X-ray phase contrast imaging using single absorption coded aperture

被引:5
|
作者
Krejci, Frantisek [1 ,2 ]
Jakubek, Jan [1 ]
Kroupa, Martin [1 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
[2] Czech Tech Univ, Fac Biomed Engn, Kladno 27201, Czech Republic
关键词
X-ray imaging; Phase contrast; Coded aperture; Phase retrivial; Medipix; RESOLUTION;
D O I
10.1016/j.nima.2010.06.161
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method for X-ray phase contrast imaging is proposed in which only one absorption grating (acting in fact as a coded aperture) and a table-top nano-focus X-ray source are used. This method is based on very precise determination of position of the projected pattern downstreaming from the aperture with and without the inspected object directly from the image of the pattern. The technique is successfully demonstrated on the table-top setup equipped with Medipix family detectors and a nano-focus X-ray source (source-to-detector distance < 1 m). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S181 / S184
页数:4
相关论文
共 50 条
  • [31] Elemental x-ray imaging using Zernike phase contrast
    Shao, Qi-Gang
    Chen, Jian
    Wali, Faiz
    Bao, Yuan
    Wang, Zhi-Li
    Zhu, Pei-Ping
    Tian, Yang-Chao
    Gao, Kun
    CHINESE PHYSICS B, 2016, 25 (10)
  • [32] Dynamic imaging of the lungs using x-ray phase contrast
    Lewis, RA
    Yagi, N
    Kitchen, MJ
    Morgan, MJ
    Paganin, D
    Siu, KKW
    Pavlov, K
    Williams, I
    Uesugi, K
    Wallace, MJ
    Hall, CJ
    Whitley, J
    Hooper, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21): : 5031 - 5040
  • [33] Imaging a microfocus X-ray focal spot with a thin coded aperture
    Davis, Graham R.
    Beckenbach, Thomas
    Meyer, Pascal
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [34] New concept of X-ray microscopes with a coded aperture imaging mask
    Matsuoka, Masaru, 1600, JJAP, Minato-ku, Japan (34):
  • [35] Imaging a microfocus X-ray focal spot with a thin coded aperture
    Graham R. Davis
    Thomas Beckenbach
    Pascal Meyer
    Scientific Reports, 12
  • [36] Single grating phase contrast imaging for x-ray microscopy and microtomography
    Bruyndonckx, P.
    Sasov, A.
    Pauwels, B.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [37] Single absorption grating based X-ray phase contrast CT using Timepix detector
    Zemlicka, J.
    Dudak, J.
    Kubanda, D.
    Krejci, F.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [38] Quantitative single-exposure x-ray phase contrast imaging using a single attenuation grid
    Morgan, Kaye S.
    Paganin, David M.
    Siu, Karen K. W.
    OPTICS EXPRESS, 2011, 19 (20): : 19781 - 19789
  • [39] Strategies for efficient and fast wave optics simulation of coded-aperture and other x-ray phase-contrast imaging methods
    Vittoria, Fabio A.
    Diemoz, Paul C.
    Endrizzi, Marco
    Rigon, Luigi
    Lopez, Frances C.
    Dreossi, Diego
    Munro, Peter R. T.
    Olivo, Alessandro
    APPLIED OPTICS, 2013, 52 (28) : 6940 - 6947
  • [40] A sensitive x-ray phase contrast technique for rapid imaging using a single phase grid analyzer
    Morgan, Kaye S.
    Modregger, Peter
    Irvine, Sarah C.
    Rutishauser, Simon
    Guzenko, Vitaliy A.
    Stampanoni, Marco
    David, Christian
    OPTICS LETTERS, 2013, 38 (22) : 4605 - 4608