Analysis of three phase grid failure and Doubly Fed Induction Generator ride-through using crowbars

被引:0
|
作者
Lohde, Ralf [1 ]
Jensen, Simon [1 ]
Knop, Andre [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Inst Power Elect & Elect Drives, D-24143 Kiel, Germany
来源
2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10 | 2007年
关键词
wind energy; doubly fed induction motor; fault handling strategy; wind generator system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Doubly Fed Induction Generators (DFIG) are nowadays widely used in variable speed wind power plants. The behaviour of these machines during grid failure is an important issue, since in case of under voltage of the mains it is not allowed to simply disconnect the turbine but it is mandatory that it keeps on delivering power to the mains supply system. To protect the rotor side converter, a crowbar at the rotor has to be switched on. The performance of an active crowbar during voltage dips is investigated for several parameter sets of machine, resistor and control.
引用
收藏
页码:3659 / 3666
页数:8
相关论文
共 50 条
  • [21] Review of low voltage ride-through technology of doubly-fed induction generator
    Niu, Lele
    Wang, Xiao
    Wu, Linlin
    Yang, Feng
    Xu, Man
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3106 - 3108
  • [22] Brushless doubly fed generator fault ride-through strategy
    Wang Y.-D.
    Su J.-H.
    Wang H.-N.
    Yu H.-R.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2021, 25 (02): : 28 - 36
  • [23] Analysis and Enhancement of Low-Voltage Ride-Through Capability of Brushless Doubly Fed Induction Generator
    Tohidi, Sajjad
    Oraee, Hashem
    Zolghadri, Mohammad Reza
    Shao, Shiyi
    Tavner, Peter
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (03) : 1146 - 1155
  • [24] An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults
    Hu, Sheng
    Lin, Xinchun
    Kang, Yong
    Zou, Xudong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (12) : 3653 - 3665
  • [25] A comprehensive review of fault ride-through capability of wind turbines with grid-connected doubly fed induction generator
    Parameswari, G. Angala
    Sait, H. Habeebullah
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (08):
  • [26] Evaluation of voltage sag ride-through of a doubly fed induction generator wind turbine with series grid side converter
    Flannery, P. S.
    Venkataramanan, G.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1839 - 1845
  • [27] Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators
    Rahimi, Mohsen
    Parniani, Mostafa
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (02) : 184 - 195
  • [28] Power angle control of grid-connected doubly fed induction generator wind turbines for fault ride-through
    Bu, S. Qiqi
    Du, Wenjuan
    Wang, Haifeng F.
    Gao, S.
    IET RENEWABLE POWER GENERATION, 2013, 7 (01) : 18 - 27
  • [29] High voltage ride-through capability using series grid side converter for doubly fed induction generator based wind turbines
    Boukhris, Youness
    El Makrini, Aboubakr
    El Moussaoui, Hassan
    El Markhi, Hassane
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 766 - 771
  • [30] Unbalanced Voltage Sag Ride-Through of A Doubly Fed Induction Generator Wind Turbine with Series Grid Side Converter
    Flannery, Patrick
    Venkataramanan, Giri
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 556 - 563