Study of pulsed electron cyclotron resonance ion source plasma near breakdown: The preglow

被引:19
|
作者
Thuillier, T. [1 ]
Lamy, T. [1 ]
Latrasse, L. [1 ]
Lzotov, I. V. [2 ]
Sidorov, A. V. [2 ]
Skalyga, V. A. [2 ]
Zorin, V. G. [2 ]
Marie-Jeanne, M. [3 ]
机构
[1] Univ Grenoble 1, Lab Phys Subatom Cosmol, CNRS, IN2P3, F-38026 Grenoble, France
[2] IAP, Nizhnii Novgorod 603950, Russia
[3] CERN, Dept Phys, CH-1211 Geneva, Switzerland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 02期
基金
俄罗斯基础研究基金会;
关键词
D O I
10.1063/1.2821503
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A careful study of pulsed mode operation of the PHOENIX electron cyclotron resonance (ECR) ion source has clearly demonstrated the reality of an unexpected transient current peak, occurring at the very beginning of the plasma breakdown. This regime was named the preglow, as an explicit reference to the afterglow occurring at the microwave pulse end. After the transient preglow peak, the plasma regime relaxes to the classical steady state one. Argon preglow experiments performed at LPSC are presented. A theoretical model of ECR gas breakdown in a magnetic trap, developed at IAP, showing satisfactory agreement with the experimental results is suggested. (c) 2008 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A simple electron cyclotron resonance ion source
    Welton, RF
    Moran, TF
    Feeney, RK
    Thomas, EW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (04): : 1634 - 1637
  • [22] Electron cyclotron resonance negative ion source
    Fukumasa, O
    Matsumori, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 935 - 938
  • [23] Design of a small electron cyclotron resonance ion source with partially pulsed magnetic field
    Oyaizu, M
    Tojyo, E
    Jeong, SC
    Ishiyama, H
    Miyatake, H
    Ishida, Y
    Kawakami, H
    Katayama, I
    Nomura, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1113 - 1115
  • [24] Characteristics of an electron cyclotron resonance plasma source
    Liu, Zhongyang
    Sun, Guanqing
    Zhang, Dazhong
    Chen, Jianxuan
    Zhong, Guangwu
    He Jishu/Nuclear Techniques, 2000, 23 (10): : 707 - 712
  • [25] AN ELECTRON-CYCLOTRON RESONANCE PLASMA SOURCE
    LORENZ, G
    BAUMANN, P
    CASTRISCHER, G
    KESSLER, I
    KRETSCHMER, KH
    DUMBACHER, B
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1991, 139 : 302 - 306
  • [26] Compact electron cyclotron resonance plasma source
    Gaudin, C
    Hay, L
    Buzzi, JM
    Bacal, M
    Lamoureux, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 890 - 892
  • [27] Plasma density measurement of electron cyclotron resonance ion source for neutron generator
    Yuan, Yu-Fei
    Meng, Lin
    Zhou, Chang-Geng
    Hu, Yong-Hong
    Zhang, Qin-Long
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2007, 19 (12): : 2095 - 2098
  • [28] Electron cyclotron resonance plasma source for ion assisted deposition of thin films
    Vargheese, KD
    Rao, GM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 467 - 472
  • [29] Electromagnetic simulation of an electron cyclotron resonance ion source considering plasma effects
    Kim, Deok-Min
    Hong, In-Seok
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2025, 86 (03) : 173 - 179
  • [30] Compact electron cyclotron resonance plasma source optimization for ion beam applications
    O'Keeffe, Patrick
    Yamakawa, Kouji
    Mutoh, Harunobu
    Den, Shoji
    Hayashi, Yuzo
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (7 B): : 4576 - 4582