Simulation and fabrication of poly methyl methacrylate infrared lenses

被引:0
|
作者
Tsui, Chun-Chao [1 ]
Su, Guo-Dung J. [1 ]
机构
[1] Natl Taiwan Univ, Grad Inst Photon & Optoelect, Taipei 106, Taiwan
关键词
Infrared thermography; infrared rays; PMMA; polymer; low-cost; simulation; MEMS; Fresnel lens; PMMA;
D O I
10.1117/12.893211
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Infrared thermography is a promising solution that can help improve our lives. However, most of the common materials used to fabricate lenses, such as glass, are opaque in the infrared range. Silicon and germanium are better solutions. But shaping these two materials are truly complicated and time-consuming. Many research works have been devoted to develop cost-effective infrared lenses. Due to material restriction, traditional lenses to focus infrared light are expensive. On the other hand, we found that PMMA (Poly methyl methacrylate) is an ubiquitous polymer material. It is cheap and transparent in mid-IR range. More importantly, liquid PMMA can be shaped and solidified easily. Therefore, we chose PMMA as the material to design and make our IR lenses. In this paper, we choose PMMA and discuss its optical properties in mid-IR range. We believe that PMMA is a highly potential material for low-cost infrared lenses. Also, we show simulation results of an f/1.39, diameter = 11mm and focal length = 13.9mm Fresnel lens made by PMMA to demonstrate its feasibility. We made a PMMA Fresnel lens, by using MEMS processes and embossing. The experimental results agree well with simulation data.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] COMPARISON OF THE OPTICAL AND VISUAL QUALITY OF POLY(METHYL METHACRYLATE) AND SILICONE INTRAOCULAR LENSES
    KNORZ, MC
    LANG, A
    HSIA, TC
    POEPEL, B
    SEIBERTH, V
    LIESENHOFF, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06): : 766 - 771
  • [22] Effect of vancomycin on Staphylococcus epidermidis adherence to poly(methyl methacrylate) intraocular lenses
    Das, T
    Sharma, S
    Muralidhar, AV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 703 - 708
  • [23] HAPTIC BREAKAGE IN ONE-PIECE POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    AINSWORTH, JR
    SPENCER, AF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (06): : 863 - 864
  • [24] LACUNARITY PROPERTIES OF NANOPHOTONIC MATERIALS BASED ON POLY(METHYL METHACRYLATE) FOR CONTACT LENSES
    Tomic, Marija
    Bojovic, Bozica
    Stamenkovic, Dragomir
    Mileusnic, Ivana
    Koruga, Djuro
    MATERIALI IN TEHNOLOGIJE, 2017, 51 (01): : 145 - 151
  • [25] Poly(methyl methacrylate) as for microelectromechanical masking material system (MEMS) fabrication
    Bodas, Dhananjay S.
    Gangal, S. A.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 102 (03) : 2094 - 2098
  • [26] Fabrication of hollow capsules composed of poly(methyl methacrylate) stereocomplex films
    Kida, Toshiyuki
    Mouri, Masataka
    Akashi, Mitsuru
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (45) : 7534 - 7536
  • [27] Fabrication and characterization of carbon nanotube reinforced poly(methyl methacrylate) nanocomposites
    Yu, Suzhu
    Juay, Yang Kang
    Young, Ming Shyan
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (04) : 1852 - 1857
  • [28] Fabrication of superhydrophilic and antireflective silica coatings on poly(methyl methacrylate) substrates
    Geng, Zhi
    He, Junhui
    Xu, Ligang
    MATERIALS RESEARCH BULLETIN, 2012, 47 (06) : 1562 - 1567
  • [29] MISCIBILITY OF POLY(METHOXYMETHYL METHACRYLATE) AND POLY(METHYLTHIOMETHYL METHACRYLATE) WITH POLY(METHYL METHACRYLATE)
    GOH, SH
    LEE, SY
    POLYMER BULLETIN, 1990, 23 (06) : 643 - 646
  • [30] Surface modification of poly(methyl methacrylate) used in the fabrication of microanalytical devices
    Henry, AC
    Tutt, TJ
    Galloway, M
    Davidson, YY
    McWhorter, CS
    Soper, SA
    McCarley, RL
    ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5331 - 5337