Cavity beam position monitor system for the Accelerator Test Facility 2

被引:7
|
作者
Kim, Y. I. [1 ]
Ainsworth, R. [2 ]
Aryshev, A. [3 ]
Boogert, S. T. [2 ]
Boorman, G. [2 ]
Frisch, J. [4 ]
Heo, A. [1 ]
Honda, Y. [3 ]
Hwang, W. H. [5 ]
Huang, J. Y. [5 ]
Kim, E-S. [1 ]
Kim, S. H. [5 ]
Lyapin, A. [2 ]
Naito, T. [3 ]
May, J. [4 ]
McCormick, D. [4 ]
Mellor, R. E. [6 ]
Molloy, S. [2 ]
Nelson, J. [4 ]
Park, S. J. [5 ]
Park, Y. J. [5 ]
Ross, M. [7 ]
Shin, S. [5 ]
Swinson, C. [8 ]
Smith, T. [4 ]
Terunuma, N. [3 ]
Tauchi, T. [3 ]
Urakawa, J. [3 ]
White, G. R. [4 ]
机构
[1] Kyungpook Natl Univ, Taegu, South Korea
[2] Univ London, John Adams Inst Royal Holloway, Egham, Surrey, England
[3] Natl Lab High Energy Phys, KEK, Tsukuba, Ibaraki 305, Japan
[4] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA
[5] Pohang Inst Sci & Technol, Pohang Accelerator Lab, Pohang 790600, South Korea
[6] Cornell Univ, Lab Elementary Particle Phys, Ithaca, NY 14853 USA
[7] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[8] Brookhaven Natl Lab, Upton, NY 11973 USA
基金
英国科学技术设施理事会;
关键词
D O I
10.1103/PhysRevSTAB.15.042801
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1 mu m for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Design of the X-band cavity beam position monitor
    Sojeong Lee
    In Soo Ko
    Changbum Kim
    Seunghwan Kim
    Juho Hong
    Heungsik Kang
    Journal of the Korean Physical Society, 2013, 63 : 1322 - 1326
  • [42] Design of the X-band cavity beam position monitor
    Lee, Sojeong
    Ko, In Soo
    Kim, Changbum
    Kim, Seunghwan
    Hong, Juho
    Kang, Heungsik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1322 - 1326
  • [43] Principal Component Analysis of cavity beam position monitor signals
    Kim, Y.I.
    Boogert, S.T.
    Honda, Y.
    Lyapin, A.
    Park, H.
    Terunuma, N.
    Tauchi, T.
    Urakawa, J.
    Journal of Instrumentation, 2014, 9 (02)
  • [44] Electromagnetic design of the RF cavity beam position monitor for the LCLS
    Waldschraidt, G.
    Lill, R.
    Morrison, L.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 3352 - 3354
  • [45] Hi'Beam-A: A Pixelated Beam Monitor for the Accelerator of a Heavy-Ion Therapy Facility
    Zhang, Honglin
    Zhang, Yuezhao
    Yang, Haibo
    Qian, Cheng
    Li, Xianqin
    Sun, Xiangming
    Wang, Dong
    Huang, Ran
    Wang, Yao
    Zhou, Wei
    Niu, Xiaoyang
    Zhao, Chengxin
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (08) : 2081 - 2087
  • [46] Development of an S-band cavity Beam Position Monitor for ATF2
    Heo, A.
    Kim, E. -S.
    Kim, H.
    Son, D.
    Honda, Y.
    Tauchi, T.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [47] Design, test, and calibration of an electrostatic beam position monitor
    Cohen-Solal, Maurice
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2010, 13 (03):
  • [48] Beam halo collimation studies and measurements at the Accelerator Test Facility ATF2
    Fuster-Martinez, N.
    Bambadeb, P.
    Faus-Golfe, A.
    Kubo, K.
    Liu, S.
    Okugi, T.
    Tauchi, T.
    Terunuma, N.
    Wallon, S.
    Yang, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 917 : 31 - 42
  • [49] Measurement of the beam position in the TESLA Test Facility Linac
    Lorenz, R
    Sachwitz, M
    Schreiber, HJ
    Tonisch, F
    PROCEEEDINGS OF THE XVIII INTERNATIONAL LINEAR ACCELERATOR CONFERENCE, VOLS 1 AND 2, 1996, 96 (07): : 527 - 529
  • [50] Beam position monitors in the TESLA test facility Linac
    Lorenz, R
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2631 - 2633