Local Magnetic Shielding of MRI Devices by Superconductive Materials

被引:3
|
作者
Zucca, Mauro [1 ]
Chiampi, Mario [2 ]
Gozzelino, Laura [3 ]
Zilberti, Luca [1 ]
机构
[1] Ist Nazl Ric Metrol, INRIM, Electromagnet Div, I-10135 Turin, Italy
[2] Politecn Torino, Dipartimento Ingn Elettr, I-10129 Turin, Italy
[3] Politecn Torino, Dipartimento Fis, I-10129 Turin, Italy
关键词
Finite element methods; magnetic resonance imaging; magnetic shielding; superconducting materials; DESIGN; ROOM;
D O I
10.1109/TMAG.2011.2149507
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the possibility of using superconductive elements as passive magnetic shields, in order to mitigate the magnetic field in limited regions around magnetic resonance scanners where medical staff could operate. The analysis is performed through the Finite Element Method by assuming a relative permeability close to zero to simulate the behavior of superconductive materials. Some shielding solutions employing superconductive sheets are proposed, also evaluating the disturbance on the field homogeneity in the center of the superconducting MRI. Possible synergies between the superconductive shields and the ferromagnetic elements, employed as hybrid shields or field concentrators, are finally discussed.
引用
收藏
页码:4278 / 4281
页数:4
相关论文
共 50 条
  • [21] Magnetic shielding of a coupled MRI-Linac system
    Steciw, S.
    Stanescu, T.
    Carlone, M.
    Fallone, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2623 - 2623
  • [22] Passive magnetic shielding in MRI-Linac systems
    Whelan, Brendan
    Kolling, Stefan
    Oborn, Brad M.
    Keall, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (07):
  • [23] Superconductive passive microwave devices
    Nagai, Y
    APPLIED SUPERCONDUCTIVITY 1995, VOLS. 1 AND 2: VOL 1: PLENARY TALKS AND HIGH CURRENT APPLICATIONS; VOL 2: SMALL SCALE APPLICATIONS, 1995, 148 : 769 - 774
  • [24] Peculiarities of the Operation of Devices Providing Local Shielding in Welding.
    Fedorenko, G.A.
    Ardentov, V.V.
    Kudoyarov, B.V.
    Avtomaticheskaya Svarka, 1980, (04):
  • [25] Examination of the shielding performance of the open-type magnetic shield for mri by shielding shape
    MRI 用開口型磁気シールドのシールド形状による遮蔽性能の検討
    Kamata, Kiyotaka (kamata@kagoshima-ct.ac.jp), 1600, Institute of Electrical Engineers of Japan (140): : 705 - 710
  • [26] Characterization methods for comprehensive evaluations of shielding materials used in an MRI
    Gross-Weege, Nicolas
    Dey, Thomas
    Gebhardt, Pierre
    Schug, David
    Weissler, Bjoern
    Schulz, Volkmar
    MEDICAL PHYSICS, 2018, 45 (04) : 1415 - 1424
  • [27] MAGNETIC SHIELDING BY SOFT MAGNETIC-MATERIALS IN ALTERNATING MAGNETIC-FIELD
    OKAZAKI, Y
    UENO, K
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1992, 112 (1-3) : 192 - 194
  • [28] Open Screens for Local Magnetic Shielding at Low Frequencies
    Zucca, Mauro
    Gamba, Maurizio
    Fiorillo, Fausto
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)
  • [29] Electromagnetic characterization of conductive magnetic/non-magnetic shielding materials
    Badic, M
    Marinescu, MJ
    Aciu, LE
    EMC 2005: IEEE International Symposium on Electromagnetic Compatibility, Vols 1-3, Proceedings, 2005, : 185 - 189
  • [30] Study of Magnetic Shielding Materials and Fabrication of Magnetic Shield for Superconducting Cavities
    Masuzawa, M.
    Tsuchiya, K.
    Terashima, A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)