Application of TCR-Type SVC in Power Substation and Electric Arc Furnaces

被引:0
|
作者
Zhao, ZhongYuan [1 ]
Chen, ChiHan [1 ]
Bao, ShunXian [1 ]
Fang, TaiXun [1 ]
Wang, XiaoHong [1 ]
机构
[1] NanJing NARI RELAYS Elect Co Ltd, Nanjing 211102, Peoples R China
关键词
SVC; voltage fluctuation and flicker; harmonic mitigation; electric arc furnace;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The situation at electric arc furnace factory is always severe containing voltage fluctuation and flicker, three-phase imbalance and low power factor. The dynamic var compensator is a good solution to this condition. The svc, with its continuously variable compensation, also safeguards the plant against overcompensation during furnace outages. The svc equipment, offered by NARI-RELAYS, presents a phase-wise open-loop reactive power controller and a three-phase closed-loop power factor control, which are based on high-speed space vector control. The factory system test on physical simulator is implemented, and its open-loop response time is less than 7 milliseconds with closed-loop one less than 25 milliseconds. One electric arc furnace plant engineering is illustrated as an example to show the effects with/without SVC function. Meanwhile, the voltage fluctuation depression is also shown with SVC operation applied in a power substation.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Performance Evaluation of Various Filters for Electric Arc Furnaces Harmonic and Reactive Power Compensation
    Talebi N.
    Foroughi R.
    Subramanyam B.
    Muthubalaji S.
    Journal of The Institution of Engineers (India): Series B, 2023, 104 (05) : 1155 - 1167
  • [42] Designing Static VAr Compensator capacity to enhance power quality in electric arc furnaces
    Asban, Mohammad Reza
    Aghaei, Jamshid
    Niknam, Taher
    Akbari, Mohammad Amin
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2017, 93 (06): : 515 - 525
  • [43] OPTIMIZING THE ARRANGEMENT OF POWER CONDUCTORS IN 3-PHASE ELECTRIC-ARC FURNACES
    MILDE, F
    BRETTHAUER, K
    MEYER, G
    TECHNISCHE MITTEILUNGEN KRUPP FORSCHUNGSBERICHTE, 1983, 41 (01): : 13 - 23
  • [44] A wide nonlinear analysis of reactive power time series related to electric arc furnaces
    Samet, Haidar
    Golshan, M. E. Hamedani
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 36 (01) : 127 - 134
  • [45] Problems in Design and Construction of High Power Transformers for Electric Arc Melting Furnaces.
    Ikanovic, Juso
    1600, (50):
  • [46] Characteristics of primary and secondary power measurements on 3-phase electric arc furnaces
    Riedinger, Dirk
    Bock, Manfred
    MPT Metallurgical Plant and Technology International, 2002, 25 (02): : 60 - 64
  • [47] Hybrid Deep Neural Network Approaches for Power Quality Analysis in Electric Arc Furnaces
    Panoiu, Manuela
    Panoiu, Caius
    MATHEMATICS, 2024, 12 (19)
  • [48] Application of feedfoward neuro-fuzzy networks for current prediction in electric arc furnaces
    Sadeghian, AR
    Lavers, JD
    IJCNN 2000: PROCEEDINGS OF THE IEEE-INNS-ENNS INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOL IV, 2000, : 420 - 425
  • [49] Application of bifurcations theory to assess nonlinear oscillations produced by AC electric arc furnaces
    Medina, A
    Gómez-Martínez, MA
    Fuerte-Esquivel, CR
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1328 - 1328
  • [50] APPLICATION OF FLYWHEEL ENERGY STORAGE SYSTEMS TO THE POWER SUBSTATION FOR THE ELECTRIC RAILWAY.
    Maruyama, N.
    Kawamura, T.
    Energy developments in Japan, 1984, 6 (03): : 207 - 217