Spline-based cardiac motion tracking using velocity-encoded magnetic resonance imaging

被引:14
|
作者
Bergvall, Erik [1 ,2 ]
Hedstrom, Erik [2 ]
Bloch, Karin Markenroth [3 ]
Arheden, Hakan [2 ]
Sparr, Gunnar [1 ]
机构
[1] Univ Lund Hosp, Lund Inst Technol, Ctr Math Sci, S-22185 Lund, Sweden
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] Philips Med Syst, NL-5680 DA Best, Netherlands
关键词
cardiovascular system; image motion analysis; magnetic resonance imaging; spline functions; velocity measurement;
D O I
10.1109/TMI.2008.917244
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper deals with the problem of tracking cardiac motion and deformation using velocity-encoded magnetic resonance imaging. We expand upon an earlier described method and fit a spatiotemporal motion model to measured velocity data. We investigate several different spatial elements both qualitatively and quantitatively using phantom measurements and data from human subjects. In addition, we also use optical flow estimation by the Horn-Schunk method as complementary data in regions where the velocity measurements are noisy. Our results show that it is possible to obtain good motion tracking accuracy in phantoms with relatively few spatial elements, if the type of element is properly chosen. The use of optical flow can correct some measurement artifacts but may give an underestimation of the magnitude of the deformation. In human subjects the different spatial elements perform quantitatively in a similar way but qualitative differences exists, as shown by a semi quantitative visual scoring of the different methods.
引用
收藏
页码:1045 / 1053
页数:9
相关论文
共 50 条
  • [21] Assessment of Pulmonary Arterial Pressure in Children with Congenital Heart Disease by Velocity-Encoded Cine Magnetic Resonance Imaging
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Azuma, Hiroshi
    CIRCULATION, 2012, 126 (21)
  • [22] Impact of aortic stiffness by velocity-encoded magnetic resonance imaging on late gadolinium enhancement to predict cardiovascular events
    Kaolawanich, Yodying
    Boonyasirinant, Thananya
    IJC HEART & VASCULATURE, 2020, 30
  • [24] ASSESSMENT OF CORONARY FLOW RESERVE IN MAN WITH BREATH-HOLD VELOCITY-ENCODED MAGNETIC-RESONANCE-IMAGING
    SAKUMA, H
    BLAKE, LM
    AMIDON, TM
    OSULLIVAN, M
    SZOLAR, DH
    GLOBITS, S
    FURBER, AP
    BERNSTEIN, MA
    FOO, TK
    HIGGINS, CB
    CIRCULATION, 1995, 92 (08) : 1496 - 1496
  • [25] Age-specific changes in left ventricular diastolic function: A velocity-encoded magnetic resonance imaging study
    Ashrafpoor, Golmehr
    Bollache, Emilie
    Redheuil, Alban
    De Cesare, Alain
    Giron, Alain
    Defrance, Carine
    Azarine, Arshid
    Perdrix, Ludivine
    Ladouceur, Magalie
    Diebold, Benoit
    Mousseaux, Elie
    Kachenoura, Nadjia
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 1077 - 1086
  • [26] Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
    Osman, NF
    Kerwin, WS
    McVeigh, ER
    Prince, JL
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1048 - 1060
  • [27] QUANTIFICATION OF COLLATERAL BLOOD-FLOW IN COARCTATION OF THE AORTA BY VELOCITY-ENCODED CINE MAGNETIC-RESONANCE-IMAGING
    STEFFENS, JC
    BOURNE, MW
    SAKUMA, H
    OSULLIVAN, M
    HIGGINS, CB
    CIRCULATION, 1994, 90 (02) : 937 - 943
  • [28] Assessment of Pulmonary Arterial Pressure by Velocity-Encoded Cine Magnetic Resonance Imaging in Children With Congenital Heart Disease
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Murakami, Noboru
    Azuma, Hiroshi
    CIRCULATION JOURNAL, 2013, 77 (12) : 3015 - 3022
  • [29] Age-specific changes in left ventricular diastolic function: A velocity-encoded magnetic resonance imaging study
    Golmehr Ashrafpoor
    Emilie Bollache
    Alban Redheuil
    Alain De Cesare
    Alain Giron
    Carine Defrance
    Arshid Azarine
    Ludivine Perdrix
    Magalie Ladouceur
    Benoît Diebold
    Elie Mousseaux
    Nadjia Kachenoura
    European Radiology, 2015, 25 : 1077 - 1086
  • [30] Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging
    Westenberg, JJM
    Danilouchkine, MG
    Doornbos, J
    Bax, JJ
    van der Geest, RJ
    Labadie, G
    Lamb, HJ
    Versteegh, MIM
    de Roos, A
    Reiber, JHC
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (04) : 767 - 776