Authenticity screening of seized whiskey samples using electrophoresis microchips coupled with contactless conductivity detection

被引:21
|
作者
Rezende, Kariolanda C. A. [1 ]
Moreira, Roger Cardoso [1 ]
Lima Logrado, Lucio Paulo [2 ]
Talhavini, Marcio [2 ]
Coltro, Wendell K. T. [1 ,3 ]
机构
[1] Univ Fed Goias, Inst Quim, Campus Samambaia, BR-74690900 Goiania, Go, Brazil
[2] Inst Nacl Criminalist, Dept Policia Fed, Brasilia, DF, Brazil
[3] Inst Nacl Ciencia & Tecnol Bioanalit INCTBio, Campinas, SP, Brazil
关键词
Adulteration; Beverages; Electrochemical detection; Forensic science; Microfluidic devices; CAPILLARY-ELECTROPHORESIS; SCOTCH WHISKEY; ANALYTICAL STRATEGIES; ALCOHOLIC BEVERAGES; MASS-SPECTROMETRY; CHIP; DISCRIMINATION; ADULTERATION; SPIRITS; QUALITY;
D O I
10.1002/elps.201600277
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes for the first time the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection ((CD)-D-4) to investigate the authenticity of seized whiskey samples, which were probably adulterated by simple dilution with tap water. The proposed microfluidic platform was explored for the monitoring of anionic species (Cl- and F-) in both original and tampered samples. The best separations were achieved within 70 s using a running buffer composed of lactic acid and histidine (pH = 5.9). ME-(CD)-D-4 devices were used to analyze samples from three different brands (five samples each). Based on the presence of inorganic anions like Cl-, F-, SO42- and NO2- in different amounts, the authenticity of seized whiskeys was compared to original samples. According to the reported data, the proposed microfluidic platform can be useful to help regulatory authorities in the investigation and monitoring of authenticity of commercialized whiskey beverages.
引用
收藏
页码:2891 / 2895
页数:5
相关论文
共 50 条
  • [31] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [32] Determination of pharmaceuticals classified as emerging pollutants using capillary electrophoresis with capacitively coupled contactless conductivity detection
    Quek, Ngee Mien
    Law, Wai Siang
    Lau, Hiu Fung
    Zhao, Jian Hong
    Hauser, Peter C.
    Li, Sam Fong Yau
    ELECTROPHORESIS, 2008, 29 (17) : 3701 - 3709
  • [33] Fast determination of ethambutol in pharmaceutical formulations using capillary electrophoresis with capacitively coupled contactless conductivity detection
    Fracassi da Silva, Jose Alberto
    de Castro, Nathan Vitorazzi
    de Jesus, Dosil Pereira
    Faria, Adriana F.
    De Souza, Marcus V. N.
    Leal de Oliveira, Marcone Augusto
    ELECTROPHORESIS, 2010, 31 (03) : 570 - 574
  • [34] Rapid Detection of AGs using Microchip Capillary Electrophoresis Contactless Conductivity Detection
    Zhu, Gangzhi
    Bao, Chunjie
    Liu, Wenfang
    Yan, Xingxing
    Liu, Lili
    Xiao, Jian
    Chen, Chuanpin
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) : 9 - 16
  • [35] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [36] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [37] CAPILLARY ELECTROPHORESIS WITH CONTACTLESS CONDUCTIVITY DETECTION FOR AMINO ACID PROFILING OF HUMAN AND URINE SAMPLES
    Madr, Ales
    Cela, Andrea
    Musilova, Jindra
    Zeisbergerova, Marta
    Glatz, Zdenek
    CHEMICKE LISTY, 2013, 107 : S318 - S319
  • [38] Determination of creatine and phosphocreatine in muscle biopsy samples by capillary electrophoresis with contactless conductivity detection
    See, Hong Heng
    Schmidt-Marzinkowski, Julia
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2012, 727 : 78 - 82
  • [39] CAPILLARY ELECTROPHORESIS WITH CONTACTLESS CONDUCTIVITY DETECTION FOR AMINO ACID PROFILING OF HUMAN PLASMA SAMPLES
    Madr, Ales
    Cela, Andrea
    Tomandl, Josef
    Glatz, Zdenek
    CECE 2014: 11TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2014, : 319 - 322
  • [40] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893