Low-light-level nonlinear optics with slow light

被引:235
|
作者
Braje, DA [1 ]
Balic, V [1 ]
Yin, GY [1 ]
Harris, SE [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
来源
PHYSICAL REVIEW A | 2003年 / 68卷 / 04期
关键词
D O I
10.1103/PhysRevA.68.041801
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Electromagnetically induced transparency in an optically thick, cold medium creates a unique system where pulse-propagation velocities may be orders of magnitude less than c and optical nonlinearities become exceedingly large. As a result, nonlinear processes may be efficient at low-light levels. Using an atomic system with three, independent channels, we demonstrate a quantum interference switch where a laser pulse with an energy per area of similar to 23 photons pear lambda(2)/ (2pi) causes a 1/e absorption of a second pulse.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] The Illuminometer Based on Low-Light-Level Image intensifier
    Chen Xulang
    Bai Xiaofeng
    Meng Qingyun
    YanBo
    Miao Zhuang
    FIFTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2019, 11023
  • [22] Detector selection is critical for low-light-level applications
    Zimmerman, RJ
    LASER FOCUS WORLD, 2001, 37 (09): : 109 - 110
  • [23] Low-light-level photon switching by quantum interference
    Chen, YF
    Tsai, ZH
    Liu, YC
    Yu, IA
    OPTICS LETTERS, 2005, 30 (23) : 3207 - 3209
  • [24] LOW-LIGHT-LEVEL TV VIEWING SYSTEM FOR OBSERVERS
    GLASPEY, J
    SABOURIN, R
    JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY OF CANADA, 1979, 73 (05) : 306 - 306
  • [25] Low-light-level all-optical switching
    Wang, Chang-Yi
    Chen, Yong-Fan
    Lin, Sheng-Chiun
    Lin, Wei-Hsun
    Kuan, Pei-Chen
    Yu, Ite A.
    OPTICS LETTERS, 2006, 31 (15) : 2350 - 2352
  • [26] Stray Light Analysis and Test of Low-Light-Level Panoramic Imaging System
    Liu, Feng
    Yan, Lei
    Yang, Zijian
    Zhang, Bo
    Han, Kunye
    7TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2014, 9282
  • [27] A low-light-level sensor for medical diagnostic applications
    Perelman, Y
    Ginosar, R
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2001, 36 (10) : 1553 - 1558
  • [28] Low-light-level all-optical switching
    Yn, Ite A.
    Wang, Chang-Yi
    Chen, Yong-Fan
    Lin, Sheng-Chiun
    Lin, Wei-Hsun
    Kuan, Pei-Chen
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 1161 - 1162
  • [29] Photon counting strategies with low-light-level CCDs
    Basden, AG
    Haniff, CA
    Mackay, CD
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2003, 345 (03) : 985 - 991
  • [30] Improving MISR AOD Retrievals With Low-Light-Level Corrections for Veiling Light
    Witek, Marcin L.
    Diner, David J.
    Garay, Michael J.
    Xu, Feng
    Bull, Michael A.
    Seidel, Felix C.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2018, 56 (03): : 1251 - 1268