Ex vivo magnetic resonance angiography to explore placental vascular anatomy

被引:14
|
作者
Chen, Bailiang [1 ,2 ]
Duan, Jie [1 ,3 ]
Chabot-Lecoanet, Anne-Claire [1 ,3 ]
Lu, Huanrong [1 ]
Tonnelet, Romain [4 ]
Morel, Oliver [1 ,3 ]
Beaumont, Marine [1 ,2 ]
机构
[1] Lorraine Univ, IADI, INSERM, U947, 4 Rue Du Morvan, F-54500 Vandoeuvre Les Nancy, France
[2] CIC IT Nancy, INSERM, CIC1433, 4 Rue Du Morvan, F-54500 Vandoeuvre Les Nancy, France
[3] Reg Matern Univ Nancy, 10 Rue Heydenreich, F-54000 Nancy, France
[4] CHRU Nancy, Neurointervent Dept, F-54000 Nancy, France
关键词
Ex vivo MRA; Human placenta; Vascularization morphology; Contrast agent; Morphology characterization; INTRAUTERINE GROWTH RESTRICTION; ANGIOGENESIS; PREECLAMPSIA; ARTERIAL;
D O I
10.1016/j.placenta.2017.08.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: A normal placenta development is crucial for a successful pregnancy. In case of major obstetric complications such as intra-uterine growth restriction, the placental vascularization morphological alteration at macroscopic level is less known than that at microscopic scale. Ex vivo MRA has the potential to visualize whole fresh human placental vasculature fast and efficiently but can be hampered by contrast agent extravasation problem. This study aimed to provide an optimized ex vivo MRA protocol to acquire understanding of global human placenta vasculature morphology. Methods: Six fresh normal human placentas were imaged with two contrast agents (i.e. Gd-chelate and pump oil) using different imaging parameters on a 3T clinical MR scanner (GE). The contrast to noise ratio, signal to noise ratio and enhancement efficiency were assessed in order to decide which contrast agent and imaging protocol was better. In the end, morphology indices were measured based on the 3D vasculature models reconstructed from the placentas imaged with the optimized protocol. Results: With the same imaging parameters, the CNR and the enhancement efficiency of images enhanced with pump oil were superior to those using Gd-chelate. Enhanced by pump oil, an optimized ex vivo MRA protocol was determined, leading to a clear 3D visualization and reconstruction of human placenta vascularization. Discussion: The proposed ex vivo MRA method is easy to manipulate, and can be used to investigate the human placental vasculature morphology. The acquired data are of good quality and can be used for characterization of placenta vascularization morphology. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 50 条
  • [21] Normal anatomy of the developing fetal brain. Ex vivo anatomical-magnetic resonance imaging correlation
    Bendersky, Mariana
    Musolino, Patricia L.
    Rugilo, Carlos
    Schuster, Gustavo
    Sica, Roberto E. P.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2006, 250 (1-2) : 20 - 26
  • [22] In vivo vs. ex vivo magnetic resonance imaging in mice
    MacKenzie-Graham, Allan
    FRONTIERS IN NEUROINFORMATICS, 2012, 6
  • [23] EVALUATION OF THE VASCULAR ANATOMY IN POTENTIAL LIVING KIDNEY DONORS WITH GADOLINIUM ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY: COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND INTRAOPERATIVE FINDINGS
    Asgari, M. A.
    Dadkhah, F.
    Ghadian, A. R.
    Razzaghi, M. R.
    Noorbala, M. H.
    Amini, E.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (06) : 588 - 588
  • [24] MAGNETIC-RESONANCE ANGIOGRAPHY OF HEMODIALYSIS FISTULAS - EVALUATION OF ANATOMY AND FUNCTION
    WALDMAN, GJ
    PATTYNAMA, P
    CHANG, PC
    VERBURGH, CA
    REIBER, JHC
    DEROOS, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 429 - 429
  • [25] Magnetic resonance angiography for free fibula harvest: anatomy and perforator mapping
    Schuderer, J. G.
    Meier, J. K.
    Klingelhoeffer, C.
    Gottsauner, M.
    Reichert, T. E.
    Wendl, C. M.
    Ettl, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (02) : 176 - 182
  • [26] MAGNETIC-RESONANCE ANGIOGRAPHY COMPARED WITH BASIC MAGNETIC-RESONANCE IN INTRACRANIAL VASCULAR DISEASES
    CARRIERO, A
    TARTARO, A
    DRAGANI, M
    IEZZI, A
    PIZZI, CD
    BONOMO, L
    JOURNAL OF NEURORADIOLOGY, 1994, 21 (01) : 30 - 39
  • [27] Non-Contrast-Enhanced and Contrast-Enhanced Magnetic Resonance Angiography in Living Donor Liver Vascular Anatomy
    Liao, Chien-Chang
    Chen, Meng-Hsiang
    Yu, Chun-Yen
    Tsang, Leung-Chit Leo
    Chen, Chao-Long
    Hsu, Hsien-Wen
    Lim, Wei-Xiong
    Chuang, Yi-Hsuan
    Huang, Po-Hsun
    Cheng, Yu-Fan
    Ou, Hsin-You
    DIAGNOSTICS, 2022, 12 (02)
  • [28] ANGIOGRAPHY BY MAGNETIC-RESONANCE IMAGING - DETAILED VASCULAR ANATOMY WITHOUT IONIZING-RADIATION OR CONTRAST-MEDIA
    RAPP, JH
    PAN, XM
    HALE, J
    SHELDON, P
    FELDMAN, R
    KRUPSKI, W
    SHAROKH, Z
    KAUFMAN, L
    SURGERY, 1989, 105 (05) : 662 - 667
  • [29] High resolution magnetic resonance angiography non-invasively reveals mouse strain differences in the cerebrovascular anatomy in vivo
    Beckmann, N
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (02) : 252 - 258
  • [30] The role of magnetic resonance angiography in the assessment of intracranial vascular disease
    Knopp, EA
    NEUROIMAGING CLINICS OF NORTH AMERICA, 1996, 6 (03) : 769 - &