作者
Sarraf, Elie [1 ]
Mathews, Donald M. [1 ]
Tsai, Mitchell H. [1 ,2 ,3 ]
Goodwin, Andrew J. [4 ]
机构
[1] Univ Vermont, Dept Anesthesiol, Larner Coll Med, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Surg Courtesy, Larner Coll Med, Burlington, VT 05405 USA
[3] Univ Vermont, Dept Orthopaed & Rehabil Courtesy, Larner Coll Med, Burlington, VT USA
[4] Univ Vermont, Dept Pathol & Lab Med, Larner Coll Med, Burlington, VT USA
关键词
Point of Care Testing; Screening; Cost containment; ACCURACY;
D O I
10.1007/s10877-019-00332-w
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Point of Care Testing (POCT) devices are regularly used to improve clinical workflows in the hospital setting despite generally having inferior performance when compared to standardized laboratory analyzers. We describe a method to improve the efficacy of using a POCT device as a screening test when the laboratory values occur over a continuum and applied this methodology to the process of International Normalized Ratios (INR) screening on day of surgery. Following IRB approval, laboratory INR values on the day of surgery were extracted from the University of Vermont Medical Center operating room's electronic health record. Two separate theoretical POCT device values were simulated from the performance characterized by two prior publications (Jacobson and Hur). The sensitivities and specificities of the two theoretical devices were calculated over a range of values, in order detect an INR value greater or equal than 1.5 and 1.8. Subsequently, the percentage of the population with an INR value over each threshold was also calculated. Laboratory data from March 2008 to December 2016 were collected, and 9320 discrete INR values were compiled ranging from 0.8 to > 20. Two POCT devices were simulated using that dataset. The sensitivities and specificities over a range of values were determined, and the optimal cutoff values were identified for each device separately. Calculating the sensitivities and specificities over a range of values can optimize the clinical efficacy of a POCT device. By optimizing the use of POCT devices, hospitals may be able to improve clinical processes and reduce costs.
引用
收藏
页码:411 / 419
页数:9
相关论文
共 50 条
  • [1] Optimizing the Use of Point of Care Testing Devices for Screening Patients
    Sarraf, Elie
    Mathews, Donald M.
    ANESTHESIA AND ANALGESIA, 2017, 124 : 1125 - 1127
  • [2] Optimizing the use of point of care testing devices for screening patients
    Elie Sarraf
    Donald M. Mathews
    Mitchell H. Tsai
    Andrew J. Goodwin
    Journal of Clinical Monitoring and Computing, 2020, 34 : 411 - 419
  • [3] Electrochemiluminescence devices for point-of-care testing
    Ying, Xudong
    Zhou, Lin
    Fu, Wenxuan
    Wang, Yafeng
    Su, Bin
    SENSORS & DIAGNOSTICS, 2023, 2 (03): : 480 - 491
  • [4] Innovative Use of Point-of-Care Testing for Chronic Kidney Disease Screening
    Shephard, Anne K.
    Shephard, Mark D. S.
    Halls, Heather J.
    Corso, Olivia
    Mathew, Timothy H.
    POINT OF CARE, 2011, 10 (02): : 98 - 101
  • [5] Flexible Analytical Devices for Point-of-Care Testing
    Tsutsui, Hideaki
    Lillehoj, Peter B.
    SLAS TECHNOLOGY, 2020, 25 (01): : 6 - 8
  • [6] Blood Gas Measurements Using Point-of-Care Testing Devices in Pediatric Patients
    Teksoz, Duygu
    Isiksacan, Nilgun
    Koser, Murat
    ISTANBUL MEDICAL JOURNAL, 2024, 25 (03): : 245 - 249
  • [7] Advances in the use of nanomaterials for nucleic acid detection in point-of-care testing devices: A review
    He, Ziyu
    Liu, Changsheng
    Li, Zhongyu
    Chu, Zhou
    Chen, Xiang
    Chen, Xupeng
    Guo, Yuan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [8] Accuracy of anemia screening by point-of-care hemoglobin testing in patients seeking abortion
    Shapiro, Katherine E.
    Buhimschi, Irina A.
    Fleisher, Jonah
    CONTRACEPTION, 2022, 105 : 51 - 54
  • [9] Evaluation of point of care coagulation devices for INR testing.
    Beyer, LK
    Sorenson, LL
    Deobald, GR
    Newton, NC
    Santrach, PJ
    CLINICAL CHEMISTRY, 2001, 47 (06) : A187 - A187
  • [10] Recent advances in electrochemiluminescence devices for point-of-care testing
    Gao, Wenyue
    Saqib, Muhammad
    Qi, Liming
    Zhang, Wei
    Xu, Guobao
    CURRENT OPINION IN ELECTROCHEMISTRY, 2017, 3 (01) : 4 - 10