabetes Management in a Rural Australian General Practice
    Motta, Lara A.
    Shephard, Mark D. S.
    Halls, Heather J.
    Barnes, Glennis
    Senior, John
    POINT OF CARE, 2015, 14 (01): : 25 - 31
  • [43] Portable devices and mobile instruments for infectious diseases point-of-care testing
    Bissonnette, Luc
    Bergeron, Michel G.
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2017, 17 (05) : 471 - 494
  • [44] Katrina, the tsunami, and point-of-care testing: Optimizing rapid response diagnosis in disasters
    Kost, Gerald J.
    Tran, Nam K.
    Tuntideelert, Masarus
    Kulrattanamaneeporn, Shayanisawa
    Peungposop, Narisara
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (04) : 513 - 520
  • [45] Materials-Functionalized Point-of-Care Testing Devices for Pathogen Detection
    Wang, Han
    Wang, Yingfei
    Wang, Wenjie
    Zhang, Yun
    Yuan, Quan
    Tan, Jie
    ACCOUNTS OF MATERIALS RESEARCH, 2023, 4 (12): : 1083 - 1094
  • [46] Point-of-Care Testing (POCT) Devices for DNA Detection: A Comprehensive Review
    Mahardika, Ignasia Handipta
    Naorungroj, Sarida
    Khamcharoen, Wisarut
    Kin, Sarath
    Rodthongkum, Nadnudda
    Chailapakul, Orawon
    Shin, Kwanwoo
    ADVANCED NANOBIOMED RESEARCH, 2023, 3 (11):
  • [47] A Label-Free and Affordable Solution to Point-of-Care Testing Devices
    Lee, Mon-Juan
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [48] Integrated paper-based microfluidic devices for point-of-care testing
    Tian, Tian
    Bi, Yunpeng
    Xu, Xing
    Zhu, Zhi
    Yang, Chaoyong
    ANALYTICAL METHODS, 2018, 10 (29) : 3567 - 3581
  • [49] Evaluation of two devices for point-of-care testing of haemoglobin in neonatal pigs
    Kutter, Annette P. N.
    Mauch, Jacqueline Y.
    Riond, Barbara
    Martin-Jurado, Olga
    Spielmann, Nelly
    Weiss, Markus
    Bettschart-Wolfensberger, Regula
    LABORATORY ANIMALS, 2012, 46 (01) : 65 - 70
  • [50] Point of care testing
    Aulois-Griot, M
    Billion, P
    Calestreme, P
    Coquelin, H
    Daunizeau, A
    Del Corso, A
    Duchassaing, D
    Jacob, JL
    Lafond, JL
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (01) : 114 - 115