Determination of heparin on intraocular lens surfaces by ion chromatography

被引:16
|
作者
Ander, B [1 ]
Karlsson, A [1 ]
Öhrlund, Å [1 ]
机构
[1] Pharmacia AB, Marketed Prod Support, S-75182 Uppsala, Sweden
关键词
lens; intraocular; heparin;
D O I
10.1016/S0021-9673(01)00661-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method has been developed for the determination of heparin on heparin coated PMMA, poly(methyl methacrylate), intraocular lenses. Heparin was hydrolysed to glucosamine and glucuronic acid, and the content of glucosamine was determined using ion chromatography with pulsed amperometric detection. In order to verify that a complete hydrolysis was obtained for the heparin on the coated intraocular lenses, electron spectroscopy for chemical analysis (ESCA) was used for analysing traces of sulphur on the lens surfaces. The sensitivity of the method allows quantitative determination of 150 ng of heparin on one individual lens. The new method was compared to a standard spectrophotometric method, measuring the colour intensity of a heparin toluidine blue complex. Correlation between the methods was shown for samples prepared from PMMA lenses coated with different amounts of heparin. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [21] DETERMINATION OF ANIONS BY ION CHROMATOGRAPHY
    POHLANDT, C
    SOUTH AFRICAN JOURNAL OF CHEMISTRY, 1980, 33 (03) : 87 - 91
  • [22] Determination of glyphosate by ion chromatography
    Zhu, Y
    Zhang, FF
    Tong, CL
    Liu, WP
    JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) : 297 - 301
  • [23] Determination of epichlorohydrin by ion chromatography
    Sarzanini, C
    Bruzzoniti, MC
    Mentasti, E
    JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 251 - 259
  • [24] Ion chromatography using anion exchangers modified with heparin
    Takeuchi, T
    Safni
    Miwa, T
    Hashimoto, Y
    Moriyama, H
    ANALUSIS, 1998, 26 (02) : 61 - 64
  • [25] Determination of inertia forces at an intraocular lens implant during saccades
    Martin, H.
    Bahlke, U.
    Guthoff, R.
    Rheinschmitt, L.
    Schmitz, K. P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 100 - +
  • [26] COMMON-SENSE DETERMINATION OF INTRAOCULAR-LENS POWER
    DREWS, RC
    OPHTHALMIC SURGERY AND LASERS, 1991, 22 (11): : 632 - 637
  • [27] DETERMINATION OF METHYL SULFATE ION BY ION CHROMATOGRAPHY
    RYCHTMAN, AC
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1989, 7 (06): : 508 - &
  • [28] DETERMINATION OF TETRAMETHYLAMMONIUM ION IN SHELLFISH BY ION CHROMATOGRAPHY
    SAITOH, H
    OIKAWA, K
    TAKANO, T
    KAMIMURA, K
    JOURNAL OF CHROMATOGRAPHY, 1983, 281 (DEC): : 397 - 402
  • [29] Effect of heparin in the irrigation solution on postoperative inflammation and cellular reaction on the intraocular lens surface
    Kruger, A
    Amon, M
    Abela-Formanek, C
    Schild, G
    Kolodjaschna, J
    Schauersberger, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (01): : 87 - 92
  • [30] HEPARIN-SURFACE-MODIFIED INTRAOCULAR-LENS IMPLANTATION IN EYES WITH PSEUDOEXFOLIATION SYNDROME
    RAVALICO, G
    TOGNETTO, D
    BACCARA, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05): : 543 - 549