A Review of In-Vivo and In-Vitro Real-Time Corrosion Monitoring Systems of Biodegradable Metal Implants

被引:25
|
作者
Chin, Priscilla Yin Yee [1 ]
Cheok, Quentin [1 ]
Glowacz, Adam [2 ]
Caesarendra, Wahyu [1 ]
机构
[1] Univ Brunei Darussalam, Fac Integrated Technol, BE-1410 Gadong, Brunei
[2] AGH Univ Sci & Technol, Dept Automat Control & Robot, Al A Mickiewicza 30, PL-30059 Krakow, Poland
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 09期
关键词
in-vivo; real-time; corrosion monitoring; biodegradable metal implant; biomaterials; orthopedics; biodegradation; MAGNESIUM IMPLANTS; PURITY MAGNESIUM; MG-ALLOYS; BIOCOMPATIBILITY; DEGRADATION; BEHAVIOR; MICRODIALYSIS;
D O I
10.3390/app10093141
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In current modern medicine, biodegradable metal implants are still considered a work-in-progress between the collaborations of both scientists and engineers. As of now, one of the obstacles to this development is monitoring the corrosion rate of the implant. When a biodegradable metal implant (made of Mg, Zn, etc.) is introduced into the harsh environment of the human body, corrosion naturally occurs, causing metal ions to be released which may result in undesired health effects. The released products of the corroding implant can be used to monitor the implant condition. This paper discusses the current real-time corrosion monitoring systems (i.e., electrochemical-, microsensor-, and microdialysis-based) in-vivo and in-vitro. It is acknowledged that the progress in this sector still requires extensive research in order to obtain a desirable monitoring system and it is hoped that this review paper contributes to the research.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] In-Vitro and In-Vivo Diagnostic Techniques for Prostate Cancer: A Review
    McClure, Patrick
    Elnakib, Ahmed
    Abou El-Ghar, Mohamed
    Khalifa, Fahmi
    Soliman, Ahmed
    El-Diasty, Tarek
    Suri, Jasjit S.
    Elmaghraby, Adel
    El-Baz, Ayman
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2014, 10 (10) : 2747 - 2777
  • [22] CLASTOGENICITY OF O-DIANISIDINE IN IN-VITRO AND IN-VIVO SYSTEMS
    HATANAKA, Y
    TOYODA, Y
    KITAGAWA, Y
    MUTATION RESEARCH, 1993, 292 (03): : 265 - 266
  • [23] CYTOGENETIC EFFECTS OF MEBENDAZOLE ON IN-VIVO AND IN-VITRO MAMMALIAN SYSTEMS
    ANTUNES, LMG
    TAKAHASHI, CS
    REVISTA BRASILEIRA DE GENETICA, 1994, 17 (03): : 273 - 276
  • [24] Real-time localized corrosion monitoring in industrial cooling water systems
    Yang, B
    CORROSION, 2000, 56 (07) : 743 - 756
  • [25] Sensitive, Real-Time, and In-Vivo Oxygen Monitoring for Photodynamic Therapy by Multifunctional Mesoporous Nanosensors
    Yang, Zhenlu
    Wen, Jun
    Wang, Qing
    Li, Yanjiao
    Zhao, Ying
    Tian, Yin
    Wang, Xiaofen
    Cao, Xiongfeng
    Zhang, Yunlei
    Lu, Guangming
    Teng, Zhaogang
    Zhang, Longjiang
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (01) : 187 - 194
  • [26] Optical fiber dosimeter for real-time in-vivo dose monitoring during LDR brachytherapy
    Woulfe, P.
    Sullivan, F. J.
    Kam, W.
    O'Keeffe, S.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 4027 - 4036
  • [27] Real-time Monitoring of Rebar Corrosion in Concrete
    He, Hongzhu
    Cui, Yuli
    Shi, Meilun
    NEW MATERIALS, APPLICATIONS AND PROCESSES, PTS 1-3, 2012, 399-401 : 1234 - 1240
  • [28] Real-time corrosion monitoring reduces costs
    Avery, Allen
    HYDROCARBON PROCESSING, 2008, 87 (01): : 17 - 17
  • [29] Real-time in-vivo dosimetry in HDR prostate brachytherapy
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S27 - S28
  • [30] Real-time in-vivo μ-imaging with Medipix2
    Dammer, J.
    Frallicciardi, P. M.
    Jakubek, J.
    Jakubek, M.
    Pospisil, S.
    Prenerova, E.
    Vavrik, D.
    Volter, L.
    Weyda, F.
    Zemek, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 205 - 207