Rapid diagnosis of Plasmodium falciparum malaria using a point-of-care loop-mediated isothermal amplification device

被引:9
|
作者
Puri, Madhu [1 ]
Kaur Brar, Harsimran [1 ]
Madan, Evanka [1 ]
Srinivasan, Rajesh [2 ]
Rawat, Kapil [2 ]
Gorthi, Sai Siva [2 ]
Kumari, Geeta [3 ]
Sah, Raj [3 ]
Ojha, Sashi Bhusan [4 ]
Panigrahi, Subhendu [5 ]
Dhangadamajhi, Gunanidhi [4 ]
Muthuswami, Rohini [1 ]
Singh, Shailja [3 ]
Madhubala, Rentala [1 ]
机构
[1] Jawaharlal Nehru Univ, Sch Life Sci, New Delhi, India
[2] Indian Inst Sci, Dept Instrumentat & Appl Phys, Bengaluru, India
[3] Jawaharlal Nehru Univ, Special Ctr Mol Med, New Delhi, India
[4] Maharaja Sriram Chandra Bhanjadeo Univ, Dept Biotechnol, Baripada, India
[5] VSS Med Coll & Hosp, Dept Gen Med, Sambalpur, India
关键词
LAMP; plasmodium falciparum; diagnosis; LOD; parasite density; ADC value; IDENTIFICATION; ENDEMICITY; PARASITES; SAMPLES; PCR;
D O I
10.3389/fcimb.2022.961832
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
LAMP diagnosis of malaria is simple and cost-effective with acceptable sensitivity and specificity as compared to standard diagnostic modules such as microscopy, RDTs and nested PCR, and thus its deployment for onsite screening of malaria in resource-limited regions is under consideration. However, the requirement of an electricity-operated dry bath and bulky read-out unit is still a major concern. In an effort to simplify this limitation, we have developed a portable LAMP device and fluorescence readout unit which can be used in the rapid point-of-care diagnosis of malaria. We have developed a point-of-care diagnostic LAMP device that is easy to operate by a mobile application, and the results can be quantified with a fluorescent readout unit. The diagnostic performance of the device was evaluated in 90 P. falciparum-infected clinical isolates stored at 4 degrees C for 6-7 years and 10 freshly collected isolates from healthy volunteers. The LOD and quantitative ability of LAMP in estimating parasitemia levels were revealed with laboratory-grown P. falciparum strain (3D7). The LAMP assay performed in our device was exclusive for P. falciparum detection with sensitivity and specificity determined to be 98.89% and 100%, respectively, in clinical isolates. The LOD was documented to be 1 parasite/mu l at the cut-off ADC value of 20. Parasite density estimated from ADC values showed concordance with microscopically determined parasite density of the cultured P. falciparum 3D7 strain. The LAMP assay performed in our device provides a possible portable platform for its deployment in the point-of-care diagnosis of malaria. Further validation of the quantitative ability of the assay with freshly collected or properly stored clinical samples of known parasitemia is necessary for field applicability.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [42] Loop-Mediated Isothermal Amplification for Rapid and Reliable Diagnosis of Tuberculous Meningitis
    Nagdev, Khushboo J.
    Kashyap, Rajpal S.
    Parida, Manmohan M.
    Kapgate, Rajkumar C.
    Purohit, Hemant J.
    Taori, Girdhar M.
    Daginawala, Hatim F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (05) : 1861 - 1865
  • [43] Development of a loop-mediated isothermal amplification for rapid diagnosis of Aphelenchoides ritzemabosi
    Wang, Dong-Wei
    Xu, Chun-Ling
    Bai, Zong-Shi
    Li, Jun-Yi
    Han, Yu-Chun
    Zhao, Li-Rong
    Xie, Hui
    EUROPEAN JOURNAL OF PLANT PATHOLOGY, 2019, 155 (01) : 173 - 179
  • [44] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis Reply
    Sharma, Kusum
    Sharma, Aman
    Gupta, Amod
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : 226 - 226
  • [45] Rapid and sensitive diagnosis of Acanthamoeba keratitis by loop-mediated isothermal amplification
    Ge, Z.
    Qing, Y.
    Zicheng, S.
    Shiying, S.
    CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (11) : 1042 - 1048
  • [46] Rapid and sensitive diagnosis of Acanthamoeba keratitis by loop-mediated isothermal amplification
    Zhao, Ge
    Yuan, Qing
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [47] Development of a loop-mediated isothermal amplification for rapid diagnosis of Aphelenchoides ritzemabosi
    Dong-Wei Wang
    Chun-Ling Xu
    Zong-Shi Bai
    Jun-Yi Li
    Yu-Chun Han
    Li-Rong Zhao
    Hui Xie
    European Journal of Plant Pathology, 2019, 155 : 173 - 179
  • [48] Point-of-care testing based on colorimetric loop-mediated isothermal amplification coupled with a nondestructive device for rapid detection of Kudoa septempunctata in live olive flounder
    Lee, Jeong-Eun
    Yang, Hee-Kyeong
    Ha, Kwang-Soo
    Kim, Young-Mog
    Chang, Ji Yoon
    Shim, Won-Bo
    AQUACULTURE, 2025, 596
  • [49] Loop-Mediated Isothermal Amplification Technology: Towards Point of Care Diagnostics
    Njiru, Zablon Kithinji
    PLOS NEGLECTED TROPICAL DISEASES, 2012, 6 (06):
  • [50] Evaluation of WarmStart Colorimetric Loop-Mediated Isothermal Amplification Assay for Diagnosis of Malaria
    Lai, Meng Yee
    Ooi, Choo Huck
    Jaimin, Joel Judson
    Lau, Yee Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2020, 102 (06): : 1370 - 1372