Reconstruction of Pulse Wave and Respiration From Wrist Accelerometer During Sleep

被引:8
|
作者
Zschocke, Johannes [1 ,2 ]
Leube, Julian [2 ,3 ]
Glos, Martin [4 ]
Semyachkina-Glushkovskaya, Oxana [5 ]
Penzel, Thomas [4 ,5 ]
Bartsch, Ronny P. [6 ]
Kantelhardt, Jan W. [2 ]
机构
[1] Martin Luther Univ Halle Wittenberg, Inst Med Epidemiol Biometr & Informat IMEBI, Interdisciplinary Ctr Hlth Sci, Halle, Germany
[2] Martin Luther Univ Halle Wittenberg, Inst Phys, D-06099 Halle, Saale, Germany
[3] Univ Wurzburg, Dept Nucl Med, Wurzburg, Germany
[4] Charite Univ Med Berlin, Interdisciplinary Sleep Med Ctr, Berlin, Germany
[5] Saratov NG Chernyshevskii State Univ, Saratov, Russia
[6] Bar Ilan Univ, Dept Phys, Ramat Gan, Israel
关键词
Sleep apnea; Accelerometers; Wrist; Signal reconstruction; Vibrations; Sensors; Reliability; biomedical monitoring; signal reconstruction; pulse waves; respiration; time series analysis; sleep stages; sleep apnea; PHASE SYNCHRONIZATION; CARDIOVASCULAR-DISEASE; RISK; ACTIGRAPHY; APNEA; WORK;
D O I
10.1109/TBME.2021.3107978
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Nocturnal recordings of heart rate and respiratory rate usually require several separate sensors or electrodes attached to different body parts - a disadvantage for at-home screening tests and for large cohort studies. In this paper, we demonstrate that a state-of-the-art accelerometer placed at subjects' wrists can be used to derive reliable signal reconstructions of heartbeat (pulse wave intervals) and respiration during sleep. Methods: Based on 226 full-night recordings, we evaluate the performance of our signal reconstruction methodology with respect to polysomnography. We use a phase synchronization analysis metrics that considers individual heartbeats or breaths. Results: The quantitative comparison reveals that pulse-wave signal reconstructions are generally better than respiratory signal reconstructions. The best quality is achieved during deep sleep, followed by light sleep N2 and REM sleep. In addition, a suggested internal evaluation of multiple derived reconstructions can be used to identify time periods with highly reliable signals, particularly for pulse waves. Furthermore, we find that pulse-wave reconstructions are hardly affected by apnea and hypopnea events. Conclusion: During sleep, pulse wave and respiration signals can simultaneously be reconstructed from the same accelerometer recording at the wrist without the need for additional sensors. Reliability can be increased by internal evaluation if the reconstructed signals are not needed for the whole sleep duration. Significance: The presented methodology can help to determine sleep characteristics and improve diagnostics and treatment of sleep disorders in the subjects' normal sleep environment.
引用
收藏
页码:830 / 839
页数:10
相关论文
共 50 条
  • [41] DISORDERS OF RESPIRATION DURING SLEEP - REPLY
    STAATS, BA
    MAYO CLINIC PROCEEDINGS, 1983, 58 (12) : 839 - 839
  • [42] Electrocardiogram Derived Respiration during sleep
    Furman, GD
    Shinar, Z
    Baharav, A
    Akselrod, S
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 351 - 354
  • [43] PHYSIOLOGY OF RESPIRATION AND CIRCULATION DURING SLEEP
    RASCHE, K
    HOFFARTH, HP
    BAUR, X
    MEDIZINISCHE KLINIK, 1991, 86 (01) : 42 - 45
  • [44] The statistical distribution of wrist movements during sleep
    Gimeno, V
    Sagales, T
    Miguel, L
    Ballarin, M
    NEUROPSYCHOBIOLOGY, 1998, 38 (02) : 108 - 112
  • [45] Detecting Sleep and Nonwear in 24-h Wrist Accelerometer Data from the National Health and Nutrition Examination Survey
    Thapa-Chhetry, Binod
    Arguello, Diego Jose
    John, Dinesh
    Intille, Stephen
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (11) : 1936 - 1946
  • [46] Arousal responses to respiratory events during sleep: the role of pulse wave amplitude
    Bosi, Marcello
    Milioli, Giulia
    Riccardi, Silvia
    Melpignano, Andrea
    Vaudano, Anna E.
    Cortelli, Pietro
    Poletti, Venerino
    Parrino, Liborio
    JOURNAL OF SLEEP RESEARCH, 2018, 27 (02) : 259 - 267
  • [47] EFFECT OF RESPIRATION ON PULSE WAVE VELOCITY MEASUREMENTS IN THE ARM
    Murphy, J.
    Manoharan, G.
    Adgey, A. A. J.
    JOURNAL OF HYPERTENSION, 2010, 28 : E144 - E144
  • [48] Pulse wave transit time for monitoring respiration rate
    Johansson, A.
    Ahlstrom, C.
    Lanne, T.
    Ask, P.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (06) : 471 - 478
  • [49] Pulse wave transit time for monitoring respiration rate
    A. Johansson
    C. Ahlstrom
    T. Lanne
    P. Ask
    Medical and Biological Engineering and Computing, 2006, 44 : 471 - 478
  • [50] Predictability of arousal in mouse slow wave sleep by accelerometer data
    dos Santos Lima, Gustavo Zampier
    Lopes, Sergio Roberto
    Prado, Thiago Lima
    Lobao-Soares, Bruno
    do Nascimento, George C.
    Fontenele-Araujo, John
    Corso, Gilberto
    PLOS ONE, 2017, 12 (05):