Microelectrode arrays: application in batch-injection analysis

被引:31
|
作者
Fungaro, DA
Brett, CMA [1 ]
机构
[1] Univ Coimbra, Dept Quim, P-3049 Coimbra, Portugal
[2] Univ Sao Paulo, IPEN CNEN SP, Div Quim Ambiental, BR-05508900 Sao Paulo, Brazil
关键词
microelectrodes; microelectrode arrays; RAM electrodes; batch-injection analysis; trace metals; anodic stripping voltammetry;
D O I
10.1016/S0003-2670(98)00699-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of microelectrode arrays in electrochemical batch-injection analysis, injection volumes less than or equal to 100 mu l, has been investigated using a random array of microdisks (RAM) electrode made with carbon fibres, Preliminary batch-injection experiments involving hexacyanoferrate(II) oxidation, using fixed-potential amperometry and cyclic voltammetry, showed the expected lesser dependence on injection flow rate and the steady-stare current characteristics of the RAM electrode, compared to results from similar experiments at macroelectrodes. After electrodepositing mercury on the carbon fibre disks, square wave anodic stripping voltammetry of the test of heavy metals zinc, cadmium and lead was carried out by batch-injection analysis, It was found that the accumulation time of the metals influenced the response to a greater extent than at macroelectrodes, that the influence on the injected volume was similar to that at macroelectrodes and the influence of injection flow rate was less. Detection limits are improved at the RAM electrode; sensitivity as a function of normalised electrode area is also enhanced. Experiments in which the RAM electrode was covered by a thin Nafion film before carrying out BLA-SWASV were also performed, and showed similar trends. Although BIA can be performed directly on real samples without added electrolyte, the combination with microelectrodes, which by themselves permit measurements in highly resistive media and fast scan rates, may prove to be very valuable in extreme situations. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
  • [21] AMPEROMETRIC DETECTION UNDER BATCH-INJECTION ANALYSIS CONDITIONS OF CAFFEINE ON AN ELECTRODE MODIFIED BY MIXED-VALENCE IRIDIUM AND RUTHENIUM OXIDES
    Shaidarova, L. G.
    Chelnokova, I. A.
    Degteva, M. A.
    Makhmutova, G. F.
    Leksina, Yu. A.
    Gedmina, A. V.
    Budnikov, G. K.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2016, 49 (10) : 711 - 714
  • [22] Batch-Injection Amperometric Determination of Caffeine and Theophylline on an Electrode Modified by Carbon Nanotubes and Ruthenium Oxides
    L. G. Shaidarova
    I. A. Chelnokova
    M. A. Il’ina
    G. F. Makhmutova
    F. F. Akhmatkhanova
    H. C. Budnikov
    Journal of Analytical Chemistry, 2020, 75 : 1066 - 1071
  • [23] Couple batch-injection analysis and microfluidic paper-based analytical device: A simple and disposable alternative to conventional BIA apparatus
    Arantes, Iana V. S.
    Paixao, Thiago R. L. C.
    TALANTA, 2022, 240
  • [24] Amperometric Detection Under Batch-Injection Analysis Conditions of Caffeine on an Electrode Modified by Mixed-Valence Iridium and Ruthenium Oxides
    L. G. Shaidarova
    I. A. Chelnokova
    M. A. Degteva
    G. F. Makhmutova
    Yu. A. Leksina
    A. V. Gedmina
    G. K. Budnikov
    Pharmaceutical Chemistry Journal, 2016, 49 : 711 - 714
  • [25] Structural Analysis of Explanted Microelectrode Arrays
    Gilgunn, Peter J.
    Ong, Xiao Chuan
    Flesher, Sharlene N.
    Schwartz, Andrew B.
    Gaunt, Robert A.
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 719 - 722
  • [26] High-throughput amperometric determination of tetracycline residues in milk and quality control of pharmaceutical formulations: flow-injection versus batch-injection analysis
    Faria, Lucas, V
    Lima, Ana P.
    Araujo, Fausto M.
    Lisboa, Thalles P.
    Matos, Maria A. C.
    Munoz, Rodrigo A. A.
    Matos, Renato C.
    ANALYTICAL METHODS, 2019, 11 (41) : 5328 - 5336
  • [27] Batch-injection Amperometric Analysis on Screen-printed Electrodes: Analytical System for High-throughput Determination of Pharmaceutical Molecules
    Stefano, Jessica S.
    Dias, Aline C.
    Arantes, Iana V. S.
    Costa, Brenda M. C.
    Silva, Luiz A. J.
    Richter, Eduardo M.
    Banks, Craig E.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2019, 31 (03) : 518 - 526
  • [28] Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
    Cardoso, Rafael M.
    Dornellas, Rafael M.
    Lima, Ana P.
    Montes, Rodrigo H. O.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (09) : 1650 - 1656
  • [29] Editorial on the Special Issue on Microelectrode Arrays and Application to Medical Devices
    Salari, Alinaghi
    Dalton, Colin
    MICROMACHINES, 2020, 11 (08)
  • [30] Electrochemical studies of diamond microelectrode arrays: Application for the detection of pyocyanin
    Alicea, Abneil
    Swain, Greg
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251