Measurement of colonic polyps by radiologists and endoscopists: Who is most accurate?

被引:17
|
作者
Punwani, S. [1 ]
Halligan, S. [1 ]
Irving, P. [2 ]
Bloom, S. [2 ]
Bungay, A. [2 ]
Greenhalgh, R. [1 ]
Godbold, J. [1 ]
Taylor, S. A. [1 ]
Altman, D. G. [3 ]
机构
[1] UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
[2] UCL Hosp, Dept Gastroenterol, London, England
[3] Wolfson Coll Annexe, Ctr Stat Med, Oxford, England
关键词
colon; CT; CT colonography; cancer; colonoscopy; measurment;
D O I
10.1007/s00330-007-0830-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to determine the accuracy of polyp measurement by endoscopy and CT. A colonic phantom was constructed containing 12 simulated polyps of known diameter. Polyp diameter was estimated during endoscopy by two observers independently. The phantom was then scanned using a 64-detector-row machine and diameter estimated by a further two observers independently, using 2D and 3D visualisation methods. All measurements were obtained twice. Bland-Altman statistics were used to assess agreement between observers' estimates and the reference diameter. The mean difference between observers' measurements and the reference diameter was smallest for estimates made using 3D CT (-0.09 mm and -0.03 mm) and greatest for endoscopy (-1.10 mm and -1.19 mm), with 2D CT intermediate. However, 95% limits of agreement were largest for 3D CT estimates (-4.38 mm to 4.20 mm). Estimates by 2D CT consistently overestimated polyp diameter, whereas endoscopy consistently underestimated diameter. In contrast, measurements by 3D CT were a combination of over- and under-estimates, with a tendency for disagreement to increase with the size of the polyp. The effect of observer experience was small and repeatability was best for 2D CT. Measurement error was encountered with all three modalities tested. Estimates made by 2D CT were believed to offer the best compromise overall.
引用
收藏
页码:874 / 881
页数:8
相关论文
共 46 条
  • [1] Measurement of colonic polyps by radiologists and endoscopists: Who is most accurate?
    S. Punwani
    S. Halligan
    P. Irving
    S. Bloom
    A. Bungay
    R. Greenhalgh
    J. Godbold
    S. A. Taylor
    D. G. Altman
    European Radiology, 2008, 18 : 874 - 881
  • [2] Accurate measurement of colonic polyps: In the "AI" of the beholder?
    Trasolini, Roberto P.
    Byrne, Michael F.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2021, 33 (06) : 773 - 774
  • [3] MEASUREMENT OF COLONIC POLYPS. IS VISUAL ESTIMATION ACCURATE?
    Woo, J.
    Rozati, H.
    Besherdas, K.
    GUT, 2014, 63 : A125 - A125
  • [4] Endoscopists' estimation of size should not determine surveillance of colonic polyps
    Moug, S. J.
    Vernall, N.
    Saldanha, J.
    McGregor, J. R.
    Balsitis, M.
    Diament, R. H.
    COLORECTAL DISEASE, 2010, 12 (07) : 646 - 650
  • [5] What Is the Most Accurate Method for the Treatment of Diminutive Colonic Polyps? Standard Versus Jumbo Forceps Polypectomy
    Aslan, Fatih
    Cekic, Cem
    Camci, Mehmet
    Alper, Emrah
    Ekinci, Nese
    Akpinar, Zehra
    Alpek, Serkan
    Arabul, Mahmut
    Unsal, Belkis
    MEDICINE, 2015, 94 (15)
  • [6] ENDOSCOPISTS WHO ARE METICULOUS IN THEIR CAECAL IMAGE DOCUMENTATION DETECT MORE POLYPS
    Thoufeeq, M. H.
    Rembacken, B.
    GUT, 2013, 62 : A215 - A215
  • [7] Endoscopic resection of large sessile colonic polyps by specialist and non-specialist endoscopists
    Brooker, JC
    Saunders, BP
    Shah, SG
    Williams, CB
    BRITISH JOURNAL OF SURGERY, 2002, 89 (08) : 1020 - 1024
  • [8] Endoscopic characterization of small colonic polyps: baseline performance of experienced endoscopists is no different to that of medical students
    Basford, Peter
    Brown, James
    Cooper, Sarah
    Bhandari, Pradeep
    ENDOSCOPY INTERNATIONAL OPEN, 2019, 7 (04) : E403 - E411
  • [9] A pilot study comparing commercially available artificial intelligence (AI) with trained endoscopists on classification of colonic polyps
    Lui, Ka Luen Thomas
    Liu, Sze Hang
    Mak, Lung Yi
    Tsui, Wai Man
    Leung, Wai Keung
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 : 134 - 134
  • [10] Is in vivo measurement of size of polyps during colonoscopy accurate?
    Gopalswamy, N
    Shenoy, VN
    Choudhry, U
    Markert, RJ
    Peace, N
    Bhutani, MS
    Barde, CJ
    GASTROINTESTINAL ENDOSCOPY, 1997, 46 (06) : 497 - 502