Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis

被引:8
|
作者
Tana, P
Belmonte, J
机构
[1] Servicio de Oftalmologia, Hosp. General Univ. de Alicante SVS, 03010 Alicante
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 1996年 / 22卷 / 09期
关键词
D O I
10.1016/S0886-3350(96)80070-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To analyze experimentally in cadaver eyes several models of commercially available posterior chamber intraocular lenses (IOLs) to determine their stability, fixation, and behavior in the capsular bag in relation to their overall size, optic diameter, shape, material, and haptic configuration. Setting: Eye Bank and Department of Ophthalmology, University General Hospital of Alicante, Spain. Methods: Thirty-three IOLs of different sizes, shapes, and designs, divided in two series and five groups, were implanted successively in 31 cadaver eyes. All the proceedings were videotaped, and measurements were made on the television screen with the picture static. Main outcome measures were the diameters of the lens, the empty capsular bag, and the capsulorhexis; capsular distension by the IOL haptics; extent of haptic are of contact with the capsular equator; and IOL mobility in the bag. Results: The stability of and stretching caused by the IOLs varied greatly depending on their overall size, haptic flexibility and the extent of the are of haptic contact with the capsular equator. Lenses between 13.5 and 14.0 mm had good stability but stretched the capsule excessively. The J-loop haptic configuration produced a spindle-shaped bag deformity that might come in contact with the ciliary processes in the physiologic eye. Among IOLs designed for in-the-bag implantation after capsulorhexis, the two smaller than 12.0 mm were unstable, permitting excessive mobility in the capsular bag. Except for IOLs with a 5.0 mm optic, all 12.0 mm IOLs had reasonable stability, little or no mobility within the capsular bag, and good short-term centering. Lenses with a broad angulation at the haptic-optic junction, to about 90 degrees, achieved the largest are of contact with the equator and behaved as lenses with larger optics. The Pharmacia 808 performed best. Conclusion: After capsulorhexis and extracapsular cataract extraction, 12.0 mm, poly(methyl methacrylate), one-piece IOLs with modified C-shaped loops, 90 degree angulation at the haptic-optic junction, and an optic diameter between 6.0 and 6.5 mm performed best in the capsular bag.
引用
收藏
页码:1211 / 1221
页数:11
相关论文
共 50 条
  • [1] Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation - Experimental study in pediatric human eyes
    Pandey, SK
    Werner, L
    Wilson, ME
    Izak, AM
    Apple, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2183 - 2191
  • [2] Repositioning surgery of different intraocular lens designs in eyes with late in-the-bag intraocular lens dislocation
    Dalby, Marius
    Drolsum, Liv
    Kristianslund, Olav
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (09): : 1147 - 1152
  • [3] Capsulorhexis phimosis after bimanual microphacoemulsification and in-the-bag implantation of the Akreos MI60 intraocular lens
    Cavallini, Gian Maria
    Masini, Cristina
    Campi, Luca
    Pelloni, Simone
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1598 - 1600
  • [4] Single suture iris-to-capsulorhexis fixation for in-the-bag intraocular lens subluxation
    Siegel, Michael J.
    Condon, Garry P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (11): : 2347 - 2352
  • [5] Late complications with intraocular lens dislocation after capsulorhexis in pseudoexfoliation syndrome
    Masket, S
    Osher, RH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (08): : 1481 - 1484
  • [6] A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
    Takada, Yukihisa
    Sumioka, Takayoshi
    Ishikawa, Nobuyuki
    Yasuda, Shingo
    Komori, Ryoko
    Saika, Shizuya
    CASE REPORTS IN OPHTHALMOLOGY, 2020, 11 (01): : 60 - 67
  • [8] Cumulative neodymium:YAG laser rates after bag-in-the-lens and lens-in-the-bag intraocular lens implantation -: Comparative study
    Leysen, Inge
    Coeckelbergh, Tanja
    Gobin, Laure
    Smet, Helena
    Daniel, Yves
    De Groot, Veva
    Tassignon, Marie-Jose
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12): : 2085 - 2090
  • [9] In-the-bag hyphema after intraocular lens implantation
    Ohmi, S
    Takagishi, C
    Hashizume, N
    Saika, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (06): : 755 - 758
  • [10] In-the-Bag Intraocular Lens Placement via Secondary Capsulorhexis with Radiofrequency Diathermy in Pediatric Aphakic Eyes
    Luo, Lixia
    Lin, Haotian
    Chen, Weirong
    Wang, Chunxiao
    Zhang, Xinyu
    Tang, Xiangchen
    Liu, Jianping
    Congdon, Nathan
    Chen, Jingjing
    Lin, Zhuoling
    Liu, Yizhi
    PLOS ONE, 2013, 8 (04):