Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis

被引:8
|
作者
Tana, P
Belmonte, J
机构
[1] Servicio de Oftalmologia, Hosp. General Univ. de Alicante SVS, 03010 Alicante
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 1996年 / 22卷 / 09期
关键词
D O I
10.1016/S0886-3350(96)80070-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To analyze experimentally in cadaver eyes several models of commercially available posterior chamber intraocular lenses (IOLs) to determine their stability, fixation, and behavior in the capsular bag in relation to their overall size, optic diameter, shape, material, and haptic configuration. Setting: Eye Bank and Department of Ophthalmology, University General Hospital of Alicante, Spain. Methods: Thirty-three IOLs of different sizes, shapes, and designs, divided in two series and five groups, were implanted successively in 31 cadaver eyes. All the proceedings were videotaped, and measurements were made on the television screen with the picture static. Main outcome measures were the diameters of the lens, the empty capsular bag, and the capsulorhexis; capsular distension by the IOL haptics; extent of haptic are of contact with the capsular equator; and IOL mobility in the bag. Results: The stability of and stretching caused by the IOLs varied greatly depending on their overall size, haptic flexibility and the extent of the are of haptic contact with the capsular equator. Lenses between 13.5 and 14.0 mm had good stability but stretched the capsule excessively. The J-loop haptic configuration produced a spindle-shaped bag deformity that might come in contact with the ciliary processes in the physiologic eye. Among IOLs designed for in-the-bag implantation after capsulorhexis, the two smaller than 12.0 mm were unstable, permitting excessive mobility in the capsular bag. Except for IOLs with a 5.0 mm optic, all 12.0 mm IOLs had reasonable stability, little or no mobility within the capsular bag, and good short-term centering. Lenses with a broad angulation at the haptic-optic junction, to about 90 degrees, achieved the largest are of contact with the equator and behaved as lenses with larger optics. The Pharmacia 808 performed best. Conclusion: After capsulorhexis and extracapsular cataract extraction, 12.0 mm, poly(methyl methacrylate), one-piece IOLs with modified C-shaped loops, 90 degree angulation at the haptic-optic junction, and an optic diameter between 6.0 and 6.5 mm performed best in the capsular bag.
引用
收藏
页码:1211 / 1221
页数:11
相关论文
共 50 条
  • [21] Monochromatic aberrations in eyes with different intraocular lens optic designs
    Padmanabhan, P
    Rao, SK
    Jayasree, R
    Chowdhry, M
    Roy, J
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 172 - 177
  • [22] ANATOMICAL CHANGES OF THE CAPSULAR BAG AFTER LENS REMOVAL AND INTRAOCULAR-LENS IMPLANTATION
    ASSIA, EI
    LEGLER, UFC
    CASTANEDA, VE
    HOGGATT, JP
    APPLE, DJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 797 - 797
  • [23] In-the-bag intraocular lens exchange 13 years after refractive lens extraction
    Roelofs, Kelsey
    Rudnisky, Chris
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2016, 51 (06): : E161 - E163
  • [24] Incidence of rhegmatogenous retinal detachment after bag-in-the-lens intraocular lens implantation
    Tassignon, Marie-Jose
    Van den Heurck, Jonas J. I.
    Boven, Kim B. M.
    Van Looveren, Jan
    Wouters, Kristien
    Bali, Ernesto
    Dhubhghaill, Sorcha Ni
    Mathysen, Danny G. P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (11): : 2430 - 2437
  • [25] Intraocular lens tilt and decentration after Nd:YAG laser posterior capsulotomy: Femtosecond laser capsulorhexis versus manual capsulorhexis
    Cinar, Esat
    Yuce, Berna
    Aslan, Fatih
    Erbakan, Gokhan
    Kucukerdonmez, Cem
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1637 - 1644
  • [26] Intraocular pressure changes before and after surgery for spontaneous in-the-bag intraocular lens dislocation
    Lorente Bulnes, Betty
    de Rojas Silva, M. Victoria
    Lorente Moore, Ramon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03): : 305 - 311
  • [27] EFFECT OF INTRAOCULAR-LENS DESIGN ON POSTERIOR CAPSULE OPACIFICATION AFTER CONTINUOUS CURVILINEAR CAPSULORHEXIS
    YAMADA, K
    NAGAMOTO, T
    YOZAWA, H
    KATO, K
    KUROSAKA, D
    MIYAJIMA, HB
    KIMURA, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (06): : 697 - 700
  • [28] Clinical results after spherotoric intraocular lens implantation using the bag-in-the-lens technique
    Tassignon, Marie-Jose
    Gobin, Laure
    Mathysen, Danny
    Van Looveren, Jan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05): : 830 - 834
  • [29] Surgically induced astigmatism after intraocular lens implantation using the bag-in-the-lens technique
    Gobin, Laure
    Tassignon, Marie-Jose
    Wouters, Kristien
    De Groot, Veva
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1015 - 1019
  • [30] Optical aberrations in three different intraocular lens designs of a same platform
    Bartol-Puyal, Francisco A.
    Gimenez, Galadriel
    Altemir, Irene
    Larrosa, Jose
    Polo, Vicente
    Pablo, Luis
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2021, 35 (02) : 126 - 130