Marginal fit of CAD CAM all ceramic inlays - preliminary study

被引:0
|
作者
Goguta, Luciana [1 ]
Topala, Florin [1 ]
Gavrilovici, Andrei [1 ]
Jivanescu, Anca [1 ]
机构
[1] Univ Med & Pharm VBabes Timisoara, Fac Dent, Dept Prosthodont, Timisoara, Romania
关键词
inlay restoration; all-ceramic materials; CAD/CAM; marginal fit; ONLAYS;
D O I
10.1117/12.2280200
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Aim of the study. Marginal fit of the all ceramic chair side CAD CAM inlays evaluation. Materials and methods. Inlay class II standardized preparations were performed on twelve natural teeth (molars) which were adapted and fixed on a typodont. Scanning of the cavities was done (Planmeca FIT) and the milling of the inlays was realized (Planmeca Mill 40). Light body silicone (Fit Checker II, GC, Tokyo, Japan) was injected on the preparations of the typodont model, and then each of the Empress CAD inlays were seated on the abutments under finger pressure, reproducing the clinical situation of the luting process. The marginal gap between the all ceramic inlays and the cavities was measured using microscopic photos of the silicone fit checker between the inlays and the cavities in 12 points/restoration. A calibration scale and imaging computer software (Image J) were used for the measurements. Results The values measured for the occlusal cavity (marginal occlusal) were ranged between 19.026 mu and 139.669 mu and the values for the vertical cavity (marginal cervical) ranged between 69.256 it and 295.091. Marginal openings below 100 mu-120 mu are clinically acceptable so there where some problems regarding the cervical fit. Conclusion Within the limits of this study there were some cases with poor cervical marginal fit. Extensive studies could be useful for more accurate evaluations.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] CAD-CAM CERAMIC INLAYS AND ONLAYS - USING AN INDIRECT TECHNIQUE
    NATHANSON, D
    RIIS, DN
    CATALDO, GL
    ASHAYERI, N
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (04): : 421 - 427
  • [22] In Vitro evaluation of marginal gap of all ceramic inlays.
    Rocha, P
    Araujo, CR
    Araujo, PA
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 962 - 962
  • [23] Marginal Fit of Heat-pressed vs CAD/CAM Processed All-ceramic Onlays Using a Milling Unit Prototype
    Reich, S.
    Gozdowski, S.
    Trentzsch, L.
    Frankenberger, R.
    Lohbauer, U.
    OPERATIVE DENTISTRY, 2008, 33 (06) : 644 - 650
  • [24] The clinical performance of CAD-CAM-generated ceramic inlays - A four-year study
    Heymann, HO
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1996, 127 (08): : 1171 - 1181
  • [25] Marginal and internal fit of CAD/CAM fiber post and cores
    Moustapha, G.
    Alshwaimi, E.
    Silwadi, M.
    Ounsi, H.
    Ferrari, M.
    Salameh, Z.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (01) : 45 - 53
  • [26] Marginal fit and adaptation of ceramic and gold inlays after conventional cementation.
    Hahn, P
    Kappert, HF
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 579 - 579
  • [27] Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions
    Vargas-Corral, Franklin Guillermo
    Vargas-Corral, Americo Ernesto
    Valverde, Miguel Angel Rodriguez
    Bravo, Manuel
    Leal, Juan Ignacio Rosales
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (01): : 57 - 65
  • [28] Influence of resin-coating techniques on the marginal adaptation and the bond strengths of CAD/CAM-fabricated hybrid ceramic inlays
    Kanamori, Yuna
    Takahashi, Rena
    Nikaido, Toru
    Nitta, Hiroshi
    Shimada, Yasushi
    Tagami, Junji
    Kunzelmann, Karl-Heinz
    DENTAL MATERIALS JOURNAL, 2024, 43 (03) : 407 - 414
  • [29] The influence of different cement spaces on the marginal gap of CAD/CAM all-ceramic crowns
    Zhang, Y.
    Dudley, J.
    AUSTRALIAN DENTAL JOURNAL, 2019, 64 (02) : 167 - 174
  • [30] Marginal fidelity of copy-milled and CAD-CAM all-ceramic crowns
    Wolf, C
    Claas, H
    Hüls, A
    Jeong, SM
    Rinke, S
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 803 - 803