Absolute Distance Metrology Using Diode Pumped Nd:YVO4/KTP Green Laser

被引:0
|
作者
Wahhab, Mohamed Abdel [1 ]
Farid, Niveen [1 ]
El-Okr, Mohamed [2 ]
El-Bahrawi, Mohamed [1 ]
机构
[1] NIST, Length & Precis Engn Div, Tersa St,PO 136, Giza 12211, Egypt
[2] Al Azhar Univ, Fac Sci, Phys Dept, PO 11651, Cairo, Egypt
关键词
Optical crystals; frequency doubling; tuneable wavelength; absolute measurement; absolute distance metrology;
D O I
10.21315/jps2019.30.3.1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The paper exploits absolute distance measurement with traceability to the international system (SI) of units of length. In the present work, the diode pumped Nd:YVO4/KTP polarised green laser is used to measure a distance Delta l between two positions without the need for a reference standard. To comprise a synthetic wavelength lambda(s) suitable to the range of the distance, the output wavelength generated by the frequency doubling is shifted by Delta lambda by controlling the injection current, and a set of shifted wavelengths are produced to form lambda(s). The output signal is sent to the interferometer by an optical fibre after being enhanced with a speckle removal unit. The measurement starts by identifying the zero position where no shift in the interference fringes is observed during sweeping the wavelengths, while at the distance Delta l a deviation in the interference pattern is observed. This deviation is analysed by Fourier transformation to extract the phase change Delta phi and determine the distance value. To prove the reliability of absolute distance measuring interferometer, some measurements are made for various ranges with evaluation of both repeatability and uncertainty. The discussed technique can measure 100 mm with uncertainty +/- 16 mu m.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [31] Theoretical and experimental study of a diode-pumped actively Q-switched Nd:YVO4 green laser with periodically poled KTP
    Li, G
    Zhao, S
    Yang, K
    Wu, W
    LASER PHYSICS LETTERS, 2005, 2 (09) : 423 - 428
  • [32] Diode-pumped, Cr:YAG passively Q-switched and mode-locked Nd:YVO4/KTP green laser
    王军营
    郑权
    薛庆华
    檀慧明
    Chinese Optics Letters, 2003, (10) : 604 - 605
  • [33] Field-Sequential Operation of Laser Diode Pumped Nd : YVO4/PPMgLN Microchip Green Laser
    Lu, Yang
    Xu, Qingyang
    Gan, Yi
    Xu, Changqing
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2010, 22 (13) : 990 - 992
  • [34] Diode-pumped Nd:YVO4/Nd:YLF laser at 488 nm
    Li, Y. L.
    Jiang, H. L.
    Ni, T. Y.
    Zhang, T. Y.
    Tao, Z. H.
    Zeng, Y. H.
    LASER PHYSICS, 2011, 21 (04) : 677 - 679
  • [35] Investigation of Nd:YVO4/YVO4 composite crystal and its laser performance pumped by a fiber coupled diode laser
    Zhuo, Zhuang
    Li, Tao
    Li, Xiaomin
    Yang, Hongzhi
    OPTICS COMMUNICATIONS, 2007, 274 (01) : 176 - 181
  • [36] Study of an efficient Nd: YVO4 red light laser pumped by laser diode
    Zhang, H.L.
    Zhu, N.Y.
    Yang, Q.S.
    Yu, X.L.
    Hou, W.
    Xu, Z.Y.
    Wu, B.C.
    Guangxue Xuebao/Acta Optica Sinica, 2001, 21 (03): : 274 - 277
  • [37] Laser-diode end-pumped Nd:YVO4 slab laser
    Yan, Ying
    Zhang, Heng-Li
    Liu, Yang
    Sha, Peng-Fei
    Li, Jing
    Xing, Ji-Chuan
    Xin, Jian-Guo
    Zhang, Huai-Jin
    He, Jing-Liang
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2009, 29 (05): : 377 - 378
  • [38] Bipolarization and multiwavelength diode-pumped Nd:YVO4 microchip laser
    Cai, ZP
    Xu, HY
    Stephan, G
    OPTICS COMMUNICATIONS, 1997, 135 (4-6) : 295 - 299
  • [39] Thermal Effect of Nd:YVO4 by Laser Diode End-Pumped
    Zheng Yibo
    Zhang Lei
    Jia Liping
    Kang Junjian
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND OPTOELECTRONIC INSTRUMENTS, 2009, 7156
  • [40] Ablation studies using a diode-pumped Nd:YVO4 micro-laser
    Pervolaraki, M
    Dyer, PE
    Monk, P
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2004, 79 (4-6): : 849 - 854