Gait Pattern Identification and Phase Estimation in Continuous Multilocomotion Mode Based on Inertial Measurement Units

被引:15
|
作者
Zhang, Xingxuan [1 ,2 ]
Zhang, Haojian [1 ]
Hu, Jianhua [1 ]
Zheng, Jun [1 ]
Wang, Xinbo [1 ]
Deng, Jieren [1 ,2 ]
Wan, Zihao [1 ,2 ]
Wang, Haotian [1 ,2 ]
Wang, Yunkuan [1 ]
机构
[1] Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100049, Peoples R China
关键词
Gait pattern identification; phase estimate; adaptive oscillators; gait event detector; wearable robots; EXTREMITY EXOSKELETON ROBOT; REAL-TIME ESTIMATE; INTENT RECOGNITION; EVENT DETECTION; OSCILLATOR;
D O I
10.1109/JSEN.2022.3175823
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the field of lower limb exoskeletons, it is essential to accurately estimate the gait phase of humans. Many methods have been proposed to estimate the gait phase, but only a few studies have considered the multi-locomotion mode. This paper proposes a novel inertial measurement unit(IMU)-based method to estimate the gait phase of a pilot in continuous multi-locomotion mode. The method includes gait pattern recognition based on long short-term memory (LSTM), continuous phase estimation based on a dual adaptive frequency oscillator(DAFO), threshold-based toe-off event detection and a rule-based gait phase synchronization module. First, we used the LSTM-based network to identify four gait patterns including standing, level ground walking, upstairs and downstairs. Next, the DAFO was used to obtain the continuous gait phase of the pilot. Then, we detected the gait events in different gait modes. Finally, the continuous gait phase was synchronized according to the gait events. The experimental result shows that the gait pattern classification accuracy using 5 IMUs is 98.58% and the F-1 score reaches 0.9875. The proposed DAFO model can maintain good stability when multiple gait modes are frequently switched, significantly improving the problem of slow convergence and the poor robustness of single adaptive frequency oscillator(SAFO) models. Toe-off gait events of 492 steps are all detected and the average error at the detected gait events in different gait modes is 15.34 +/- 40.58 ms.
引用
收藏
页码:16952 / 16962
页数:11
相关论文
共 50 条
  • [31] Gait Recognition and Assistance Parameter Prediction Determination Based on Kinematic Information Measured by Inertial Measurement Units
    Xiang, Qian
    Wang, Jiaxin
    Liu, Yong
    Guo, Shijie
    Liu, Lei
    BIOENGINEERING-BASEL, 2024, 11 (03):
  • [32] A Wind Estimation Method for Quadrotors using Inertial Measurement Units
    Song, Yao
    Meng, Qing-Hao
    Luo, Bing
    Zeng, Ming
    Ma, Shu-Gen
    Qi, Pei-Feng
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2016, : 426 - 431
  • [33] Reliability of running gait variability measures calculated from inertial measurement units
    Jones, Ben. D. M.
    Wheat, Jon
    Middleton, Kane
    Carey, David L.
    Heller, Ben
    JOURNAL OF BIOMECHANICS, 2025, 180
  • [34] Gait Patterns in Standard Scenarios Using Xsens MTw Inertial Measurement Units
    Loose, Harald
    Orlowski, Katja
    2015 16th International Conference on Research and Education in Mechatronics (REM), 2015, : 296 - 300
  • [35] An Increase in Estimation Accuracy Position Determination of Inertial Measurement Units
    Beran, Ladislav
    Chmelar, Pavel
    Rejfek, Lubos
    2016 INTERNATIONAL CONFERENCE ON MEASUREMENT INSTRUMENTATION AND ELECTRONICS (ICMIE 2016), 2016, 75
  • [36] Concurrent Validity Of Inertial Measurement Units To Measure Joint Angles During Gait
    Vargo, Brendal
    Franklin, Shannon
    Tometich, Nathan
    Chinworth, Susan
    Vallabhajosula, Srikant
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 557 - 558
  • [37] Wearable Inertial Measurement Units for Assessing Gait in Real-World Environments
    Renggli, David
    Graf, Christina
    Tachatos, Nikolaos
    Singh, Navrag
    Meboldt, Mirko
    Taylor, William R.
    Stieglitz, Lennart
    Schmid Daners, Marianne
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [38] Joint Parameter Estimation Using Magneto and Inertial Measurement Units
    Liu, Yu-Tao
    Zhang, Yong-An
    Zeng, Ming
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 2225 - 2230
  • [39] Evaluation of inertial measurement units as a novel method for kinematic gait evaluation in dogs
    Duerr, Felix M.
    Pauls, Alexandra
    Kawcak, Chris
    Haussler, Kevin K.
    Bertocci, Gina
    Moorman, Valerie
    King, Melissa
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 475 - 483
  • [40] Measuring markers of aging and knee osteoarthritis gait using inertial measurement units
    Hafer, Jocelyn F.
    Provenzano, Seraphina G.
    Kern, Kathy L.
    Agresta, Cristine E.
    Grant, John A.
    Zernicke, Ronald F.
    JOURNAL OF BIOMECHANICS, 2020, 99