Direct electrochemistry and electrocatalysis of hemoglobin immobilized on an interlaced Co(OH)2 nanosheet-based three-dimensional macroporous film

被引:8
|
作者
Xie, Qing [1 ]
Chen, Xu [1 ]
Liu, Haimei [1 ]
Yang, Wensheng [1 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing 100029, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Co(OH)(2) nanosheet; Three-dimensional macroporous film; Cathodic electrodeposition; Biosensor; Direct electron transfer; GLASSY-CARBON ELECTRODE; MEDIATOR-FREE BIOSENSOR; HORSERADISH-PEROXIDASE; OXIDE NANOPARTICLES; DIRECT VOLTAMMETRY; COMPOSITE; MICROSPHERES; TEMPERATURE; FABRICATION; CAPACITORS;
D O I
10.1016/j.snb.2012.04.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hemoglobin (Hb) has been successfully immobilized on a glassy carbon (GC) electrode modified by an interlaced Co(OH)(2) nanosheet-based three-dimensional (3D) macroporous film prepared by a cathodic electrodeposition method. The surface morphology of the Co(OH)(2) film was examined by scanning electron microscopy. UV-vis spectra revealed that the Hb immobilized on the Co(OH)(2) film retained its native structure. A fast direct electron transfer was achieved between Hb and the underlying electrode, with an average electron transfer rate of 7.8 s(-1). The resulting biosensor exhibited good performance for the detection of H2O2, with a wide linear range from 0.4 to 200 mu M, low detection limit of 0.2 mu M, high sensitivity of 744 mu A mM(-1) cm(-2), excellent stability and reproducibility. The cathodic electrodeposition method provides a simple and efficient way to prepare a 3D nanostructured film for immobilizing protein or enzyme, and the resulting film has potential applications in biosensors, catalytic bioreactors, and biomedical devices. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [31] Direct electrochemistry and electrocatalysis of hemoglobin based on poly(diallyldimethylammonium chloride) functionalized graphene sheets/room temperature ionic liquid composite film
    Liu, Kunping
    Zhang, Jingjing
    Yang, Guohai
    Wang, Chunming
    Zhu, Jun-Jie
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (03) : 402 - 405
  • [32] Direct Electrochemistry and Electrocatalysis of Hemoglobin Based on Nafion-Room Temperature Ionic Liquids-Multiwalled Carbon Nanotubes Composite Film
    Zhang Ya
    Zheng Jianbin
    CHINESE JOURNAL OF CHEMISTRY, 2011, 29 (04) : 685 - 690
  • [33] Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film
    Wang, QL
    Lu, GX
    Yang, BJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01): : 50 - 57
  • [34] Direct electrochemistry of hemoglobin immobilized in the sodium alginate and SiO2 nanoparticles bionanocomposite film on a carbon ionic liquid electrode
    W. Sun
    D. Wang
    Z. Zhai
    R. Gao
    K. Jiao
    Journal of the Iranian Chemical Society, 2009, 6 : 412 - 419
  • [35] A novel nitrite biosensor based on the direct electrochemistry of hemoglobin immobilized on MXene-Ti3C2
    Liu, Hui
    Duan, Congyue
    Yang, Chenhui
    Shen, Wanqiu
    Wang, Fen
    Zhu, Zhenfeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 218 : 60 - 66
  • [36] Direct Electrochemistry of Hemoglobin Immobilized in the Sodium Alginate and SiO2 Nanoparticles Bionanocomposite Film on a Carbon Ionic Liquid Electrode
    Sun, W.
    Wang, D.
    Zhai, Z.
    Gao, R.
    Jiao, K.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2009, 6 (02) : 412 - 419
  • [37] Ultrathin and Porous NiCo2O4 Nanosheet-Based Three-Dimensional Hierarchical Electrode Materials for High-Performance Asymmetric Supercapacitor
    Ren, Fuyong
    Tong, Zhixiang
    Tan, Shufen
    Yao, Junnan
    Pei, Lijun
    Ji, Yajun
    Abulizi, Abulikemu
    JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2022, 19 (01)
  • [38] Supercapacitance Performances of Electrodeposited Co(OH)2/three-dimensional Graphene Nanocomposite
    Weng, Wenju
    Zou, Ruyi
    Wang, Wencheng
    Luo, Guiling
    Xie, Hui
    Yin, Chunxiao
    Wang, Shaoyu
    Li, Guangjiu
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10601 - 10611
  • [39] Amperometric carbohydrate antigen 19-9 immunosensor based on three dimensional ordered macroporous magnetic Au film coupling direct electrochemistry of horseradish peroxidase
    Zhang, Qi
    Chen, Xiaojun
    Tang, Yin
    Ge, Lingna
    Guo, Buhua
    Yao, Cheng
    ANALYTICA CHIMICA ACTA, 2014, 815 : 42 - 50
  • [40] Nonenzymatic Hydrogen Peroxide Sensor Based on Three-dimensional Ordered Macroporous Gold Film Modified Electrode
    Xuan Jie
    Jiang Li-Ping
    Zhu Jun-Jie
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 513 - 516