On-site non-destructive determination of the remanent magnetization of archaeological finds using field magnetometers

被引:4
|
作者
Wunderlich, Tina [1 ,2 ]
Kahn, Raphael [1 ,2 ]
Nowaczyk, Norbert R. [3 ]
Pickartz, Natalie [1 ,2 ]
Schulte-Kortnack, Detlef [1 ,2 ]
Hofmann, Robert [2 ,4 ]
Rabbel, Wolfgang [1 ,2 ]
机构
[1] Univ Kiel, Inst Geosci, Otto Hahn Pl 1, D-24118 Kiel, Germany
[2] Univ Kiel, Collaborat Res Ctr 1266, Kiel, Germany
[3] GFZ German Res Ctr Geosci, Helmholtz Ctr Potsdam, Potsdam, Germany
[4] Univ Kiel, Inst Pre & Protohist Archaeol, Kiel, Germany
关键词
archaeology; linear inversion; magnetic modelling; remanent magnetization; susceptibility;
D O I
10.1002/arp.1847
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
The determination of the natural remanent magnetization (NRM) of archaeological features can be used for magnetic modelling, joining of shards, archaeomagnetic dating or the investigation of the firing-cooling-collapsing order of ancient buildings. The measurement of NRM is normally conducted on cylindrical or cubic samples in the laboratory. Nevertheless, archaeological finds should preferably not be destroyed, and laboratory instruments are high in costs. Therefore, we propose a lightweight and portable measurement set-up including already available field magnetometers (preferably caesium magnetometers) in which the archaeological sample of arbitrary shape, in our case a piece of daub, is mounted inside a gimbal to be rotated in all directions. The magnetic field of the sample is measured at a large number of rotational positions with the magnetometer kept at fixed position. In these measurements, the unknown direction of the NRM vector of the sample is rotated, whereas the average magnetic susceptibility of the sample and the ambient magnetic field are constant and known. Hence, the vector of NRM can be determined through least-squares inversion. For the inversion computation, the sample volume is discretized either as voxel model or approximated as an equivalent sphere. Under certain conditions depending on sample-sensor distance, dipole moment and radius of the sample, the approximation by a sphere is valid without effect on the accuracy of results. Empirically determined functions quantifying these conditions for different sensor sensitivities and noise levels are provided. Validation with laboratory measurements on palaeomagnetic subsamples from the destroyed daub samples indicate that the NRM can be determined by our proposed method with a maximum error in inclination of 2 degrees, in declination of 20 degrees and in magnetization of +/- 0.6 A/m. This is accurate enough, for example, to determine from daub pieces of burnt house remains whether the building was burnt and cooled before or after it collapsed.
引用
收藏
页码:205 / 227
页数:23
相关论文
共 50 条
  • [41] Leaf nitrogen determination using non-destructive techniques-A review
    Ali, M. M.
    Al-Ani, Ahmed
    Eamus, Derek
    Tan, Daniel K. Y.
    JOURNAL OF PLANT NUTRITION, 2017, 40 (07) : 928 - 953
  • [42] High aspect ratio depth determination using non-destructive AFM
    Jaiprakash, VC
    Lagus, ME
    Meyyappan, A
    Muckenhirn, S
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIII, PTS 1 AND 2, 1999, 3677 : 10 - 17
  • [43] NON-DESTRUCTIVE DETERMINATION OF ALUMINUM IN BIOLOGICAL REFERENCE SAMPLES USING NAA
    LANDSBERGER, S
    ARENDT, AM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1989, 137 (06): : 443 - 454
  • [44] Quantitative non-destructive determination of trace elements in archaeological pottery using a portable beam stability-controlled XRF spectrometer
    Romano, FP
    Pappalardo, G
    Pappalardo, L
    Garraffo, S
    Gigli, R
    Pautasso, A
    X-RAY SPECTROMETRY, 2006, 35 (01) : 1 - 7
  • [45] Analysis of baseball bats performance using field and non-destructive tests
    Smith, R. W.
    Liu, T. H.
    Shiang, T. Y.
    IMPACT OF TECHNOLOGY ON SPORTS II, 2008, : 363 - 369
  • [46] On-site non-destructive mid-IR spectroscopy of plastics in museum objects using a portable FTIR spectrometer with fiber optic probe
    Williams, RS
    MATERIALS ISSUES IN ART AND ARCHAEOLOGY V, 1997, 462 : 25 - 30
  • [47] Development of the neutron salt-meter RANS-μ for non-destructive inspection of concrete structure at on-site use
    Wakabayashi, Yasuo
    Yan, Mingfei
    Takamura, Masato
    Ooishi, Ryuutarou
    Watase, Hiroshi
    Ikeda, Yujiro
    Otake, Yoshie
    JOURNAL OF NEUTRON RESEARCH, 2022, 24 (3-4) : 411 - 419
  • [48] Development of a Non-destructive Method to Measure the On-Site Clamping Force of Torque Shear High-Strength Bolts
    Nah, Hwan Seon
    Jung, Hoon
    Lee, Hyeon Ju
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2018, 38 (02) : 126 - 134
  • [49] Determination of chloride content in concrete using near- and far-field microwave non-destructive methods
    Al-Mattarneh, Hashem
    CORROSION SCIENCE, 2016, 105 : 133 - 140
  • [50] Non-destructive analytic method using xrf for determination of provenance of archaeological obsidians from the mediterranean area: A comparison with traditional XRF methods
    De Francesco, A. M.
    Crisci, G. M.
    Bocci, M.
    ARCHAEOMETRY, 2008, 50 : 337 - 350