Optimisation and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries

被引:41
|
作者
Barratt, DC
Davies, AH
Hughes, AD
Thom, SA
Humphries, KN
机构
[1] Univ London Imperial Coll Sci Technol & Med, Sch Med, Dept Clin Pharmacol & Therapeut, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Sch Med, Dept Surg, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Sch Med, Dept Imaging, London, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2001年 / 27卷 / 07期
关键词
three-dimensional ultrasound; magnetic tracking device; carotid artery; accuracy;
D O I
10.1016/S0301-5629(01)00395-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Electromagnetic tracking devices provide a flexible, low cost solution for three-dimensional ultrasound (3-D US) imaging. They are, however, susceptible to interference. A commercial device (Ascension pcBIRD) was evaluated to assess the accuracy in locating the scan probe as part of a digital, freehand 3-D US imaging system aimed at vascular applications. The device was optimised by selecting a measurement rate and filter setting that minimised the mean deviation in repeated position and orientation measurements. Experimental evaluation of accuracy indicated that, overall, absolute errors were small: the RMS absolute error was 0.2 mm (range: -0.7 to 0.5 mm) for positional measurements over translations up to 90 rum, and 0.2 degrees (range: -0.8 to 0.9 degrees) for rotational measurements up to 30 degrees. In the case of position measurements, the absolute errors were influenced by the location of the scanner relative to the scan volume. We conclude that the device tested provides an accuracy sufficient for use within a freehand 3-D US system for carotid artery imaging.
引用
收藏
页码:957 / 968
页数:12
相关论文
共 50 条
  • [31] The EMC Design of Electromagnetic Finvironment Monitor with Three-dimensional High Accuracy
    Wang, Yuchen
    Xu, Xianglian
    Lu, Zhiwu
    Li, Jialiang
    Wang, Jianchao
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 893 - 897
  • [32] Segmented three-dimensional echo-planar flow imaging of the cervical carotid arteries
    Tkach, JA
    Ding, XP
    Ruggieri, PM
    Obuchowski, NA
    Lieber, M
    Masaryk, TJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (07) : 1339 - 1347
  • [33] New single sweep three-dimensional carotid ultrasound in evaluation of carotid plaque volume changes
    Kalashyan, H.
    Becher, H.
    Saqqur, M.
    Khan, K.
    Romanchuk, H.
    Osborne, J.
    Shuaib, A.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 279 - 279
  • [34] Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry
    Pluym, I. D.
    Afshar, Y.
    Holliman, K.
    Kwan, L.
    Bolagani, A.
    Mok, T.
    Silver, B.
    Ramirez, E.
    Han, C. S.
    Platt, L. D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2021, 57 (05) : 798 - 803
  • [35] Three-dimensional Endoscopic Ultrasound with a new electromagnetic sensor device:: Preliminary results.
    Pontes, JM
    Catré, A
    GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : AB174 - AB174
  • [36] Two-channel high-accuracy Holoimage technique for three-dimensional data compression
    Wang, Yajun
    Zhang, Lianxin
    Yang, Sheng
    Ji, Fang
    OPTICS AND LASERS IN ENGINEERING, 2016, 85 : 48 - 52
  • [37] A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints
    Haut, TL
    Hull, ML
    Howell, SM
    JOURNAL OF BIOMECHANICS, 1998, 31 (06) : 571 - 577
  • [38] Three-dimensional forward-viewing intravascular ultrasound imaging of human arteries in vitro
    Gatzoulis, L
    Watson, RJ
    Jordan, LB
    Pye, SD
    Anderson, T
    Uren, N
    Salter, DM
    Fox, KAA
    McDicken, WN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07): : 969 - 982
  • [39] High-Accuracy Three-Dimensional Visible Light Positioning Systems Using Image Sensor
    Liu, Peixi
    Jiang, Rui
    Bai, Ruowen
    Mao, Tianqi
    Quan, Jinguo
    Wang, Zhaocheng
    2018 IEEE 87TH VEHICULAR TECHNOLOGY CONFERENCE (VTC SPRING), 2018,
  • [40] Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis
    Song, Shinjeong
    Heo, Ran
    Lee, Sang-Eun
    Park, Jinki
    Lee, Jinyong
    Kim, Sujin
    Cho, In Jeong
    Chang, Hyuk-Jae
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (12): : 2241 - 2250