Measurement of colonic polyps by radiologists and endoscopists: Who is most accurate?

被引:17
|
作者
Punwani, S. [1 ]
Halligan, S. [1 ]
Irving, P. [2 ]
Bloom, S. [2 ]
Bungay, A. [2 ]
Greenhalgh, R. [1 ]
Godbold, J. [1 ]
Taylor, S. A. [1 ]
Altman, D. G. [3 ]
机构
[1] UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
[2] UCL Hosp, Dept Gastroenterol, London, England
[3] Wolfson Coll Annexe, Ctr Stat Med, Oxford, England
关键词
colon; CT; CT colonography; cancer; colonoscopy; measurment;
D O I
10.1007/s00330-007-0830-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to determine the accuracy of polyp measurement by endoscopy and CT. A colonic phantom was constructed containing 12 simulated polyps of known diameter. Polyp diameter was estimated during endoscopy by two observers independently. The phantom was then scanned using a 64-detector-row machine and diameter estimated by a further two observers independently, using 2D and 3D visualisation methods. All measurements were obtained twice. Bland-Altman statistics were used to assess agreement between observers' estimates and the reference diameter. The mean difference between observers' measurements and the reference diameter was smallest for estimates made using 3D CT (-0.09 mm and -0.03 mm) and greatest for endoscopy (-1.10 mm and -1.19 mm), with 2D CT intermediate. However, 95% limits of agreement were largest for 3D CT estimates (-4.38 mm to 4.20 mm). Estimates by 2D CT consistently overestimated polyp diameter, whereas endoscopy consistently underestimated diameter. In contrast, measurements by 3D CT were a combination of over- and under-estimates, with a tendency for disagreement to increase with the size of the polyp. The effect of observer experience was small and repeatability was best for 2D CT. Measurement error was encountered with all three modalities tested. Estimates made by 2D CT were believed to offer the best compromise overall.
引用
收藏
页码:874 / 881
页数:8
相关论文
共 46 条
  • [21] Colonic polyps: Effect of attenuation of tagged fluid and viewing window on conspicuity and measurement in vitro experiment with porcine colonic specimen
    Slater, Andrew
    Taylor, Stuart A.
    Burling, David
    Gartner, Louise
    Scarth, Julia
    Halligan, Steve
    RADIOLOGY, 2006, 240 (01) : 101 - 109
  • [22] Which method has the most accurate measurement of daily salt intake?
    Golabchi, Allahyar
    Mazoochi, Majid
    Fayyazi, Hamid Reza
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2015, 20 (10): : 1020 - 1020
  • [23] CT colonography: Automated measurement of colonic polyps compared with manual techniques - Human in vitro study
    Taylor, Stuart A.
    Slater, Andrew
    Halligan, Steve
    Honeyfield, Lesley
    Roddie, Mary E.
    Demeshski, Jamshid
    Amin, Hamdam
    Burling, David
    RADIOLOGY, 2007, 242 (01) : 120 - 128
  • [24] CT colonography: effect of computer-aided detection of colonic polyps as a second and concurrent reader for general radiologists with moderate experience in CT colonography
    Thomas Mang
    Luca Bogoni
    Vikram X. Anand
    Dass Chandra
    Andrew J. Curtin
    Anna S. Lev-Toaff
    Gerardo Hermosillo
    Ralph Noah
    Vikas Raykar
    Marcos Salganicoff
    Robert Shaw
    Susan Summerton
    Rafel F.R. Tappouni
    Helmut Ringel
    Michael Weber
    Matthias Wolf
    Nancy A. Obuchowski
    European Radiology, 2014, 24 : 1466 - 1476
  • [25] CT colonography: effect of computer-aided detection of colonic polyps as a second and concurrent reader for general radiologists with moderate experience in CT colonography
    Mang, Thomas
    Bogoni, Luca
    Anand, Vikram X.
    Chandra, Dass
    Curtin, Andrew J.
    Lev-Toaff, Anna S.
    Hermosillo, Gerardo
    Noah, Ralph
    Raykar, Vikas
    Salganicoff, Marcos
    Shaw, Robert
    Summerton, Susan
    Tappouni, Rafel F. R.
    Ringel, Helmut
    Weber, Michael
    Wolf, Matthias
    Obuchowski, Nancy A.
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1466 - 1476
  • [26] Who says bedside glucose measurement is simple (or always accurate)? Reply
    Meynaar, Iwan A.
    van Spreuwel, Margot
    Tangkau, Peter L.
    Dawson, Lilian
    Visser, Steven Sleeswijk
    Rijks, Lode
    Vlieland, Thea Vliet
    CRITICAL CARE MEDICINE, 2010, 38 (03) : 1013 - 1013
  • [27] Combining Autofluorescence Imaging and Narrow-Band Imaging for the Differentiation of Adenomas from Non-Neoplastic Colonic Polyps Among Experienced and Non-Experienced Endoscopists
    van den Broek, Frank J. C.
    van Soest, Ellert J.
    Naber, Anton H.
    van Oijen, Arnoud H. A. M.
    Mallant-Hent, Rosalie Ch
    Bohmer, Clarisse J. M.
    Scholten, Pieter
    Stokkers, Pieter C. F.
    Marsman, Willem A.
    Mathus-Vligen, Elisabeth M. H.
    Curvers, Wouter L.
    Bergman, Jacques J. G. H. M.
    van Eeden, Susanne
    Hardwick, James C. H.
    Fockens, Paul
    Reitsma, Johannes B.
    Dekker, Evelien
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 (06): : 1498 - 1507
  • [28] Estimating the most accurate sonographic measurement in the diagnosis of carpal tunnel syndrome: Which is the best?
    Koroglu, Ozlem
    Kesikburun, Serdar
    Adiguzel, Emre
    Takaynatan, Mehmet Ali
    Ozgul, Ahmet
    TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2019, 65 (02): : 177 - 183
  • [29] Spherical Near-Field Antenna Measurements - The Most Accurate Antenna Measurement Technique
    Breinbjerg, Olav
    2016 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2016, : 1019 - 1020
  • [30] Total hip arthroplasty offset measurement: Is C T scan the most accurate option?
    Pasquier, G.
    Ducharne, G.
    Sariali, Elhadj
    Giraud, F.
    Mouttet, A.
    Durante, E.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (04) : 367 - 375