Microelectrode arrays: application in batch-injection analysis

被引:31
|
作者
Fungaro, DA
Brett, CMA [1 ]
机构
[1] Univ Coimbra, Dept Quim, P-3049 Coimbra, Portugal
[2] Univ Sao Paulo, IPEN CNEN SP, Div Quim Ambiental, BR-05508900 Sao Paulo, Brazil
关键词
microelectrodes; microelectrode arrays; RAM electrodes; batch-injection analysis; trace metals; anodic stripping voltammetry;
D O I
10.1016/S0003-2670(98)00699-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of microelectrode arrays in electrochemical batch-injection analysis, injection volumes less than or equal to 100 mu l, has been investigated using a random array of microdisks (RAM) electrode made with carbon fibres, Preliminary batch-injection experiments involving hexacyanoferrate(II) oxidation, using fixed-potential amperometry and cyclic voltammetry, showed the expected lesser dependence on injection flow rate and the steady-stare current characteristics of the RAM electrode, compared to results from similar experiments at macroelectrodes. After electrodepositing mercury on the carbon fibre disks, square wave anodic stripping voltammetry of the test of heavy metals zinc, cadmium and lead was carried out by batch-injection analysis, It was found that the accumulation time of the metals influenced the response to a greater extent than at macroelectrodes, that the influence on the injected volume was similar to that at macroelectrodes and the influence of injection flow rate was less. Detection limits are improved at the RAM electrode; sensitivity as a function of normalised electrode area is also enhanced. Experiments in which the RAM electrode was covered by a thin Nafion film before carrying out BLA-SWASV were also performed, and showed similar trends. Although BIA can be performed directly on real samples without added electrolyte, the combination with microelectrodes, which by themselves permit measurements in highly resistive media and fast scan rates, may prove to be very valuable in extreme situations. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
  • [1] INJECTION-ANALYSIS FROM FLOW-INJECTION ANALYSIS TO BATCH-INJECTION ANALYSIS
    WANG, J
    MICROCHEMICAL JOURNAL, 1992, 45 (02) : 219 - 224
  • [2] Batch-injection stripping voltammetry of zinc at a gold electrode: application for fuel bioethanol analysis
    Tormin, Thiago Faria
    Diniz Narciso, Laiz Cristina
    Richter, Eduardo Mathias
    Abarza Munoz, Rodrigo Alejandro
    ELECTROCHIMICA ACTA, 2015, 164 : 90 - 96
  • [3] BATCH-INJECTION ATTACHMENT FOR THE HART DSC
    HANSEN, LD
    CRIDDLE, RS
    THERMOCHIMICA ACTA, 1989, 154 (01) : 81 - 88
  • [4] SMALL-VOLUME BATCH-INJECTION ANALYZER
    WANG, J
    CHEN, L
    ANALYST, 1994, 119 (06) : 1345 - 1348
  • [5] A MERCURY SENSOR FOR FLOW-INJECTION AND BATCH-INJECTION ANALYSES
    VLASOV, YG
    ERMOLENKO, YE
    KOLODNIKOV, VV
    IPATOV, AV
    ALMAROK, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 317 - 319
  • [6] ELECTROCHEMICAL OXIDATION OF THE FUNGICIDE DIMOXYSTROBIN AND ITS AMPEROMETRIC DETERMINATION BY BATCH-INJECTION ANALYSIS
    Dornellas, Rafael M.
    Tormin, Thiago F.
    Richter, Eduardo M.
    Aucelio, Ricardo Q.
    Munoz, Rodrigo A. A.
    ANALYTICAL LETTERS, 2014, 47 (03) : 492 - 503
  • [7] Batch-injection analysis with amperometric detection of the DPPH radical for evaluation of antioxidant capacity
    Oliveira, Gracy K. F.
    Tormin, Thiago F.
    Sousa, Raquel M. F.
    de Oliveira, Alberto
    de Morais, Sergio A. L.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    FOOD CHEMISTRY, 2016, 192 : 691 - 697
  • [8] MULTICOMPONENT BATCH-INJECTION ANALYSIS USING AN ARRAY OF ION-SELECTIVE ELECTRODES
    DIAMOND, D
    LU, JM
    CHEN, Q
    WANG, J
    ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 629 - 635
  • [9] Batch-injection stripping voltammetry of metals in fuel bioethanol
    Tormin, Thiago F.
    Narciso, Laiz C. D.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    FUEL, 2014, 117 : 952 - 956
  • [10] Stripping Voltammetry of Trace Metals at Bismuth-Film Electrodes by Batch-Injection Analysis
    Economou, Anastasios
    Voulgaropoulos, Anastasios
    ELECTROANALYSIS, 2010, 22 (13) : 1468 - 1475