Whole-body dose from tomotherapy delivery

被引:72
|
作者
Mutic, S [1 ]
Low, DA [1 ]
机构
[1] Edward Mallinckrodt Inst Radiol, Div Radiat Oncol, St Louis, MO 63110 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 42卷 / 01期
关键词
intensity modulated radiation therapy; whole-body dose; tomotherapy;
D O I
10.1016/S0360-3016(98)00199-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To measure whole-body dose in tomotherapy of the head and neck region resulting from internal patient scatter and linear accelerator leakage. Methods and Materials: Treatments are performed using a commercial computer-controlled intensity modulated radiation therapy planning and delivery system (Peacock, NOMOS Corp.) and a 6-MV linear accelerator (Clinac 6/100, Varian Corp.). The patient dose outside the treatment held is measured in a water-equivalent phantom using thermoluminescent dosimetry. The whole-body dose components from internal scatter and leakage are separately determined. The use of fixed-portal leakage and scattered radiation measurements to estimate the whale-body dose from tomotherapy is evaluated. Results: The internally scattered dose is significant near the target, but becomes negligible relative to the leakage dose beyond 15 cm from the target. Dose at 10 cm from the target volume, due to internal scatter and leakage, is approximately 2.5% of the total target dose, reducing to 0.5% at 30 cm. The measured dose is relatively uniform throughout the phantom, Conclusion: The whole-body dose equivalent from a tomotherapy treatment is greater than that from conventional. radiation therapy. Further studies are required to assess the trade-off between improved dose distribution conformality and a possible slight increase in radiation-induced fatal malignancies. The accuracy of using fixed-portal leakage and scattered dose measurements to estimate the whole-body dose from tomotherapy treatments is adequate, if the appropriate fixed-portal field size equivalent is used. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 50 条
  • [21] ELECTRON WHOLE-BODY TREATMENT DOSE ANALYSIS OF STANFORD TECHNIQUE
    KAO, M
    LANZL, LH
    ROZENFELD, M
    KRAMER, T
    CHUNGBIN, A
    MEDICAL PHYSICS, 1984, 11 (03) : 379 - 379
  • [22] ANALYSIS OF DOSE DISTRIBUTIONS IN WHOLE-BODY SUPERFICIAL ELECTRON THERAPY
    BJARNGARD, BE
    CHEN, GTY
    PIONTEK, RW
    SVENSSON, GK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (3-4): : 319 - 324
  • [23] DOSE-SURVIVAL TIME RESPONSE OF SUNCUS MURINUS FROM WHOLE-BODY IRRADIATION
    TSUBOUCHI, S
    KANO, E
    ODA, S
    JOURNAL OF RADIATION RESEARCH, 1984, 25 (03) : 234 - 245
  • [24] WHOLE-BODY TRANSMISSION-EMISSION SCANNING WITH WHOLE-BODY CAMERA
    SUZUKI, Y
    MORI, H
    MICHIGISHI, T
    HISADA, K
    MATSUDAIRA, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1975, 125 (04) : 978 - 980
  • [25] CLINICAL WHOLE-BODY COUNTING - WHOLE-BODY SCANNER WITH 2 CRYSTALS
    REIZENSTEIN, P
    KARLSSON, HA
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1966, 4 (03): : 209 - +
  • [26] Whole-body MRI
    Schlemmer, H.
    EJC SUPPLEMENTS, 2007, 5 (04): : 7 - 7
  • [27] WHOLE-BODY BREATHING
    VANDIXHOORN, J
    BIOLOGICAL PSYCHOLOGY, 1990, 30 (03) : 289 - 290
  • [28] WHOLE-BODY PLETHYSMOGRAPH
    不详
    BRITISH MEDICAL JOURNAL, 1968, 3 (5621): : 799 - &
  • [29] A whole-body mystery
    Klein, Alice
    NEW SCIENTIST, 2023, 246 (3423) : 42 - 45
  • [30] Whole-Body Control
    Moro, Federico L.
    Sentis, Luis
    Park, Jaeheung
    Atkeson, Christopher G.
    Gienger, Michael
    Goswami, Ambarish
    Kajita, Shuuji
    Khatib, Oussama
    Kuffner, James
    Orin, David E.
    Ott, Christian
    Pratt, Jerry E.
    Righetti, Ludovic
    Siciliano, Bruno
    Tedrake, Russ
    Yoshida, Eiichi
    IEEE ROBOTICS & AUTOMATION MAGAZINE, 2017, 24 (03) : 11 - 13