Hyper-spectral imaging system for imaging O2Hb and HHb concentration changes in tissue for various clinical applications

被引:5
|
作者
Klaessens, John H. G. M. [1 ]
de Roode, Rowland [1 ]
Verdaasdonk, Rudolf M. [2 ]
Noordmans, Herke Jan [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Med Technol & Clin Phys, Utrecht, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, Amsterdam, Netherlands
关键词
Spectroscopy; Near Infrared; 2D; IR Thermography; Hemoglobin; Oxygen; NEAR-INFRARED SPECTROSCOPY; SKIN; OXYGENATION; BRAIN;
D O I
10.1117/12.875110
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To observe local variations in temperature, oxygenation and blood perfusion over time, four imaging systems were developed and compared: Two systems consisting of white broadband light source and a CCD camera in combination with a Liquid Crystal Tunable Filter, one in the visual domain, 420-730 nm, and one in the infrared domain, 650-1100 nm. Thirdly, a CCD camera in combination with a software controlled hyper-spectral light source consisting of a panel with 600 LEDs divided in 17 spectral groups in the range from 370 to 880 nm so that specific spectral distributions can be generated at high repetition rate (>1000 Hz) and, fourthly a standard IR thermal camera for comparison. From the acquired images at the selected wavelengths chromophores concentration images of oxy and deoxy hemoglobin can be calculated applying different algorithms. These imaging techniques were applied and compared for various clinical applications: Tumor demarcation, early inflammation, effectiveness of peripheral nerve block anesthesia, and localization of epileptic seizure. The relative changes in oxygenation and temperature could be clearly observed in good correlation with the physiological condition. The algorithms and data collection/processing can be optimized to enable a real-time diagnostic technique.
引用
收藏
页数:10
相关论文
共 34 条
  • [31] Comparison of the CO2, cw Thulium and Diode laser in a thermal imaging model for the optimization of various clinical applications
    Verdaasdonk, Rudolf
    Rem, Alex I.
    van Thoor, Sander
    de Boorder, Tjeerd
    Klaessens, John
    Teichmann, H. -O.
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XVII, 2006, 6084
  • [32] Non-invasive skin oxygenation imaging using a multi-spectral camera system: Effectiveness of various concentration algorithms applied on human skin
    Klaessens, John H. G. M.
    Noordmans, Herke Jan
    de Roode, Rowland
    Verdaasdonk, Rudolf M.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VIII, 2009, 7174
  • [33] Optical absorption tomography for temperature and H2O concentration imaging by a compact photoelectric detecting system combined with twice adaptive algebraic algorithm
    Zhai, Yunchu
    Wang, Fei
    Chi, Yong
    Cen, Kefa
    OPTICAL ENGINEERING, 2022, 61 (03)
  • [34] Experimental determination of detector gain, zero frequency detective quantum efficiency, and spectral compatibility of phosphor screens:: comparison of CsI:Na and Gd2O2S:Tb for medical imaging applications
    Kandarakis, I
    Cavouras, D
    Kanellopoulos, E
    Nomicos, CD
    Panayiotakis, GS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 417 (01): : 86 - 94