Marginal fit of CAD CAM all ceramic inlays - preliminary study

被引:0
|
作者
Goguta, Luciana [1 ]
Topala, Florin [1 ]
Gavrilovici, Andrei [1 ]
Jivanescu, Anca [1 ]
机构
[1] Univ Med & Pharm VBabes Timisoara, Fac Dent, Dept Prosthodont, Timisoara, Romania
关键词
inlay restoration; all-ceramic materials; CAD/CAM; marginal fit; ONLAYS;
D O I
10.1117/12.2280200
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Aim of the study. Marginal fit of the all ceramic chair side CAD CAM inlays evaluation. Materials and methods. Inlay class II standardized preparations were performed on twelve natural teeth (molars) which were adapted and fixed on a typodont. Scanning of the cavities was done (Planmeca FIT) and the milling of the inlays was realized (Planmeca Mill 40). Light body silicone (Fit Checker II, GC, Tokyo, Japan) was injected on the preparations of the typodont model, and then each of the Empress CAD inlays were seated on the abutments under finger pressure, reproducing the clinical situation of the luting process. The marginal gap between the all ceramic inlays and the cavities was measured using microscopic photos of the silicone fit checker between the inlays and the cavities in 12 points/restoration. A calibration scale and imaging computer software (Image J) were used for the measurements. Results The values measured for the occlusal cavity (marginal occlusal) were ranged between 19.026 mu and 139.669 mu and the values for the vertical cavity (marginal cervical) ranged between 69.256 it and 295.091. Marginal openings below 100 mu-120 mu are clinically acceptable so there where some problems regarding the cervical fit. Conclusion Within the limits of this study there were some cases with poor cervical marginal fit. Extensive studies could be useful for more accurate evaluations.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] In vitro study on marginal and internal fit of CAD/CAM all-ceramic crowns
    Nakamura, T
    Tanaka, H
    Kinuta, S
    Akao, T
    Okamoto, K
    Wakabayashi, K
    Yatani, H
    DENTAL MATERIALS JOURNAL, 2005, 24 (03) : 456 - 459
  • [2] Marginal fit of several proximal box designs for CAD/CAM inlays.
    Fasbinder, DJ
    Heys, D
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1433 - 1433
  • [3] Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns
    Nakamura, T
    Dei, N
    Kojima, T
    Wakabayashi, K
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (03) : 244 - 248
  • [4] The Marginal Fit of CAD/CAM Monolithic Ceramic and Metal-Ceramic Crowns
    Freire, Yolanda
    Gonzalo, Esther
    Lopez-Suarez, Carlos
    Suarez, Maria J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (03): : 299 - 304
  • [5] MARGINAL ADAPTATION AND FIT OF ADHESIVE CERAMIC INLAYS
    KREJCI, I
    LUTZ, F
    REIMER, M
    JOURNAL OF DENTISTRY, 1993, 21 (01) : 39 - 46
  • [6] MARGINAL ADAPTABILITY AND FIT OF CERAMIC MILLED INLAYS
    KAWAI, K
    HAYASHI, M
    TORII, M
    TSUCHITANI, Y
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (10): : 1414 - 1419
  • [7] Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems
    Lee, Kyu-Bok
    Park, Charn-Woon
    Kim, Kyo-Han
    Kwon, Tae-Yub
    DENTAL MATERIALS JOURNAL, 2008, 27 (03) : 422 - 426
  • [8] Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    Bindl, A
    Mörmann, WH
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) : 441 - 447
  • [9] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [10] COMPARISON OF MARGINAL FIT AND MICROLEAKAGE OF CERAMIC AND COMPOSITE INLAYS - AN IN-VITRO STUDY
    THORDRUP, M
    ISIDOR, F
    HORSTEDBINDSLEY, P
    JOURNAL OF DENTISTRY, 1994, 22 (03) : 147 - 153