Data quality monitoring for the CMS electromagnetic calorimeter

被引:1
|
作者
Cossutti, F. [3 ]
Della Ricca, G. [3 ,4 ]
Franzoni, G.
Ghezzi, A. [1 ,2 ]
Gobbo, B. [3 ]
机构
[1] Univ Milan, I-20126 Milan, Italy
[2] INFN Milano Bicocca, I-20126 Milan, Italy
[3] Ist Nazl Fis Nucl, I-34127 Trieste, Italy
[4] Univ Trieste, I-34127 Trieste, Italy
关键词
D O I
10.1016/j.nuclphysbps.2007.11.131
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
One of the aims of the CMS design is to construct and operate a very high quality electromagnetic calorimeter. The detector performance will be monitored using applications based on the CMS Data Quality Monitoring (DQM) framework and running on the High-Level Trigger Farm as well as on local DAQ systems. The monitorable quantities are organized into hierarchical structures based on the physics content. The information produced is delivered to client applications according to their subscription requests. The client applications process the received quantities, according to pre-defined analyses, making the results immediately available, and store the results in a database, and in the form of static web pages, for subsequent studies. We describe here the functionalities of the CMS ECAL DQM applications and report about their use in a real environment.
引用
收藏
页码:289 / 290
页数:2
相关论文
共 50 条
  • [1] Data quality monitoring for the CMS electromagnetic calorimeter
    Della Ricca, Giuseppe
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 253 - 256
  • [2] Monitoring the stability of the CMS electromagnetic calorimeter
    Ferri, Federico
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [3] The monitoring system of the electromagnetic calorimeter of CMS
    Verrecchia, P
    NUCLEAR PHYSICS B, 1998, : 71 - 76
  • [5] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. -L.
    Gras, P.
    Mandjavidze, L.
    Busson, P.
    Paganini, P.
    2007 15TH IEEE-NPSS REAL-TIME CONFERENCE, VOLS 1 AND 2, 2007, : 571 - +
  • [6] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. L.
    Gras, P.
    Mandjavidze, I.
    Busson, P.
    Paganini, P.
    JOURNAL OF INSTRUMENTATION, 2008, 3 (02)
  • [7] The CMS Electromagnetic Calorimeter detector control and monitoring system
    Hintz, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 269 - 271
  • [8] The Commissioning of the CMS Electromagnetic Calorimeter Light Monitoring System
    Orimoto, Toyoko J.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1533 - 1535
  • [9] The electromagnetic calorimeter of CMS
    Funk, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 92 - 96
  • [10] The CMS electromagnetic calorimeter
    Bloch, P
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 241 - 249