Effect of Renal Function on Gadolinium-Related Signal Increases on Unenhanced T1-Weighted Brain Magnetic Resonance Imaging

被引:35
|
作者
Cao, Yan [1 ]
Zhang, Yang [1 ,2 ]
Shih, George [1 ]
Zhang, Yan [1 ]
Bohmart, Andrew [3 ]
Hecht, Elizabeth M. [4 ]
Prince, Martin R. [1 ,4 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, 416 E,55th St, New York, NY 10022 USA
[2] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan, Peoples R China
[3] Cornell Univ, Weill Med Coll, Dept Nephrol, New York, NY 10021 USA
[4] Columbia Coll Phys & Surg, Dept Radiol, New York, NY USA
关键词
dentate nucleus; globus pallidus; gadolinium; MRI; choroid plexus; hemodialysis; NEPHROGENIC SYSTEMIC FIBROSIS; HYPERINTENSE BASAL GANGLIA; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; DENTATE NUCLEUS; CONTRAST AGENTS; MR-IMAGES; GLOBUS-PALLIDUS; GADOPENTETATE DIMEGLUMINE; MACROCYCLIC-AGENTS;
D O I
10.1097/RLI.0000000000000294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to determine if renal function affects signal changes in the deep brain nuclei on unenhanced T1-weighted images after administration of linear gadolinium-based contrast agents (GBCAs). Methods An electronic medical records search of 2 large medical centers identified 25 patients who received linear GBCA while on hemodialysis and had unenhanced T1-weighted images of the brain before and after. The dentate-to-cerebellar peduncle (DCP) ratio, globus pallidus-to-mid thalamus (GPT) ratio, and choroid plexus-to-nearby white matter ratio were measured and compared with 25 age/sex/GBCA exposure-matched control patients with normal or near-normal renal function (estimated glomerular filtration rate >60 mL/min per 1.73 m(2)). Two additional control groups included 13 patients on hemodialysis without GBCA exposure and 13 age/sex-matched patients with estimated glomerular filtration rate greater than 60 mL/min per 1.73 m(2). Results Hemodialysis patients (n = 25) with an average of 1.8 linear GBCA administrations had a 4.9% mean increase (1.00 0.04 vs 1.05 +/- 0.05; P < 0.001) in DCP, which was greater than the 1.6% change (0.99 +/- 0.04 vs 1.00 +/- 0.05; P = 0.08) observed in matched controls (P = 0.01). There was no significant signal change in the DCP ratio in the 13 hemodialysis patients (0.99 +/- 0.04 vs 0.99 +/- 0.04; P = 0.78) and 13 age/sex-matched patients (0.99 +/- 0.02 vs 0.99 +/- 0.03; P = 0.78) who did not receive GBCA. The hemodialysis patients had a baseline GPT that was higher than nondialysis patients (P < 0.001). However, the GPT change after GBCA administration was not significantly different from controls. Increased signal in the choroid plexus on unenhanced T1-weighted images after GBCA administration was noted in hemodialysis patients (0.72 +/- 0.20 vs 0.86 +/- 0.23; P = 0.006); however, a multivariate analysis showed this to be primarily related to hemodialysis (P = 0.003) with only a trend toward relating to GBCA exposure (P = 0.07). Conclusions Hemodialysis patients receiving linear GBCA have greater dentate nucleus signal increases on unenhanced T1-weighted images, suggesting that renal function may affect the rate of gadolinium accumulation in the brain after linear GBCA-enhanced magnetic resonance imaging.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [31] Brain Extraction Method for T1-weighted Magnetic Resonance Scans
    Somasundaram, K.
    Kalaiselvi, T.
    2010 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS (SPCOM), 2010,
  • [32] Effect of gadolinium contrast-enhanced T1-weighted magnetic resonance imaging for detecting extramural venous invasion in rectal cancer
    Liu, Liheng
    Yang, Linke
    Jin, Erhu
    Wang, Zhenchang
    Yang, Zhenghan
    ABDOMINAL RADIOLOGY, 2016, 41 (09) : 1736 - 1743
  • [33] Effect of gadolinium contrast-enhanced T1-weighted magnetic resonance imaging for detecting extramural venous invasion in rectal cancer
    Liheng Liu
    Linke Yang
    Erhu Jin
    Zhenchang Wang
    Zhenghan Yang
    Abdominal Radiology, 2016, 41 : 1736 - 1743
  • [34] Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1345 - 1352
  • [35] Recent myocardial infarction: Assessment with unenhanced T1-weighted MR imaging
    Goldfarb, James W.
    Arnold, Sheeba
    Han, Jing
    RADIOLOGY, 2007, 245 (01) : 245 - 250
  • [36] On the noise in "augmented T1-weighted steady state magnetic resonance imaging"
    Leupold, Jochen
    Kiselev, Valerij G. G.
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [37] Paramagnetic and Superparamagnetic Inorganic Nanoparticles for T1-Weighted Magnetic Resonance Imaging
    Zeng, Leyong
    Wu, Di
    Zou, Ruifen
    Chen, Tianxiang
    Zhang, Jinchao
    Wu, Aiguo
    CURRENT MEDICINAL CHEMISTRY, 2018, 25 (25) : 2970 - 2986
  • [38] Hyponatremia with Loss of High Signal Intensity in the Posterior Pituitary Lobe on T1-weighted Magnetic Resonance Imaging
    Kitagawa, Masayuki
    Yamanaka, Yoshihiro
    Adachi, Toru
    Ito, Junitsu
    Fukase, Kazutoshi
    Ohta, Ikuro
    Katagiri, Tadashi
    INTERNAL MEDICINE, 2017, 56 (23) : 3205 - 3209
  • [39] Erratum to: Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children
    Maria Camilla Rossi Espagnet
    Bruno Bernardi
    Luca Pasquini
    Lorenzo Figà-Talamanca
    Paolo Tomà
    Antonio Napolitano
    Pediatric Radiology, 2017, 47 : 1366 - 1366
  • [40] Increased Delay Between Gadolinium Chelate Administration and T1-Weighted Magnetic Resonance Imaging Acquisition Increases Contrast-Enhancing Tumor Volumes and T1 Intensities in Brain Tumor Patients
    Piechotta, Paula L.
    Bonekamp, David
    Sill, Martin
    Wick, Antje
    Wick, Wolfgang
    Bendszus, Martin
    Kickingereder, Philipp
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 223 - 228