Filter quality of pleated filter cartridges

被引:23
|
作者
Chen, Chun-Wan [2 ]
Huang, Sheng-Hsiu [2 ]
Chiang, Che-Ming [3 ]
Hsiao, Ta-Chih [1 ]
Chen, Chih-Chieh [1 ]
机构
[1] Natl Taiwan Univ, Coll Publ Hlth, Inst Occupat Med & Ind Hyg, Taipei 10055, Taiwan
[2] Council Labor Affairs, Inst Occupat Safety & Hlth, Shijr City, Taipei County, Taiwan
[3] Natl Cheng Kung Univ, Dept Archaeol, Tainan 701, Taiwan
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2008年 / 52卷 / 03期
关键词
filter quality factor; optimal pleat count; pleated filter;
D O I
10.1093/annhyg/men008
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The performance of dust cartridge filters commonly used in dust masks and in room ventilation depends both on the collection efficiency of the filter material and the pressure drop across the filter. Currently, the optimization of filter design is based only on minimizing the pressure drop at a set velocity chosen by the manufacturer. The collection efficiency, an equally important factor, is rarely considered in the optimization process. In this work, a filter quality factor, which combines the collection efficiency and the pressure drop, is used as the optimization criterion for filter evaluation. Most respirator manufacturers pleat the filter to various extents to increase the filtration area in the limit space within the dust cartridge. Six sizes of filter holders were fabricated to hold just one pleat of filter, simulating six different pleat counts, ranging from 0.5 to 3.33 pleats cm(-1). The possible electrostatic charges on the filter were removed by dipping in isopropyl alcohol, and the air velocity is fixed at 100 cm s(-1). Liquid dicotylphthalate particles generated by a constant output atomizer were used as challenge aerosols to minimize particle loading effects. A scanning mobility particle sizer was used to measure the challenge aerosol number concentrations and size distributions upstream and downstream of the pleated filter. The pressure drop across the filter was monitored by using a calibrated pressure transducer. The results showed that the performance of pleated filters depend not only on the size of the particle but also on the pleat count of the pleated filter. Based on filter quality factor, the optimal pleat count (OPC) is always higher than that based on pressure drop by about 0.3-0.5 pleats cm(-1). For example, the OPC is 2.15 pleats cm(-1) from the standpoint of pressure drop, but for the highest filter quality factor, the pleated filter needed to have a pleat count of 2.65 pleats cm(-1) at particle diameter of 122 nm. From the aspect of filter quality factor, this study suggests that the respirator manufacturers should add similar to 0.5 pleats cm(-1) to the OPC derived from the generalized correlation curve for pleated filter design based on minimum pressure drop.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [21] Use of filter cartridges in the cement industry
    Rzadki, HJ
    ZKG INTERNATIONAL, 2002, 55 (12): : 62 - +
  • [22] Modeling unsteady filtration performance of pleated filter
    Feng, Zhuangbo
    Long, Zhengwei
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (06) : 626 - 637
  • [23] Fluid dynamics in pleated membrane filter devices
    Dippel, Jannik
    Handt, Sebastian
    Stute, Birgit
    von Lieres, Eric
    Loewe, Thomas
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 267
  • [24] Bacteria control: Testing membrane filter cartridges
    不详
    FILTRATION + SEPARATION, 2012, 49 (05) : 44 - 44
  • [25] Adsorption Efficiency of Respirator Filter Cartridges for Isocyanates
    Gustavsson, Marcus
    Meiby, Elinor
    Gylestam, Daniel
    Dahlin, Jakob
    Spanne, Marten
    Karlsson, Daniel
    Dalene, Marianne
    Skarping, Gunnar
    Tveteras, Bjorn Oscar
    Pedersen, Age Engen
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (04): : 377 - 390
  • [26] Filter cartridges help wine to achieve stability
    不详
    FILTRATION & SEPARATION, 2018, 55 (03): : 14 - 15
  • [27] Bacteria control: Testing membrane filter cartridges
    Kreps, Sabine
    Filtration and Separation, 2012, 49 (05):
  • [28] Experimental Studies of PowerCore Filters and Pleated Filter Baffles
    Dziubak, Tadeusz
    MATERIALS, 2022, 15 (20)
  • [29] Pleated filter design under the dust cake formation
    Chen, DR
    Pui, DYH
    Endo, Y
    AIR FILTRATION CONFERENCE, PROCEEDINGS, 1999, : 143 - 154
  • [30] Numerical study on the design of multi-staged, opposing pulsed-jet cleaning (M-OPJC) for pleated filter cartridges
    Gao, Kangtai
    Chen, Jianwu
    Wu, Quanquan
    Wu, Qing
    Xu, Jingge
    Meng, Dong
    Li, Jianlong
    Wu, Daishe
    Chen, Da-Ren
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 327